(12-011) Meeting Room, Lunch Room, Coffee Room and Benches Ventilation System

Stand-alone VBF1 “2-Zone Air Defence” for Coffeerooms, Lunchrooms, Meeting rooms. and benches. A simple “Pre-engineered” solution with "Clean-to-less-clean" air distribution, HEPA H14 Filtration (99.995% @ 100 Nanometer), UVC (AKA: UVGI) light, Duct and Diffusion Hood.

The VBF ventilation systems have been designed to control, capture, filter and return contaminated air in various workplaces.

This solution employs the ventilation method of "Clean-to-less-clean" air movement coupled with HEPA filtration as recommended by the CDC, ASHRAE, WHO and more. By using this system you will immediately achieve 99.995% clean Air around the Table and after a short While a 98-99% Reduction of the Virus and Bacteria in the rest of the Room.

NEW GUIDANCE FROM CDC, ASHRAE, AND WHO, REGARDING 'CLEAN-TO-LESS-CLEAN AIR MOVEMENT':

Extracted from ASHRAE's Technical Resources for Healthcare Web Page
Airflow from Clean to Less Clean
  • More important than having to wait a longer time between room changeover due to lower ACH
  • More important than air change rate
  • More important than outside air % above 2ACH


By just having a normal conversation, aerosolized virus and bacteria can remain in the air indefinitely, therefore it is important to use forced air to direct these aerosols away from the occupants and allow them to be captured by the HEPA H14 fan/filter unit where the air can be filtered and returned to the space. This limits the transmission of respirable viruses such as Influenza, Coronavirus, common cold, etc. thus substantially reducing the risk of being infected. For example; the zone over and around a 6-person table is approximately 10m3. This gives you a total ACH (Air Changes Per HOUR of 60 VBF1-700 filters.

This solution has a typical payback of 1 year when compared to the costs of 1-week sick leave, per year, per employee.

The systems use a combination of clean-to-less-clean air movement, HEPA Filtration and optional UV light as recommended by both the CDC and ASHRAE. The cleaned air is supplied at a rate of 700 M3/H (400 CFM) or 1000 M3/H (600 CFM) per filter module, directly to the occupants breathing zone. This creates a "Bubble" of constantly filtered clean air around the table and up to 53 air changes in the room.*
Here's how it works:
  • STEP 1: The "Clean-to-less-clean" air movement supplies clean filtered air to the occupants breathing zone through a pre-engineered diffusion hood explicitly designed for the application (EG; meeting room, lunchroom, etc.). This precise air movement is essential as particles of this size can and most often will remain airborne, indefinitely.
  • STEP 2: The ultra-low noise fan draws the air in at floor level where the air is less clean and coolest. The fan is a variable speed centrifugally designed fan that allows you to control the flow
  • STEP 3: The air passes through a silenced chamber engineered to damper the associated noise generated from the movement of air.
  • STEP 4: The Multi-stage filter module filters the contaminated level of 99.995% @ 0.1 Micron (MicroMeters) or 100 NanoMeters NM. Viruses are typically in the Nano particle size. According to the LL University, 'Coronavirus particles are 120 nanometers' in size.
  • STEP 5: The Optional UV light can be purchased to be used as a supplement to help inactivate viruses (EG: SARS-CoV-2) attached to the inner surfaces of the inlet housing.
  • STEP 6: the filtered air is returned to the space through the low-noise smooth duct and on to the Diffuser hood detailed in step 1, thus completing the circuit. This allows the air in a typical room to be changed over 100 times an hour (ACH).

Product Function:


Stand-alone VBF1 “2-Zone Air Defence” for Coffeerooms, Lunchrooms, Meeting rooms. and benches. A simple “Pre-engineered” solution with "Clean-to-less-clean" air distribution, HEPA H14 Filtration (99.995% @ 100 Nanometer), UVC (AKA: UVGI) light, Duct and Diffusion Hood.

The VBF ventilation systems have been designed to control, capture, filter and return contaminated air in various workplaces.

This solution employs the ventilation method of "Clean-to-less-clean" air movement coupled with HEPA filtration as recommended by the CDC, ASHRAE, WHO and more. By using this system you will immediately achieve 99.995% clean Air around the Table and after a short While a 98-99% Reduction of the Virus and Bacteria in the rest of the Room.

NEW GUIDANCE FROM CDC, ASHRAE, AND WHO, REGARDING 'CLEAN-TO-LESS-CLEAN AIR MOVEMENT':

Extracted from ASHRAE's Technical Resources for Healthcare Web Page
Airflow from Clean to Less Clean
  • More important than having to wait a longer time between room changeover due to lower ACH
  • More important than air change rate
  • More important than outside air % above 2ACH


By just having a normal conversation, aerosolized virus and bacteria can remain in the air indefinitely, therefore it is important to use forced air to direct these aerosols away from the occupants and allow them to be captured by the HEPA H14 fan/filter unit where the air can be filtered and returned to the space. This limits the transmission of respirable viruses such as Influenza, Coronavirus, common cold, etc. thus substantially reducing the risk of being infected. For example; the zone over and around a 6-person table is approximately 10m3. This gives you a total ACH (Air Changes Per HOUR of 60 VBF1-700 filters.

This solution has a typical payback of 1 year when compared to the costs of 1-week sick leave, per year, per employee.

