95% DOP HEPA Filter Option for Standard 203 Unit.

Specificiations


Shipping Specificiations

Shipping Weight 1.0 lbs.
Shipping Length 1 in.
Shipping Width 1 in.
Shipping Height 1 in.
Model 10-008: 203 - 6000 CFM
The 203 Ducted Air cleaner is a blower-less unit designed to collect airborne dust, smoke, oil mist, oil smoke, and other atmospheric pollutants in industrial plants, shops, schools, and factories.

High-efficiency multi-stage filtration. This model features a flow rate anywhere from 3000 - 6000 CFM (multiple units can be combined for greater CFM).

  • Largest filtration, smallest dimensions
  • Multiple configurations allows for installation in congested areas

FUNCTION
Blower-less filtration housing designed with up to 4 stages of filtration for industrial applications. Filter system comes standard with (3) 4” (100mm) deep 30% pleated pre-filter, (3) 65% bag filter, 120ft² of media (per filter). The system can be upgraded with different filter and fan packages to suit a variety of applications and contaminants.

These units are complete, packaged air filter units that can easily be attached to ductwork and pickup hoses for at-the-source collection of pollutants.

There are multiple filter configurations available featuring washable and/or disposable filters. The unit can be upgraded with different filter and fan packages to suit various applications and contaminants.

Main Options:
  • Filter Options
  • Pressure Gauges
  • Variable Frequency Drives

CONSTRUCTION
  • 16 ga. welded zinc-coated steel cabinet
  • Two part chemical and oil resistant paint
  • ULTRA-SEAL filter mounting system
  • Hinged side access doors to filters
  • Blower less

KEY CRITERA
Application-Specific Design:
  • Contaminant-Specific Designs: Ability to tailor filter selection for specific contaminant, including air-cloth ratio
  • Variable Flowrate between 3000-6000CFM, giving the ability to set flowrate to suit your specific applications
  • Welded Construction: Eliminates the possibility of leaks between panels often found with bolted panel construction
  • Ideal as an after filter for dust collectors, where higher efficiency is needed
  • Environmental Resistance: Finished with a two part chemical and oil resistant paint, making it very resistant to harmful elements found in industrial facilities
  • Modular: Multiple units can be combined for higher flowrates to meet the spec required for any application
  • Ultra-Seal Filter Mount eliminates potential contaminant bypass of filters

SUITABLE FOR
Top 5 contaminants/processes/applications:

  • Oil Mist
  • Wood Dust
  • Oil Smoke
  • Plastic Fumes
  • Cannabis Dust

Solutions
Industries
  • Aerospace Aerospace
  • Apparel & Clothing Apparel & Clothing
  • Auto body repair Auto body repair
  • Chemicals and Plastics Chemicals and Plastics
  • Educational Educational
  • Electronics Electronics
  • Farm & Heavy Equipment Farm & Heavy Equipment
  • Food & Beverage Food & Beverage
  • Forensics Forensics
  • Machine Shop Machine Shop
  • Metalworking Metalworking
  • Mining & Quarrying Mining & Quarrying
  • Misc. Operations Misc. Operations
  • MRO MRO
  • Municipal & DOT Garage Municipal & DOT Garage
  • Museums & Artifacts Museums & Artifacts
  • National Defense National Defense
  • Robotics Robotics
  • Vehicle Repair Vehicle Repair
  • Waste Management Waste Management
  • Welding Shops Welding Shops
Processes
  • 3D Printing
  • Buffing and Polishing
  • Cigarette and Tobacco Smoke
  • Clothing Assembly Line
  • Deburring
  • Farm Equipment Repair
  • Food Packaging Plant
  • Forensic Laboratories
  • Heavy Equipment Repair
  • Indoor Pistol and Small Bore Rifle Range Ventilation
  • Lead Smelting
  • Machine Shop
  • Military Vehicle Repair
  • Paleontology
  • Pesticide Manufacturing
  • Stainless Welding
  • Steel Welding
  • Surface Grinders
  • Textile Dyeing
  • Torch Cutting Ventilation
  • Waste Management Facilities
  • Welding Shop
Engineering Control Methods
No control methods exist for this product

Contact sales for more information at sales@lev-co.com

IMPORTANT: For your Health and Safety, make sure to talk to an application engineer before purchasing.

All prices are FOB our warehouse in Port Perry, Ontario. Prices exclude taxes, delivery, installation, electrical work, mechanical installation, fire/explosion detection and suppression, mechanical and structural engineering, approvals, drawings, governmental permits, and related fees unless specifically noted above.


Payment terms are Net 30 OAC for quotes under $7,500. For quotes over $7,500, payment terms are 40/30/30 OAC: 40% with order, 30% prior to the day of shipment, and 30% Net 30. Orders must total a minimum of $500 NET. Interest of 18% per year will be charged on all overdue accounts. A 3% service charge will be applied to credit card payments.


Payment and Release of Goods

All products are subject to availability and will not be released for shipment or pickup until full payment has been received and processed. Products remain the property of Lev-co until payment has been received in full.


Clearance item pricing applies only to the specific product, quantity, and configuration shown on this quote. Clearance items are available on a first-come, first-served basis and are subject to prior sale. Products are not reserved until the order has been accepted by Lev-Co and any required deposit has been received. Clearance pricing and availability are valid only while quantities last and may change without notice as part of Lev-Co's Clearance Center pricing program.


Unless specifically noted otherwise, clearance items are new, unused Lev-Co products and include Lev-Co's standard 3-year limited warranty. All Lev-Co sales come with our limited 30-day satisfaction guarantee unless otherwise noted on the quote.


Due to the limited-quantity nature of clearance inventory, all cancellations, returns, or requests for RGA approval are reviewed on a case-by-case basis and require prior written approval from Lev-Co. Any approved return may be subject to a 30% restocking fee, plus applicable inspection, repackaging, repair, and freight charges. Requests for RGA approval must be submitted within 15 days of receipt. If you believe you may need to return a product, please request approval before purchasing.


The contents, documents, images, drawings, attachments, emails, videos, facsimiles, messages, and related materials contained in this quote and associated communications are confidential and remain the property of Lev-Co, The Local Exhaust & Ventilation Company Inc. They are intended solely for review by the intended recipient(s). Unauthorized use, copying, scanning, emailing, faxing, distribution, or other disclosure of this information is prohibited.


Payment is due in full upon shipment. Net terms may be offered at Lev-co's discretion to established clients who have maintained an account with Lev-co for two or more years.


Discontinued products

Lev-co does not assume liability for the improper installation, use, modification, maintenance, or operation of systems and components supplied by Lev-co. All components and systems must be installed by a licensed electrician, or the required licensed professional as required by local law. The end user is responsible for ensuring compliance with all applicable safety codes and authorities having jurisdiction.


Discontinued, obsolete, clearance, demo, surplus, used, or as-is products are sold on an "as-is, where-is" basis. Unless otherwise stated in writing by Lev-co, these products are sold without warranty, return, exchange, cancellation, or credit.


The purchaser is responsible for confirming the product is suitable for its intended use, including fit, function, compatibility, code compliance, installation requirements, and availability of replacement parts or consumables.


Lev-co shall not be liable for any direct, indirect, incidental, or consequential damages arising from the purchase, installation, use, lack of support, lack of replacement parts, or incompatibility of discontinued products.