model_icon

07-002

F91 Suspended System with Extraction Arms - Updraft and Overhead Capture Systems

Overhead self-supporting extraction system.

Holds one or two arms extraction arms

Airflow ratings from 650CFM to 1300CFM

Function:

The F91 extraction system offers 2, 3, or 4 stage filtration, and with the use of Ultra-Seal® Filter Mounting, eliminates contaminant bypass of filters.

When paired with our 10' Flexi extraction arm, this system provides source capture, eliminating possible contaminants.

Optional gas adsorption is available to remove gases as well as particulate matter. Washable pre-filters, a primary bag filter, and optional HEPA after-filters combine to provide 99.97% filtration efficiency at noise levels as low as 79 dB.

Includes Class II B.I. blower direct drive, 3 HP motor, 3ø

Options:
  • Pressure Gauge Kit: Indicates when filters require cleaning.
  • Silencer: Reduces noise by 3 dBA.
  • 14-ft. E-Z Arm® High Flow Extractor: Replaces standard 10-ft. E-Z Arm® Extractor for peak system performance.
  • Available Filter Modules: Chevron® mist collector, Disposable 4 pre-filter, 99.97% efficiency HEPA after-filter, multi-filter gas adsorption module.

Construction:

Specifications:
  • Construction: 16 ga. steel cabinet, powder coated
  • Blower Pkg (HP): 3.0
  • Noise Level (dBA): 79
  • Electrical: 3.0 HP - 208/230/460/3/60, 8.0/4.0 amps
  • Nominal Air Flow (CFM): 1300
  • 2” mesh pre-filter, 95% bag main filter

Shipping Dimensions and Weight:

Main System Part # Height x Width x Depth Weight
F91 48"H x 28"W x 91"D 445 lbs

Key Buying Criteria:

  • Class II Direct-Drive Blower: Higher static pressure, longer filter life, and greater reliability; spark resistant; no belts or pulleys to replace
  • Non-electrostatic Operation: High reliability, low maintenance
  • Ultra-Seal® Filter Mounting: Eliminates contaminant bypass of filters

Suitable For:

Top 5 contaminants/processes/applications:

  • Oil smoke
  • Coolant mist
  • Smoke
  • Dust
Don't see your contaminants? Give us a call! 1-888-862-5356 or Click our instant chatbox.

IMPORTANT: Make sure to talk to an application engineer before purchasing.
Part #
Qty 
Description
F91
1300 cfm source capture, industrial air cleaner with (1) 10' long, E-Z Arm ® overhead high flow extractor, (1) 2 aluminum mesh prefilter, (1) 95% bag filter, (96 sq.ft. of media), 3 HP TEFC motor, 208-230/460/575/5/60Hz (8/4 amps) and a high pressure, Cl

Frequently bought together these options:

Part #
Qty 
Description
F91-2P
2" Polyester Prefilter Option for Standard F91 Unit
F91-95DOP
95% DOP HEPA Filter Option for Standard F91 Unit, (24" x 20" x 12")
F91-AD
Adsorption option: includes (1) 4 pleated prefilter, (1) 95% short bag filter (36 sq.ft.), (2) refillable, v-bank absorber modules and (1) 2 pleated after-filter. 40 lbs. capacity; rated 1000 cfm. Order charcoal separately. (Adds 18 lbs. to ship weight)
F91-CV
CHEVRON ® option: includes (1) 2 mesh prefilter, (1) 4 CHEVRON ® mist eliminator, with standard 95% bag filter and (2) drains in cabinet (3/4 FPT).
F91-HEPA-12
99.97% HEPA (24x20x12)filter,
F91-HEPA-4
99.97% HEPA Filter Option for Standard F91 Unit
Part #
Qty 
Description
ARM PARTS
Order Arm Parts from E-Z ARM Page
F91-7E07
7 E-Z ARM 7' Long Option for Standard F91 Unit
  • Wall Bracket must be ordered separately
  • F91-7E14
    One (1) 14' long E-Z Arm ® high flow extractor in place of 10' long E-Z Arm ® high flow extractor.
  • Wall Bracket must be ordered separately
  • Part #
    Qty 
    Description
    F91-1-PHASE
    3HP 1 Phase BI Blower Option for Standard F91 Unit
    Part #
    Qty 
    Description
    F91-S-EXT
    Exhaust silencer Option for Standard F91 Unit
    Part #
    Qty 
    Description
    F91-PG-10
    0-10 magna-helic pressure gauge, approximately 5 diameter size. Surface mounted.
    LEV-MC-PG-5
    Pressure Gauge - complete with Wall, Ceiling or table mounting bracket and 0-5 pressure gauge. 3/16 inside diameter tubing ordered separately.
    PG-10
    Pressure Gauge - complete with Wall, Ceiling or table mounting bracket and 0-10 pressure gauge. 3/16 inside diameter tubing ordered separately.
    PG-6
    0-6 Magnahelic dial pressure gauge, surface mounted.
    Part #
    Qty 
    Description
    VFD-KIT-1HP-115-230-3
    1HP 120-240V Hybrid VFD 1 Phase In, 230V 3 Phase Output 60Hz complete with:
    • VFD NEMA 4
    • 1 HP Motor
    • Able to support HP lower than 1HP
    • Wiring
    • Labor
    • Re-certification
    • PLEASE NOTE: this kit is only required when upgrading a 120V system with a VFD
    VFD-KIT-2HP-115-230-3
    2HP 120-240V Hybrid VFD 1 Phase In, 230V 3 Phase Output 60Hz complete with:
    • VFD NEMA 4
    • 2 HP Motor
    • Able to support lower HP between 1HP - 2HP
    • Wiring
    • Labor
    • Re-certification
    • PLEASE NOTE: this kit is only required when upgrading a 120 or 220/1/60 V system with a VFD
    VFD-KIT-3HP-220-230-3
    3HP 240V Hybrid VFD 1 Phase In, 230V 3 Phase Output 60Hz complete with:
    • VFD NEMA 4
    • 3 HP Motor
    • Able to support lower HP between 2HP - 3HP
    • Wiring
    • Labor
    • Re-certification
    • PLEASE NOTE: this kit is only required when upgrading a 120V system with a VFD
    Get My Instant Quote