model_icon
(12-06) MS200-CV - Non-Powered Filtration & Powered Return from Floor Level - No Fan (1,000-2,000 CFM)
Blower-less filtration housing designed with up to 4 stages of filtration for industrial applications. Designed to handle airflow between 1000 & 2000 CFM , (multiple units can be combined for greater CFM). Filter system comes standard with (1) 4” deep 30% pleated pre-filter, (1) 65% bag filter, 120ft² of media. System can be upgraded with different filter and fan packages to suit a variety of applications and contaminants.

Product Function:

Blower-less filtration housing designed with up to 4 stages of filtration for industrial applications. Designed to handle airflow between 1000 & 2000 CFM , (multiple units can be combined for greater CFM). Filter system comes standard with (1) 4” deep 30% pleated pre-filter, (1) 65% bag filter, 120ft² of media. System can be upgraded with different filter and fan packages to suit a variety of applications and contaminants.

Construction:

16 ga. welded zinc coated steel cabinet, finished with a two part chemical and oil resistant paint, with ULTRA-SEAL filter mounting system and hinged side access doors to filters. Blower less.

Shipping Dimensions and Weight:

Main System Part # Length x Width x Height Weight
BI-270-85-3 53"H x 53"W x 60"D 700 lbs
BI-165-75-3 1"H x 1"W x 1"D 150 lbs
BI-165-75-2 30"H x 30"W x 30"D 150 lbs
BI-135-75-3 30"H x 30"W x 31"D 300 lbs
BI-135-75-2 30"H x 30"W x 31"D 300 lbs
BI-135-100 30"H x 30"W x 31"D 300 lbs
Part #
Qty 
Description
MS200-CV
Modular air cleaner, blower less. Includes 4” pleated 30% prefilter, 95% main filter, 120 sq. ft.
BI-122-70-2
Industrial Exhaust Fan 1300 CFM @ 9 w.g. to 2000 CFM@5 w.g. BI Direct Drive Fan c/w slip fit inlet, Slip Fit outlet; Class II c/w, 3 HP, 230-460V/3/60, 3600 RPM. AMCA Type B construction.
BI-122-70-3
Industrial Exhaust Fan 1300 CFM @ 9 w.g. to 2000 CFM@5 w.g. BI Direct Drive Fan c/w slip fit inlet, Slip Fit outlet; Class II c/w, 3 HP, 575V/3/60, 3600 RPM. AMCA Type B construction.
BI-135-100
Industrial Exhaust Fan 1800 CFM@1.5 w.g. BI Direct Drive Fan c/w slip fit inlet, Slip Fit outlet; Class II c/w, 1.5 HP, 115/230/1/60, 1750 RPM. AMCA type B
BI-135-75-2
Industrial Exhaust Fan 2000 CFM@10 w.g. to 3000 CFM@5 w.g. BI Direct Drive Fan c/w slip fit inlet, Slip Fit outlet; Class II c/w, 5 HP, 230-460V/3/60, 3600 RPM. AMCA type B
BI-135-75-3
Industrial Exhaust Fan 2000 CFM@10 w.g. to 3000 CFM@5 w.g. BI Direct Drive Fan c/w slip fit inlet, Slip Fit outlet; Class II c/w, 5 HP, 575V/3/60, 3600 RPM. AMCA type B
BI-150-90-2
Industrial Exhaust Fan 3000 CFM@9 w.g. to 4500 CFM@5 w.g. BI Direct Drive Fan c/w slip fit inlet, Slip Fit outlet; Class II c/w 7.5 HP, 230-460V/3/60, 3600 RPM. AMCA type B construction
BI-150-90-3
Industrial Exhaust Fan 3000 CFM@9 w.g. to 4500 CFM@5 w.g. BI Direct Drive Fan c/w slip fit inlet, Slip Fit outlet; Class II c/w 7.5 HP, 575V/3/60, 3600 RPM. AMCA type B construction
BI-165-75-2
Industrial Exhaust Fan 4000 CFM@10 w.g. to 5000 CFM@6 w.g. BI Direct Drive Fan c/w slip fit inlet, Slip Fit outlet; Class IV c/w 10 HP/3 PH, 230-460V/3/60, 3600 RPM. AMCA Type B Construction
BI-165-75-3
Industrial Exhaust Fan 4000 CFM@10 w.g. to 5000 CFM@6 w.g. BI Direct Drive Fan c/w slip fit inlet, Slip Fit outlet; Class IV c/w 10 HP/3 PH, 575V/3/60, 3600 RPM. AMCA Type B Construction
BI-182-70-2
Industrial Exhaust Fan 5000 CFM@12" w.g. to 7000 CFM@4 w.g. BI Direct Drive Fan c/w slip fit inlet, Slip Fit outlet; Class IV c/w 15 HP/3 HP, 230-460V/3/60, 3600 RPM. AMCA type B construction
BI-182-70-3
Industrial Exhaust Fan 5000 CFM@12" w.g. to 7000 CFM@4 w.g. BI Direct Drive Fan c/w slip fit inlet, Slip Fit outlet; Class IV c/w 15 HP/3 HP, 575V/3/60, 3600 RPM. AMCA type B construction
BI-182-95-2
Industrial Exhaust Fan 5000 CFM@12" w.g. to 7000 CFM@4 w.g. BI Direct Drive Fan c/w slip fit inlet, Slip Fit outlet; Class IV c/w 15 HP/3 HP, 230-460V/3/60, 3600 RPM. AMCA type B construction
BI-182-95-3
Industrial Exhaust Fan 5000 CFM@12" w.g. to 7000 CFM@4 w.g. BI Direct Drive Fan c/w slip fit inlet, Slip Fit outlet; Class IV c/w 15 HP/3 HP, 575V/3/60, 3600 RPM. AMCA type B construction
BI-270-65-2
10,000 CFM@7.5" w.g. to 12,000 CFM@5.5 w.g. BI Direct Drive Fan c/w slip fit inlet, flanged outlet; Class IV c/w 20 HP/3 HP, 230-460V/3/60, 1750 RPM.
BI-270-65-3
10,000 CFM@7.5" w.g. to 12,000 CFM@5.5 w.g. BI Direct Drive Fan c/w slip fit inlet, flanged outlet; Class IV c/w 20 HP/3 HP, 575V/3/60, 1750 RPM.
BI-270-85-2
Industrial Exhaust Fan 12,000 CFM@8" w.g. to 14,500 CFM@5.5 w.g. BI Direct Drive Fan c/w slip fit inlet, Slip Fit outlet; Class IV c/w 25 HP/3 HP, 230/460/3/60, 1750 RPM.AMCA type B construction
BI-270-85-3
Industrial Exhaust Fan 12,000 CFM@8" w.g. to 14,500 CFM@5.5 w.g. BI Direct Drive Fan c/w slip fit inlet, Slip Fit outlet; Class IV c/w 25 HP/ 3 HP, 575V/3/60, 1750 RPM. AMCA type B construction
BI-270-100-2
Industrial Exhaust fan 14,000 CFM@8 w.g. to 17,000 CFM@5.5 w.g. BI Direct Drive Fan c/w slip fit inlet, Slip Fit outlet; Class IV c/w 30 HP 230/460/3/60, 1750 RPM.AMCA type B construction
BI-270-100-3
Industrial Exhaust Fan 14,000 CFM@8 w.g. to 17,000 CFM@5.5 w.g. BI Direct Drive Fan c/w slip fit inlet, Slip Fit outlet; Class IV c/w 30 HP 575V/3/60, 1750 RPM.AMCA type B construction
BI-300-100-2
Industrial Exhaust fan 14,000 CFM@8 w.g. to 17,000 CFM@5.5 w.g. BI Direct Drive Fan c/w slip fit inlet, Slip Fit outlet; Class IV c/w 30 HP 230/460/3/60, 1750 RPM.AMCA type B construction
BI-300-100-3
Industrial Exhaust fan 14,000 CFM@8 w.g. to 17,000 CFM@5.5 w.g. BI Direct Drive Fan c/w slip fit inlet, Slip Fit outlet; Class IV c/w 30 HP 575V/3/60, 1750 RPM.AMCA type B construction

