Specification Drawings
Solutions
Industries
Processes
Engineering Control Methods
Solutions
- Ducted Air Cleaners Learn More
Industries
Aerospace
Apparel & Clothing
Auto body repair
Chemicals and Plastics
Educational
Electronics
Farm & Heavy Equipment
Food & Beverage
Forensics
Machine Shop
Metalworking
Mining & Quarrying
Misc. Operations
MRO
Municipal & DOT Garage
Museums & Artifacts
National Defense
Robotics
Vehicle Repair
Waste Management
Welding Shops
Processes
- 3D Printing
- Buffing and Polishing
- Cigarette and Tobacco Smoke
- Clothing Assembly Line
- Deburring
- Farm Equipment Repair
- Food Packaging Plant
- Forensic Laboratories
- Heavy Equipment Repair
- Indoor Pistol and Small Bore Rifle Range Ventilation
- Lead Smelting
- Machine Shop
- Military Vehicle Repair
- Paleontology
- Pesticide Manufacturing
- Stainless Welding
- Steel Welding
- Surface Grinders
- Textile Dyeing
- Torch Cutting Ventilation
- Waste Management Facilities
- Welding Shop
Engineering Control Methods
No control methods exist for this product
F90 - 2800 CFM
F90 models collect dust, smoke, oil mist, oil smoke, and other atmospheric pollutants in industrial plants, shops, schools, and factories with high efficiency, 2 or 3 stage filtration. This model features a flow rate of 2800 CFM.
- Largest filtration, smallest dimensions
- Multiple installation configuration options, allowing for installation in congested areas
FUNCTION
CONSTRUCTION
KEY CRITERA
SUITABLE FOR
The F-90 Ducted Industrial Air Cleaner comes standard with (1) 4” (100mm) deep 30% pleated pre-filter, (1) 65% bag filter, 96ft² of media, and a 1.5 HP TEFC motor 208-230/460/575/3/60Hz. The fan is included inside the unit.
These units are complete, packaged air filter units that can easily be attached to ductwork and pickup hoses for at-the-source collection of pollutants.
There are multiple filter configurations available featuring washable and/or disposable filters. The unit can be upgraded with different filter and fan packages to suit various applications and contaminants.
Main Options:
These units are complete, packaged air filter units that can easily be attached to ductwork and pickup hoses for at-the-source collection of pollutants.
There are multiple filter configurations available featuring washable and/or disposable filters. The unit can be upgraded with different filter and fan packages to suit various applications and contaminants.
Main Options:
- Fan and Motor Upgrades
- Filter Options
- Pressure Gauges
- Variable Frequency Drives
CONSTRUCTION
- 16 Ga. steel cabinet with powder-coat finish
- Ultra-Seal® filter sealing system
- Side access door to filters
- Internal belt drive
- Ball bearing 10’ x 10’ blower with adjustable speed motor pulley
- 4-way adjustable airfoil blade exhaust grille
- Motor wired to external junction box; unit wired for 208V unless otherwise specified. (Motor starter not included.)
KEY CRITERA
- Capacities to 2800CFM: Handles toughest industrial applications
- Non-Electrostatic Operation: High reliability, low maintenance.
- Ultra-Seal® Filter Mounting: Eliminates contaminant bypass of filters.
- High-Efficiency Filter Media: Provides maximum effectiveness; low air-to-cloth ratio extends cycles between filter changes; filter changes easily without tools.
- Prewired to Junction Box: For fast, easy installation.
SUITABLE FOR
Top 5 contaminants/processes/applications:
IMPORTANT: For your Health and Safety, make sure to talk to an application engineer before purchasing.
- Oil Mist
- Wood Dust
- Oil Smoke
- Plastic Fumes
- Cannabis Dust
IMPORTANT: For your Health and Safety, make sure to talk to an application engineer before purchasing.
BASE MODELS, OPTIONS & ACCESSORIES
Part #
Description
F90
2800 CFM industrial air cleaner with:
- (1) 4” (100mm) deep 30" (760mm) pleated pre-filter
- (1) 65% bag filter (96ft²)
- 1.5 HP TEFC motor, 460/3/60Hz
Part #
Description
F90-0.95
95% bag filter (96 sq.ft) in place of standard 65% bag.