The systems use a combination of clean-to-less-clean air movement, HEPA Filtration and optional UV light as recommended by both the CDC and ASHRAE. The cleaned air is supplied at a rate of 700 M3/H (400 CFM) or 1000 M3/H (600 CFM) per filter module, directly to the occupants breathing zone. This creates a "Bubble" of constantly filtered clean air around the table and up to 53 air changes in the room.*
Here's how it works:
  • STEP 1: The "Clean-to-less-clean" air movement supplies clean filtered air to the occupants breathing zone through a pre-engineered diffusion hood explicitly designed for the application (EG; meeting room, lunchroom, etc.). This precise air movement is essential as particles of this size can and most often will remain airborne, indefinitely.
  • STEP 2: The ultra-low noise fan draws the air in at floor level where the air is less clean and coolest. The fan is a variable speed centrifugally designed fan that allows you to control the flow
  • STEP 3: The air passes through a silenced chamber engineered to damper the associated noise generated from the movement of air.
  • STEP 4: The Multi-stage filter module filters the contaminated level of 99.995% @ 0.1 Micron (MicroMeters) or 100 NanoMeters NM. Viruses are typically in the Nano particle size. According to the LL University, 'Coronavirus particles are 120 nanometers' in size.
  • STEP 5: The Optional UV light can be purchased to be used as a supplement to help inactivate viruses (EG: SARS-CoV-2) attached to the inner surfaces of the inlet housing.
  • STEP 6: the filtered air is returned to the space through the low-noise smooth duct and on to the Diffuser hood detailed in step 1, thus completing the circuit. This allows the air in a typical room to be changed over 100 times an hour (ACH).

Construction:


Each system Fan/Filter module complete with 4-stage filtration:

1. Prefilter for larger particles >50 microns. (Washable)
2. High-efficiency F5 class secondary filter 40-60% efficiency on particles larger than 0.4 microns. (Disposable)
3. High-Efficiency HEPA H14 class final filter 99.995% efficient on particles smaller than 0.1 microns. (Delivered with Efficiency and leak test Certificate)
4. Outlet filter of washable Aluminum mesh (Washable)

Additional Information:

- Optional bacteria-killing UVC lamps can be equipped. The UVC lamps are placed before the HEPA H14 filter to kill surface viruses, mould and bacteria.
- All VBF Air-purifiers come complete with 120V variable-speed EC motors. Units are delivered ready to plug in and use. The fan speed can be adjusted to suit precise "Draft free" airspeeds and "Ultra Quiet" noise levels.
- The VBF Hoods are available in 4 lengths: 1m (2-4 people), 1.5m (4-6 people), 2m (6-8 people), and 2.5m (8-10 people).
- The Duct kit is complete with lightweight sheet metal ducting, duct fitting, Chains (to hang the hood and duct), and Hooks (for the ceiling).
- The duct kit and hood are simple to install and typically require no more than 30 minutes to set up.
- Designed in our typical heavy-duty "all steel" construction and using the highest quality materials.
- All units are delivered complete with 4x5" diameter locking casters. Alternatively, 5" legs can be ordered separately.

Frequently bought together these options:

Part #
Qty 
Description
L-830
COVID-CBF1/700/2-Zone 700 m3/h (400 CFM) FILTER UNIT. HEPA H14(8M2). Vertical Duct D.200/1.1m. EC 1-phase, 120V, 60Hz,175W.
L-831
COVID-CBF1/1000/2-Zone 1000 m3/h (600 CFM) FILTER UNIT. HEPA H14(13M2). Vertical Duct D200/0.8m. EC 1-phase, 120V, 60Hz, 175W.
Part #
Qty 
Description
L-818
Diffusion Hood 1m (2 Persons). Inlet D.200, White Hose 0.5m/D.200, Suspension Chains 4x2m and 4+4 Hooks. White.
L-819
Diffusion Hood 1.5m (4 Persons). Inlet D.200, White Hose 0,5m/D.200, Suspension Chains 4x2m and 4+4 Hooks. White.
L-820
Diffusion Hood 2m (6 persons). Inlet D.200, White Hose 0,5m/D.200, Suspension Chains 4x2m and 4+4 Hooks. White.
L-829
Diffusion Hood 2.5m (8 persons). Inlet D.200, White Hose 0,5m/D.200, Suspension Chains 4x2m and 4+4 Hooks. White.
Part #
Qty 
Description
L-824
Horizontal Duct work L=2m. 2 Bends 90/D.200, Duct D.200 (0.8m+0.8m), Suspension Chains 4x2m and 2+2 Hooks. White.
L-825
Horizontal Duct work L=2.3 m. 2 Bends 90/D.200, Duct D.200(1.1m+0.8m), Suspension Chains 4x2m and 2+2 Hooks. White.
L-826
Horizontal Duct work L=2.6m. 2 Bends 90/D.200, Duct D.200 (1.1m+1.1m), Suspension Chains 4x2m and 2+2 Hooks. White.
L-827
Horizontal Duct work L=2.8m. 2 Bends 90/200, Duct D.200 (0.8m+0.8m+0.8m), Suspension Chains 6x2m and 6+6 Hooks. White.
Part #
Qty 
Description
L-836
Horizontal Extension Duct L=0.6m/D.200, Male Coupling D.200, Suspension Chains 2x2m and 2+2 Hooks. White.
L-837
Horizontal Extension Duct L=0.8m/D.200, Male Coupling D.200, Suspension Chains 2x2m and 2+2 Hooks. White.
L-838
Horizontal Extension Duct L=1.1m/D.200, Male Coupling D.200, Suspension Chains 2x2m, 2+2 Hooks. White.
Part #
Qty 
Description
L-802
Replacement HEPA filter coronavirus H14 (8M2) for COVID-CBF-700 Models. Certificate and Leak Test.
L-803
Replacement HEPA filter coronavirus H14 (13m2) for COVID-CBF-1000 Models. Certificate and Leak Test.
Technical Info Requested
To make sure that you are a human being and not a robot, please also enter the letters you see below: