Specification Drawings
Case Studies
Solutions
Industries
Processes
Engineering Control Methods
Solutions
- Overhead Filter Systems Learn More
Industries
Aerospace
Auto body repair
Chemicals and Plastics
Educational
Farm & Heavy Equipment
Machine Shop
Metalworking
MRO
Municipal & DOT Garage
National Defense
Vehicle Repair
Waste Management
Welding Shops
Processes
- Buffing and Polishing
- Nickel Welding
- Rubber Manufacturing
- Stainless Welding
- Steel Welding
- Waste Management Facilities
- Welding Shop
Engineering Control Methods
- Extraction Arms with integrated filtration
HC4 - 2000 CFM
The HC4 is a horizontal cartridge collector with (4) Clean-2® cartridge filters (150ft² of media each). It is designed to be used with our Flexi Extraction Arms and allows collected dust to be funneled out the bottom of the collector and into a drum or other storage means.
FUNCTION
CONSTRUCTION
KEY CRITERA
SUITABLE FOR
The HC4 is a collector using a cartridge filtering system. This unit is ideal for limited floor space, as well as high maneuverability.
With the use of our Flexi Extraction Arms, 4 stations can be filtered at any given moment, allowing for maximized productivity and allowing for capture at source extraction.
The unit comes complete with either DUAL inlets or (2) 10’ long E-Z Arm® high flow extractors (with damper and light in the hood), AUTO-CLEAN VIBRA-PULSE® filter cleaning system, a 3 HP TEFC motor, and a ½” NPT regulator, with a nominal flow rate of 2000 CFM.
Options Available:
The unit comes complete with either DUAL inlets or (2) 10’ long E-Z Arm® high flow extractors (with damper and light in the hood), AUTO-CLEAN VIBRA-PULSE® filter cleaning system, a 3 HP TEFC motor, and a ½” NPT regulator, with a nominal flow rate of 2000 CFM.
Options Available:
- Pressure Gauge Kit: Indicates when filters require cleaning.
- Silencer: Reduces noise by 4 dB.
- Custom Cartridge Media: For specific applications.
- 14-ft. E-Z Arm® High Flow Extractors: Replaces standard 10-ft. E-Z Arm® Extractors for peak system performance.
- (2) 8" (200mm)Ø Inlets: Simplifies ducted application installation (less dual arms).
CONSTRUCTION
- Cabinet: 14 and 16ga. steel, powder-coated
- Blower Pkg (HP): 3.0
- Noise Level (dB): 82/78 silencer
- Electrical: 3.0 HP - 208-230/460/3/60, 9.2-8.0/4/3 amps
- Nominal Air Flow (CFM): 2000 @ 60Hz, 1750 @ 50Hz
- Front Access Panel: to AMCA Type B, non-sparking, blower/motor
- (2) Removable End Caps: for easy access to filters
- (2) Hoppers: 7.88” diameter outlets, 4-way
- Airfoil Blade: Adjustable
- Exhaust grille
- Motor: wired to junction box outside unit (Motor starter not included)
KEY CRITERA
- Dual 10-ft. E-Z Arm® High Flow Extractors: Increases collection efficiency over ambient systems
- Class II Direct-Drive Blower: Higher static pressure, longer filter life and greater reliability; spark resistant; no belts or pulleys to replace
- Non-Electrostatic Operation: High reliability, low maintenance
- Vibra-Pulse® Filter Cleaning System: Cleans filters 75% more effectively than reverse pulse systems
- Auto-Clean Off-Line Filter Cleaning: Automatically cleans filters when unit is shut off
SUITABLE FOR
Top 5 contaminants/processes/applications:
IMPORTANT: For your Health and Safety, make sure to talk to an application engineer before purchasing.
- Oil smoke
- Coolant mist
- Smoke
- Dust
- Welding fumes
IMPORTANT: For your Health and Safety, make sure to talk to an application engineer before purchasing.
