Lev-co
LEV-CO
182 N Port Road, Unit 3
Port Perry, Ontario L9L 0B7
App Support: 1-888-512-7173
Office: (905) 831-7001 / (888) 862-5356
Fax: (905) 831-7443 / (866) 885-1583
E-Mail: sales@lev-co.com
model_icon

07-004

HC4 Suspended System with Extraction Arms/Self cleaning filters - UPDRAFT & OVERHEAD CAPTURE SYSTEMS

Horizontal cartridge collector w/4 Clean-2® cartridge filters (150ft² of media each).

Designed to be used with our Flexi extraction arms.

Flowrates available from 1000CFM to 2000CFM.

Function:

Our filter cartridge system is an ideal solution for limited floor space, as well as high maneuverability. With the use of our Flexi extraction arms, 4 stations can be filtered at any given moment, allowing for maximized productivity.

Comes complete with either DUAL inlets or (2) 10’ long E-Z Arm® high flow extractors (with damper and light in the hood), AUTO-CLEAN VIBRA-PULSE® filter cleaning system, a 3 HP TEFC motor, and a ½” NPT regulator. 2000 CFM

Options:
  • Pressure Gauge Kit: Indicates when filters require cleaning.
  • Silencer: Reduces noise up to 4 dB.
  • Custom Cartridge Media: For specific applications.
  • 14-ft. E-Z Arm® High Flow Extractors: Replaces standard 10-ft. E-Z Arm® Extractors for peak system performance.
  • (2) 8-in. Dia. Inlets: Simplifies ducted application installation (less dual arms.)

Construction:

Specifications:
  • Construction: 14 and 16ga. steel cabinet, powder-coated
  • Blower Pkg (HP): 3.0
  • Noise Level (dBA): 82/78 silencer
  • Electrical: 3.0 HP - 208-230/460/3/60, 9.2-8.0/4/3 amps
  • Nominal Air Flow (CFM): 2000
  • Front access panel to AMCA Type B, non-sparking, blower/motor
  • 2 removable end caps for easy access to filters
  • 2 hoppers with 7.88” diameter outlets, 4-way
  • Adjustable airfoil blade
  • Exhaust grille
  • motor wired to junction box outside unit (Motor starter not included)

Key Buying Criteria:

  • Dual 10-ft. E-Z Arm® High Flow Extractors: Increases collection efficiency over ambient systems
  • Class II Direct-Drive Blower: Higher static pressure, longer filter life and greater reliability; spark resistant; no belts or pulleys to replace
  • Non-Electrostatic Operation: High reliability, low maintenance
  • Vibra-Pulse® Filter Cleaning System: Cleans filters 75% more effectively than reverse pulse systems
  • Auto-Clean Off-line Filter Cleaning: Automatically cleans filters when unit is shut off
Part #
Qty 
Description
HC-4- EZ-ARMS-1
Horizontal cartridge collector w/(4) Clean 2 filter cartridges (2)10’ E-Z Arms and Auto-Clean Off-Line Vibra-Pulse filter cleaning system and a 3 HP TEFC Motor 230-460/3/60 Hz
HC-4- FLEXI-2
Horizontal cartridge collector w/(4) Clean 2 filter cartridges (2) 10’ Flexi-I Arms and Auto-Clean Off-Line Vibra-Pulse filter cleaning system and a 3 HP TEFC Motor 575/3/60 Hz
HC-4-DUCTED-1
Horizontal cartridge collector w/(4) Clean 2 filter cartridges, Auto-Clean Off-Line Vibra-Pulse filter cleaning system and a 3 HP TEFC Motor 230/460/3/60 Hz. Unit comes c/w 2 duct connections.
HC-4-DUCTED-2
Horizontal cartridge collector w/(4) Clean 2 filter cartridges, Auto-Clean Off-Line Vibra-Pulse filter cleaning system and a 3 HP TEFC Motor 575/3/60 Hz. Unit comes c/w 2 duct connections.
HC-4-EZ-ARMS-2
Horizontal cartridge collector w/(4) Clean 2 filter cartridges (2)10’ E-Z Arms and Auto-Clean Off-Line Vibra-Pulse filter cleaning system and a 3 HP TEFC Motor 575-600/3/60 Hz
HC-4-FLEXI-1
Horizontal cartridge collector w/(4) Clean 2 filter cartridges (2) 10’ Flexi-I Arms and Auto-Clean Off-Line Vibra-Pulse filter cleaning system and a 3 HP TEFC Motor 230-460/3/60 Hz

Frequently bought together these options:

Part #
Qty 
Description
HC-4-HEPA
External HEPA
Part #
Qty 
Description
HC-4-S-EXT
Exhaust Silencer Option for Standard HC-4 Unit
Part #
Qty 
Description
HC-4-PG-10
0-10 magnahelic pressure gauge, approximately 5 diameter size. Surface mounted.
LEV-MC-PG-5
Pressure Gauge - complete with Wall, Ceiling or table mounting bracket and 0-5 pressure gauge. 3/16 inside diameter tubing ordered separately.
PG-10
Pressure Gauge - complete with Wall, Ceiling or table mounting bracket and 0-10 pressure gauge. 3/16 inside diameter tubing ordered separately.
Part #
Qty 
Description
VFD-KIT-1HP-115-230-3
1HP 120-240V Hybrid VFD 1 Phase In, 230V 3 Phase Output 60Hz complete with:
  • VFD NEMA 4
  • 1 HP Motor
  • Able to support HP lower than 1HP
  • Wiring
  • Labor
  • Re-certification
  • PLEASE NOTE: this kit is only required when upgrading a 120V system with a VFD
VFD-KIT-2HP-115-230-3
2HP 120-240V Hybrid VFD 1 Phase In, 230V 3 Phase Output 60Hz complete with:
  • VFD NEMA 4
  • 2 HP Motor
  • Able to support lower HP between 1HP - 2HP
  • Wiring
  • Labor
  • Re-certification
  • PLEASE NOTE: this kit is only required when upgrading a 120 or 220/1/60 V system with a VFD
VFD-KIT-3HP-220-230-3
3HP 240V Hybrid VFD 1 Phase In, 230V 3 Phase Output 60Hz complete with:
  • VFD NEMA 4
  • 3 HP Motor
  • Able to support lower HP between 2HP - 3HP
  • Wiring
  • Labor
  • Re-certification
  • PLEASE NOTE: this kit is only required when upgrading a 120V system with a VFD
Get My Instant Quote
Technical Info Requested