model_icon

10-003

F240 - Ducted Air Cleaner

F240 models are designed to collect airborne dust, smoke, oil mist, oil smoke and other atmospheric pollutants in industrial plants, shops, schools and factories with high-efficiency multi-stage filtration . This model features a flow rate anywhere between 2000 - 4000 CFM .

Function:

The F240 ducted Industrial Air Cleaner comes standard with (2) 4” deep 30% pleated pre-filter, (2) 65% bag filter, 120ft² of media ea. and a 5 HP TEFC motor 208-230/460/575/3/60Hz. The fan is included inside the unit.

These units are complete, packaged air filter units that can easily be attached to ductwork and pickup hoses for at-the-source collection of pollutants.

There are multiple filter configurations available featuring washable and/or disposable filters. The unit can be upgraded with different filter and fan packages to suit various applications and contaminants.

Main Options:
  • Fan and Motor Upgrades
  • Filter Options
  • Pressure Gauges
  • Variable Frequency Drives
  • Sound Attenuation

Construction:

16 ga. steel cabinet with powder-coat finish; includes Ultra-Seal filter sealing system, side access door to filters, internal belt drive, ball bearing, 15 x 15 blower with adjustable speed motor pulley, 4-way adjustable airfoil blade, exhaust grille and motor wired to external junction box.

Shipping Dimensions and Weight:

Main System Part # Height x Width x Depth Weight
VOC2.0-7000-IN-ST 1"H x 1"W x 1"D 250 lbs
MSF240-VERTICAL-CV 34"H x 54"W x 106"D 250 lbs
MSF240-CV 39"H x 55.5"W x 78.25"D 952 lbs
F240-VERTICAL 40"H x 57"W x 128"D 700 lbs
F240 39"H x 55.5"W x 78.25"D 952 lbs

Suitable For:

Top 5 contaminants/processes/applications:

  • Oil Mist Wood Dust Oil Smoke Plastic Fumes Cannabis Dust - Dusts, Mists & Gases -
Don't see your contaminants? Give us a call! 1-888-862-5356 or Click our instant chatbox.

IMPORTANT: Make sure to talk to an application engineer before purchasing.
Part #
Qty 
Description
F240
6000 cfm industrial air cleaner with (2) 4 deep, 30% pleated prefilters, (2) 65% bag filters, 120 sq.ft. of media each, and a 5 HP TEFC motor. Please specify voltage when ordering.
F240-VERTICAL
6000 cfm industrial air cleaner with (2) 4 deep, 30% pleated prefilters, (2) 65% bag filters, 120 sq.ft. of media each, and a 5 HP TEFC motor. Please specify voltage when ordering. Vertical configuration includes:
  • Seam welded source capture plenum with 14D inlet
  • 24 Floor Stand
  • 14 D inlet to be on left hand side when looking at filter access door
  • MSF240-CV
    6000 cfm industrial air cleaner with (2) 4 deep, 30% pleated prefilters, (2) 65% bag filters, 120 sq.ft. of media each, and a 5 HP TEFC motor. Please specify voltage when ordering.
    MSF240-VERTICAL-CV
    6000 cfm industrial air cleaner with (2) 4 deep, 30% pleated prefilters, (2) 65% bag filters, 120 sq.ft. of media each, and a 5 HP TEFC motor. Please specify voltage when ordering. Vertical configuration includes:
  • Seam welded source capture plenum with 14D inlet
  • 24 Floor Stand
  • 14 D inlet to be on left hand side when looking at filter access door
  • VOC2.0-7000-IN-ST
    24" stand and inlet plenum. Welded source capture plenum with dual 14"D inlets
  • 24 Floor Stand
  • 14 D inlets
  • Frequently bought together these options:

    Part #
    Qty 
    Description
    VOLT-115-230
    To indicate the voltage for the specified unit.
  • 115/208-230/1/60
  • VOLT-230/3/60
    To indicate the voltage for the specified unit.
  • 230/3/60
  • VOLT-230-460/3/60
    To indicate the voltage for the specified unit.
  • 208-230-460/3/60
  • Motor starter and power cord not included
  • VOLT-575/3/60
    To indicate the voltage for the specified unit.
  • 575/3/60
  • Motor starter and power cord not included
  • Part #
    Qty 
    Description
    F240-0.95
    Two (2) 95% bag filters (120 sq.ft. each) in place of standard 65% bag filters.
    F240-2A
    Two (2) 2 aluminum mesh filters in place of 4 pleated prefilters.
    F240-2P
    Two (2) 2 polyester filters with frame, 4.0 sq.ft. each, in place of 4 pleated prefilters; metal frames with replaceable pads.
    F240-95DOP
    95%DOP HEPA Filter Option for Standard F240 Unit
    F240-AD
    Adsorption option; includes (2) 4 prefilters, (2) 95% short bag filters (64 sq.ft. each), (4) refillable, v-bank absorber modules, and (2) 2 pleated after-filters, 100 lbs. capacity; rated 4000 cfm. Order charcoal separately. (Adds 44 lbs. to ship weight)
    F240-AR
    Auto-roll prefilter option; includes automatic pressure switch advancement, 1/6 Hp motor, 1 or 3 phase . Includes initial 65' roll of 2 media.
    F240-CV
    CHEVRON ® option; includes (2) 2 aluminum mesh prefilters, (2) 4 CHEVRON® mist eliminators, (2) 95% bag filters (120 sq.ft. each) and (3) drains in cabinet (3/4 FPT).
    F240-EC
    Easy Clean Bag Filter Option for Standard F240 Unit
    FOF240-0.95-CV
    Two (2) 95% bag filters (120 sq.ft. each) in place of standard 65% bag filters.
    FOF240-2A-CV
    Two (2) 2 aluminum mesh filters in place of 4 pleated prefilters.
    FOF240-2P-CV
    Two (2) 2 polyester filters with frame, 4.0 sq.ft. each, in place of 4 pleated prefilters; metal frames with replaceable pads.
    FOF240-95DOP-CV
    95%DOP HEPA Filter Option for Standard F240 Unit
    FOF240-AD-CV
    Adsorption option; includes (2) 4 prefilters, (2) 95% short bag filters (64 sq.ft. each), (4) refillable, v-bank absorber modules, and (2) 2 pleated after-filters, 100 lbs. capacity; rated 4000 cfm. Order charcoal separately. (Adds 44 lbs. to ship weight)
    FOF240-AR-CV
    Auto-roll prefilter option; includes automatic pressure switch advancement, 1/6 Hp motor, 1 or 3 phase . Includes initial 65' roll of 2 media.
    FOF240-CV-CV
    CHEVRON ® option; includes (2) 2 aluminum mesh prefilters, (2) 4 CHEVRON® mist eliminators, (2) 95% bag filters (120 sq.ft. each) and (3) drains in cabinet (3/4 FPT).
    FOF240-EC-CV
    Easy Clean Bag Filter Option for Standard F240 Unit
    Part #
    Qty 
    Description
    DLPF-6-24
    Pre-filter 24" X 6" complete with mounting hardware. Replacement pads sold separately. Part No.: PP-24-6
    Part #
    Qty 
    Description
    F240-5HP-1PH
    5 HP OPEN motor, 230/1/60Hz (16 amps), with standard blower.
    F240-7-1/2 HP
    7-½ Hp TEFC motor, 208-230/460/575/3/60Hz, high pressure option.
    FMF240-5HP-1PH-CV
    5 HP OPEN motor, 230/1/60Hz (16 amps), with standard blower.
    FMF240-7-1/2 HP-CV
    7-½ Hp TEFC motor, 208-230/460/575/3/60Hz, high pressure option.
    Part #
    Qty 
    Description
    F240-S-EXT
    Silencer Option for Standard F240 Unit
    SAF240-S-EXT-CV
    Silencer Option for Standard F240 Unit
    Part #
    Qty 
    Description
    PG-6
    0-6 Magnahelic dial pressure gauge, surface mounted.
    F240-PG-10
    0-10" magna-helic pressure gauge, approximately 5" diameter size. Surface mounted.
    LEV-MC-PG-5
    Pressure Gauge - complete with Wall, Ceiling or table mounting bracket and 0-5 pressure gauge. 3/16 inside diameter tubing ordered separately.
    PG-10
    Pressure Gauge - complete with Wall, Ceiling or table mounting bracket and 0-10 pressure gauge. 3/16 inside diameter tubing ordered separately.
    PMF240-PG-10-CV
    0-10" magna-helic pressure gauge, approximately 5" diameter size. Surface mounted.
    Part #
    Qty 
    Description
    VFD-KIT-1HP-115-230-3
    1HP 120-240V Hybrid VFD 1 Phase In, 230V 3 Phase Output 60Hz complete with:
    • VFD NEMA 4
    • 1 HP Motor
    • Able to support HP lower than 1HP
    • Wiring
    • Labor
    • Re-certification
    • PLEASE NOTE: this kit is only required when upgrading a 120V system with a VFD
    VFD-KIT-2HP-115-230-3
    2HP 120-240V Hybrid VFD 1 Phase In, 230V 3 Phase Output 60Hz complete with:
    • VFD NEMA 4
    • 2 HP Motor
    • Able to support lower HP between 1HP - 2HP
    • Wiring
    • Labor
    • Re-certification
    • PLEASE NOTE: this kit is only required when upgrading a 120 or 220/1/60 V system with a VFD
    VFD-KIT-3HP-220-230-3
    3HP 240V Hybrid VFD 1 Phase In, 230V 3 Phase Output 60Hz complete with:
    • VFD NEMA 4
    • 3 HP Motor
    • Able to support lower HP between 2HP - 3HP
    • Wiring
    • Labor
    • Re-certification
    • PLEASE NOTE: this kit is only required when upgrading a 120V system with a VFD