BASE MODELS, OPTIONS & ACCESSORIES
Part #
Description
HC-4- EZ-ARMS-1
Horizontal cartridge collector with:
- (4) CLEAN-2 ® filter cartridges
- (2) 10’ E-Z Arms & Auto-Clean Off-Line Vibra-Pulse filter cleaning system
- (1) 3 HP TEFC Motor 230-460/3/60 Hz
HC-4- FLEXI-2
Horizontal cartridge collector with:
- (4) CLEAN-2 ® filter cartridges
- (2) 10’ Flexi-I Arms & Auto-Clean Off-Line Vibra-Pulse filter cleaning system
- (1) 3 HP TEFC Motor 575/3/60 Hz
HC-4-DUCTED-1
Horizontal cartridge collector with:
- (4) CLEAN-2 ® filter cartridges
- Auto-Clean Off-Line Vibra-Pulse filter cleaning system
- 3 HP TEFC Motor 230/460/3/60 Hz
- Unit comes complete with (2) duct connections
HC-4-DUCTED-2
Horizontal cartridge collector with:
- (4) CLEAN-2 ® filter cartridges
- Auto-Clean Off-Line Vibra-Pulse filter cleaning system
- 3 HP TEFC Motor 575/3/60 Hz
- Unit comes complete with (2) duct connections
HC-4-EZ-ARMS-2
Horizontal cartridge collector with:
- (4) CLEAN-2 ® filter cartridges
- (2) 10’ E-Z Arms & Auto-Clean Off-Line Vibra-Pulse filter cleaning system
- 3 HP TEFC Motor 575-600/3/60 Hz
HC-4-FLEXI-1
Horizontal cartridge collector with:
- (4) CLEAN-2 ® filter cartridges
- (2) 10’ Flexi-I Arms & Auto-Clean Off-Line Vibra-Pulse filter cleaning system
- 3 HP TEFC Motor 230-460/3/60 Hz
Part #
Description
HC-4-HEPA
External HEPA.
Part #
Description
HC-4-PG-10
0-10" Magnahelic pressure gauge, approximately 5" (125mm)Ø size.
- Surface mounted
LEV-MC-PG-5
Pressure Gauge - complete with Wall, Ceiling, or Table Mounting Bracket, & 0-5" pressure gauge.
3/16 inside diameter tubing ordered separately.
LEV-PG-FM-01
Pressure Gauge 0-5" w.c. - Flush Mount - 01. Mounting kit/retrofit. Complete with pressure gauge, holding plates, tubing, and NPT fittings.
PG-10
Pressure Gauge - complete with Wall, Ceiling, or Table Mounting Bracket & 0-10" pressure gauge. 3/16 inside diameter tubing ordered separately.
Part #
Description
HC-4-7E14
(2) 7 E-Z ARM 14' Long Option for Standard HC-4 Unit
- Wall Bracket must be ordered separately
FREQUENTLY BOUGHT TOGETHER
Part #
Description
HC-4-S-EXT
Exhaust Silencer Option for Standard HC-4 Unit.
Part #
Description
P-025-120S-575V-3PH-20HP
Energy Saver E- Man© 575V/3/60. Fan Motor control station. Rated up to 20 HP. HP. Permits start-stop of the fan / Dustcollector from a Remote Switch/control. Remote mounted switches must be ordered separately but it is best to interlock the fan with the associate process. Comes complete with relevant Motor overload. Please specify Motor HP when ordering ______. Also includes a 50 VA 120V AC transformer for powering the dust collectors sequencer.
Part #
Description
7FR0-2020
Flame Retardant Cartridge Filter made of 80/20% Cell/Poly Blend - Replacement Filter for DCH/PCH/DTH, TC-4, HC-4, DC-4/6/8/12/18 & DT-3000V2 filter units, complete with Vibra Pulse Tube
7FR0-2027
Teflon Filter for DCH/PCH/DTH, TC-4, HC-4, DC-4/6/8/12/18 & DT-3000V2 filter units.
- VIBRA-PULSE tubes included
7FR0-5020
OEM Cartridge Filter ALH-1/2/6 filter used in explosive & flammable applications such as aluminum dust applications.
CHARCOAL-CP20
20 lbs. of CP Blend of chemisorbant and activated carbon blend.
Target Contaminants:
Target Contaminants:
- Hydrocarbons
- VOC's
- Oxides of sulfur
- Formaldehyde
- Nitric Oxide
- Hydrogen Sulfide
- Lower molecular weight
- Aldehydes & organic acids
CHARCOAL-CP40
40 lbs. of CP Blend of chemisorbant and activated carbon blend.
Target Contaminants:
Target Contaminants:
- Hydrocarbons
- VOC's
- Oxides of sulfur
- Formaldehyde
- Nitric Oxide
- Hydrogen Sulfide
- Lower molecular weight
- Aldehydes & organic acids