Lev-co
LEV-CO
182 N Port Road, Unit 3
Port Perry, Ontario L9L 0B7
App Support: 1-888-512-7173
Office: (905) 831-7001 / (888) 862-5356
Fax: (905) 831-7443 / (866) 885-1583
E-Mail: sales@lev-co.com
Icon for Processes

Steel Welding - Engineering Control Methods

In the steel welding process, welding smoke is generated, which when inhaled, leads to long-term health problems and creates a hazardous, unsafe work environment. Ventilation systems are the answer to limiting hazardous fumes in the work environment.
See a full list of engineering control methods for steel welding below.



For further support, please contact us directly at 1-888-862-5356.

Ambient Air Cleaners
Animated Diagram for Ambient Air Cleaners
At-Source Capture Systems
Back & Side Draft Systems
Animated Diagram for Back & Side Draft Systems
Centrally Ducted Filter Units
Animated Diagram for Centrally Ducted Filter Units
Down Draft Tables
Animated Diagram for Down Draft Tables
Ducted Air Cleaners
Animated Diagram for Ducted Air Cleaners
Dust Control Booths
Animated Diagram for Dust Control Booths
Exhaust Fans & Controls
Animated Diagram for Exhaust Fans & Controls
Extraction Arms
Animated Diagram for Extraction Arms
Industrial Hose & Duct Work

Lev-Co offers a wide variety of lightweight, flexible, abrasive-resistant, heat-tolerant, innovative technical hoses to provide solutions for a wide range of industrial & automotive applications. Here are some general design velocities when using "CAPTURE" Hoods: 

Smoke (e.g. Welding):

  • Capture Velocity 100 FPM
  • Transport Velocity 3000 FPM
  • Minimum Face velocity 2355 FPM


Dust (e.g. Grinding):

  • Capture Velocity 500 FPM
  • Transport Velocity 4000 FPM
  • Minimum Face Velocity 4000 FPM


Gas (e.g. V.O.C.'s):

  • Capture Velocity 50 FPM
  • Transport Velocity 2000 FPM
  • Minimum Face Velocity 785 FPM


Mist:

  • Capture Velocity 100 FPM
  • Transport Velocity 2250 FPM
  • Minimum Face Velocity 1766 FPM


FOR MORE SUPPORT IN SELECTING THE RIGHT HOSE pls EMAIL us with details on your application at: sales@lev-co.com.

Animated Diagram for Industrial Hose & Duct Work
Overhead Filter Systems
Animated Diagram for Overhead Filter Systems
Portable Filter Units
Animated Diagram for Portable Filter Units
Wall/Floor Mounted Filters
Animated Diagram for Wall/Floor Mounted Filters
C6680170AD314948B5E1AD13B8596BA8