F90-2A
2" (50mm) aluminum mesh filter in place of 4" (100mm) pleated pre-filter.
F90-2P
2" (50mm) polyester filter with frame, 3.3 sq.ft., in place of 4" (100mm) pleated pre-filter.
F90-95DOP
Incl. 95% DOP proceeded by 95% bag filter (add 40 lbs. to shipping wt.). Rated 1600 CFM.
(24" x 20" x 4")
F90-AD
Adsorption option, includes:
- (1) 2" (50mm) aluminum mesh pre-filter
- (1) 95% short bag filter (36 sq.ft.)
- (2) refillable, v-bank absorber modules
- (1) 2" (50mm) pleated after-filter. 40 lbs. capacity; rated 1600 cfm
F90-CV
Chevron Filter Option for Standard F90 Unit, this option includes:
- (1) 2" (50mm) aluminum mesh pre-filter
- (1) 4" (100mm) CHEVRON ® mist eliminator
- (1) 95% bag filter (96 sq.ft.)
- (2) drains in cabinet (3/4" FPT)
F90-EC
Easy Clean Bag Filter Option for Standard F90 Unit (24" x 20" x 28").
F90-HEPA-12
99.97% DOP HEPA Filter Option for Standard F90 Unit - Larger Filter (24" x 20" x 12").
F90-HEPA-4
99.97% DOP HEPA Filter Option for Standard F90 Unit ( 4" x 20" x 4").
F90-R
Reduced maintenance pre-filter, includes plenum & 10 sq.ft. polyester pad (24" x 20" x 28").
Part #
Description
F90-PG-10
0-10" Magnahelic pressure gauge, approximately 5" (125mm)Ø size.
- Surface mounted
LEV-MC-PG-5
Pressure Gauge - complete with Wall, Ceiling, or Table Mounting Bracket, & 0-5" pressure gauge.
3/16 inside diameter tubing ordered separately.
LEV-PG-FM-01
Pressure Gauge 0-5" w.c. - Flush Mount - 01. Mounting kit/retrofit. Complete with pressure gauge, holding plates, tubing, and NPT fittings.
PG-10
Pressure Gauge - complete with Wall, Ceiling, or Table Mounting Bracket & 0-10" pressure gauge. 3/16 inside diameter tubing ordered separately.
PG-6
0-6" Magnahelic dial pressure gauge. Surface mounted
Part #
Description
2AU4-3004
Reduced maintenance pre-filter, includes plenum & 10Sq ft. polyester pad (Adds 20" to overall length and 35 lbs to ship weight).
2KT1-2701
AD or Hepa conversion Part for F120 or F90.
2KT9-3007
Outdoor Option - Rain Shield to protect upper door gasket.
HP-1.5-F90
1.5 HP TEFC Motor 115/230/1/60Jz (16/8 aamps) wired to external junction box, with on-off switch on 115v units.
FREQUENTLY BOUGHT TOGETHER
Part #
Description
F90-S-EXT
Exhaust Silencer Option for Standard F90 Unit.
Part #
Description
F90-DK
Drain Kit for F90 unit (2 kits needed with Chevron Option).
Part #
Description
F90-1- PHASE
115V Option for Standard F90 Unit1.5 HP TEFC motor, 115/230/1/60Hz (16/8 amps), wired to external junction box, with on-off switch on 115V units.
F90-3HP
3 HP TEFC motor, 208-230/460/575/3/60Hz, high pressure.3 HP TEFC motor, 208-230/460/575/3/60Hz, high pressure. Class II, spark resistant, direct drive, B.I. blower
F90-3HP-1PHASE
3 HP TEFC motor, 115/230/1/60Hz, high pressure, Class II, spark resistant, direct drive, B.I. blower.
Part #
Description
2AF1-8032
Easy Clean Bag Filter for F90 - Dusts, Mists & Gases - Multiple filter configurations available / Washable and/or Disposable filters - With Fan (500-2,000 CFM)
2AF2-8001
2" (50mm) Polyester filter with frame for F90 & F91 (24" x 20" x 2").
2AF2-8101
Louver oil mist separator for PAC-90, (20" x 24" x 2").
2AF4-8100
Chevron Filter impingement filter (24" x 20" x 4"). CV
2AF9-0002
AD Module, Absorber module,v-bank refillable. Holds 18 lbs. of charcoal, AD
2AZ2-0009
2" (50mm) Polyester Pre-filter (24" x 20" x 2").
2AZ2-0014
2" (50mm) Polyester Pre-filter, for R option only (26" x 51" x 2").
7FA8-0201
2" (50mm) Mesh Pre-filter (24" x 20" x 2").
7FB6-5201
65% Short Bag Filter (24" x 20" x 14").
7FB6-5232
65% Bag Filter (24" x 20" x 32").
7FB6-5232-OEM
65% Bag Filter for F90, F91 & PAC-90 (24" x 20" x 32").
7FB9-0201
95% Short Bag Filter for F-90 filter systems, (L14" x W24" x H20").
- QTY (8) bags
7FB9-0201-OEM
95% Short Bag Filter for F90, F91 and PAC-90, (24" x 20" x 14").
7FB9-0226
Bag filter for F90 & F91. Mini-pleat filter, (24" x 20" x 26"L).
7FB9-0232
95% Bag Filter for PAC-90 and F-90, (24" x 20" x 32")
7FH9-9212
99.97% DOP HEPA Filter, wood frame, (24" x 20" x 12").
7FH9-9212-OEM
HEPA, filter for F90, F91, & PAC-90, (24" x 20" x 12").
7FJ9-5204
DOP, Minipleat filter for F90 & F91, (24" x 20" x 4").
7FJ9-5212
DOP, 95% metal frame, (24" x 20" x 12").
7FJ9-9204
HEPA, Mini-pleat filter for F90 & P91, (24" x 20" x 4").
7FP1-4505-P
High Efficiency Filter for Pac-91, MP-30/60/120, F-120/122/240/360/480/, 202, 203, Mistpak Pro 2/3/4, Panel Filter Booth, Dustron Panel Booth, Easy Bench, & Air Pod (24" x 24" x 4").
7FP3-0104
4" (100mm) replacement pre-filter, 30% efficiency for the following units:
- EASY BENCH, T-140, F-120, F122, F240, F360, F480, 2400-DRY, 200, 202, 203, 2400VOM, T-3000, Pac-91, & others (24" x 24" x 4")
7FP3-0104-AAF
4" (100mm) replacement pre-filter, 30% efficiency for the following units:
- EASY BENCH, T-140, F-120, F122, F240, F360, F480, 2400-DRY, 200, 202, 203, 2400VOM, T-3000, Pac-91, & others (24" x 24" x 4")
7FP3-0202
Pleated filter for F90 & P91, (24" x 20" x 2").
7FP3-0204
4" (100mm) Pleated Pre-filter 30% Efficiency F90 - Dusts, Mists & Gases - Multiple filter configurations available.
- Washable and/or Disposable filters - With Fan (500-2,000 CFM), L4 W24 H20
7FP3-0204-OEM
4" (100mm) pleated filter for F90, F91, & PAC-90, (24" x 20" x 4").
CHARCOAL-20
20 lbs. of non-recycled coconut shell-based activated charcoal.
CHARCOAL-CP20
20 lbs. of CP Blend of chemisorbant and activated carbon blend.
Target Contaminants:
Target Contaminants:
- Hydrocarbons
- VOC's
- Oxides of sulfur
- Formaldehyde
- Nitric Oxide
- Hydrogen Sulfide
- Lower molecular weight
- Aldehydes & organic acids
CHARCOAL-CP40
40 lbs. of CP Blend of chemisorbant and activated carbon blend.
Target Contaminants:
Target Contaminants:
- Hydrocarbons
- VOC's
- Oxides of sulfur
- Formaldehyde
- Nitric Oxide
- Hydrogen Sulfide
- Lower molecular weight
- Aldehydes & organic acids
PP-24-6
Polyester replacement pad for Pre-filter (24" x 6").