Frequently bought together these options:

Part #
Qty 
Description
FO200-0.65-CV
65% Bag Filter Option for Standard 200 Unit
FO200-2A-CV
2 aluminum mesh filter in place of 4 pleated prefilter.
FO200-95DOP-CV
95% DOP HEPA Filter Option for Standard 200 Unit
FO200-AD-CV
Adsorption option; includes (1) 4 prefilter, (1) 95% short bag filter (64 sq.ft.), (2) refillable, v-bank absorber modules and (1) 2 pleated after-filter, 50 lbs. capacity, rate 2000 cfm. Order charcoal separately. (Adds 22 lbs. to ship weight).
FO200-CV-CV
CHEVRON® option; includes (1) 2 aluminum mesh prefilter, (1) 4 CHEVRON ® mist eliminator, (1) 95% bag filter (120 sq.ft.) and (2) drains in cabinet (3/4 FPT).
FO200-EC-CV
(1) Easy clean, polyester membrane, cleanable bag filter, MERV 12; replaces standard 95% throw-away filter.
FO200-HEPA-CV
99.97% DOP HEPA Filter Option for Standard 200 Unit
Part #
Qty 
Description
LEV-MC-PG-5
Pressure Gauge - complete with Wall, Ceiling or table mounting bracket and 0-5 pressure gauge. 3/16 inside diameter tubing ordered separately.
PG-10
Pressure Gauge - complete with Wall, Ceiling or table mounting bracket and 0-10 pressure gauge. 3/16 inside diameter tubing ordered separately.
PG-3
0-3"liquid gauge, surface mounted pressure gauge for T140
Part #
Qty 
Description
2AZ2-0005
2 inch Polyester Prefilter for F-70C/AirPod I/II/III (Pad only 4.5 sq feet)
Part #
Qty 
Description
DLPF-6-24
Pre-filter 24" X 6" complete with mounting hardware. Replacement pads sold separately. Part No.: PP-24-6
Part #
Qty 
Description
PF-2PTM
Prefilter – 2” polyester tackified media.
Part #
Qty 
Description
BI-122-AFS
Adjustable front support, to be used in conjunction with the optional exhaust stack.
BI-135-AFS
Adjustable front support, to be used in conjunction with the optional exhaust stack.
BI-150-AFS
Adjustable front support, to be used in conjunction with the optional exhaust stack.
BI-165-AFS
Adjustable front support, to be used in conjunction with the optional exhaust stack.
BI-182-AFS
Adjustable front support, to be used in conjunction with the optional exhaust stack.
BI-122-AR-INLET
Optional standard angle ring hole pattern adapter.
BI-135-AR-INLET
Optional standard angle ring hole pattern adapter.
BI-150-AR-INLET
Optional standard angle ring hole pattern adapter.
BI-165-AR-INLET
Optional standard angle ring hole pattern adapter.
BI-182-AR-INLET
Optional standard angle ring hole pattern adapter.
Part #
Qty 
Description
FAN-0.75-RAD3600-8
Fan, 600 CFM (free-blowing) air and maximum static pressure of 2.75” of Static Pressure W.G.. Motor is direct mounted for Low maintenance and ease of installation.
FAN-1.5-RAD3600-9
Fan, 1200 CFM (free-blowing) air and maximum static pressure of 3.20” of Static Pressure W.G.. Motor is direct mounted for Low maintenance and ease of installation.
FAN-3.0-RAD3600-11
Fan, 1800 CFM (free-blowing) air and maximum static pressure of 5.00” of Static Pressure W.G.. Motor is direct mounted for Low maintenance and ease of installation.
Part #
Qty 
Description
VFD-KIT-1HP-115-230-3
1HP 120-240V Hybrid VFD 1 Phase In, 230V 3 Phase Output 60Hz complete with:

  • VFD NEMA 4
  • 1 HP Motor
  • Wiring
  • Labor
  • Re-certification

  • PLEASE NOTE: this kit is only required when upgrading a 120V system with a VFD
  • VFD-KIT-2HP-115-230-3
    2HP 120-240V Hybrid VFD 1 Phase In, 230V 3 Phase Output 60Hz complete with:

  • VFD NEMA 4
  • 2 HP Motor
  • Wiring
  • Labor
  • Re-certification

  • PLEASE NOTE: this kit is only required when upgrading a 120 or 220/1/60 V system with a VFD
  • VFD-KIT-3HP-220-230-3
    3HP 240V Hybrid VFD 1 Phase In, 230V 3 Phase Output 60Hz complete with:

  • VFD NEMA 4
  • 3 HP Motor
  • Wiring
  • Labor
  • Re-certification

  • PLEASE NOTE: this kit is only required when upgrading a 120V system with a VFD
  • Part #
    Qty 
    Description
    BI-122-C
    AMCA type C spark resistant construction option for the BI-122 series fans.
    BI-135-C
    AMCA type C spark resistant construction option for the BI-135 series fans.
    BI-150-C
    AMCA type C spark resistant construction option for the BI-150 series fans.
    BI-165-C
    AMCA type C spark resistant construction option for the BI-165 series fans.
    BI-182-C
    AMCA type C spark resistant construction option for the BI-182 series fans.
    Part #
    Qty 
    Description
    SIL-BI-122-R0
    Silencer option for BI-122-70 Fan.
    SIL-BI-135-R0
    Silencer option for BI-135-75 Fan
    SIL-BI-150-R0
    Silencer option for BI-150-90 Fan
    SIL-BI-165-R0
    Silencer option for BI-165-75 Fan
    SIL-BI-182-R0-1
    Silencer option for BI-182-70 Fan
    Part #
    Qty 
    Description
    BI-DRAIN
    Drain, optional accessory for BI Fans, 1/2" Push in connection. Installed on site, step drill bit included with kit. To be installed at the lowest point on the fan.
    BI-ACC-DOOR
    Quick open access/inspection door for BI fans
    BI-EPOXY-122
    Epoxy paint option for BI-122 fans. Including all accessories.
    BI-EPOXY-135
    Epoxy paint option for BI-135 fans. Including all accessories.
    BI-EPOXY-150
    Epoxy paint option for BI-150 fans. Including all accessories.
    BI-EPOXY-165
    Epoxy paint option for BI-165 fans. Including all accessories.
    BI-EPOXY-182
    Epoxy paint option for BI-182 fan. Including all accessories.
    Part #
    Qty 
    Description
    PG-20
    0-20 Mini-Helic pressure gauge, approximately 3" diameter size. Surface mounted.
    Part #
    Qty 
    Description
    LEV-ESTACK-BI-122
    No loss stack with gravity damper for the BI-122-70 fan.
    LEV-ESTACK-BI-135
    No loss stack with gravity damper for the BI-135-70 fan.
    LEV-ESTACK-BI-150
    No loss stack with gravity damper for the BI-150-90 fan.
    LEV-ESTACK-BI-165
    No loss stack with gravity damper for the BI-165-X fan.
    LEV-ESTACK-BI-182
    No loss stack with gravity damper for the BI-182-70 fan.
    Part #
    Qty 
    Description
    P-766-HD-GALV-1
    Heavy duty galvanized main fan mounting bracket ONLY.
    Technical Info Requested