Home
Company
Catalogue
Industries
Processes
Control Methods
Products
Login
Contact Us
Forgot Password?
Login to site
(10-06) 200 - Dusts, Mists & Gases - Multiple filter configurations available / Washable and/or Disposable filters - No Fan (1,000-2,000 CFM**)
Blower-less filtration housing designed with up to 4 stages of filtration for industrial applications. Designed to handle airflow between 1000 & 2000 CFM , (multiple units can be combined for greater CFM). Filter system comes standard with (1) 4” deep 30% pleated pre-filter, (1) 65% bag filter, 120ft² of media. System can be upgraded with different filter and fan packages to suit a variety of applications and contaminants.
Product Function
Construction
Shipping Weight
and Dimensions
Product Function:
Blower-less filtration housing designed with up to 4 stages of filtration for industrial applications. Designed to handle airflow between 1000 & 2000 CFM , (multiple units can be combined for greater CFM). Filter system comes standard with (1) 4” deep 30% pleated pre-filter, (1) 65% bag filter, 120ft² of media. System can be upgraded with different filter and fan packages to suit a variety of applications and contaminants.
Construction:
16 ga. welded zinc coated steel cabinet, finished with a two part chemical and oil resistant paint, with ULTRA-SEAL filter mounting system and hinged side access doors to filters. Blower less.
Shipping Dimensions and Weight:
Main System Part #
Length x Width x Height
Weight
200
35.5"H x 32"W x 43"D
175 lbs
Main System / Part
Part #
Qty
Description
200
0
1
2
3
4
5
6
7
8
9
10
Modular air cleaner, blower less. Includes 4” pleated 30% prefilter, 95% main filter, 120 sq. ft.
Frequently bought together these options:
Filter Options (when ordering with main unit)
Part #
Qty
Description
200-0.65
0
1
2
3
4
5
6
7
8
9
10
65% Bag Filter Option for Standard 200 Unit
200-2A
0
1
2
3
4
5
6
7
8
9
10
2 aluminum mesh filter in place of 4 pleated prefilter.
200-95DOP
0
1
2
3
4
5
6
7
8
9
10
95% DOP HEPA Filter Option for Standard 200 Unit
200-AD
0
1
2
3
4
5
6
7
8
9
10
Adsorption option; includes (1) 4 prefilter, (1) 95% short bag filter (64 sq.ft.), (2) refillable, v-bank absorber modules and (1) 2 pleated after-filter, 50 lbs. capacity, rate 2000 cfm. Order charcoal separately. (Adds 22 lbs. to ship weight).
200-CV
0
1
2
3
4
5
6
7
8
9
10
CHEVRON® option; includes (1) 2 aluminum mesh prefilter, (1) 4 CHEVRON ® mist eliminator, (1) 95% bag filter (120 sq.ft.) and (2) drains in cabinet (3/4 FPT).
200-EC
0
1
2
3
4
5
6
7
8
9
10
(1) Easy clean, polyester membrane, cleanable bag filter, 80% efficiency; replaces standard 95% throw-away filter.
200-HEPA
0
1
2
3
4
5
6
7
8
9
10
99.97% DOP HEPA Filter Option for Standard 200 Unit
FO200-0.65-CV
0
1
2
3
4
5
6
7
8
9
10
65% Bag Filter Option for Standard 200 Unit
FO200-2A-CV
0
1
2
3
4
5
6
7
8
9
10
2 aluminum mesh filter in place of 4 pleated prefilter.
FO200-95DOP-CV
0
1
2
3
4
5
6
7
8
9
10
95% DOP HEPA Filter Option for Standard 200 Unit
FO200-AD-CV
0
1
2
3
4
5
6
7
8
9
10
Adsorption option; includes (1) 4 prefilter, (1) 95% short bag filter (64 sq.ft.), (2) refillable, v-bank absorber modules and (1) 2 pleated after-filter, 50 lbs. capacity, rate 2000 cfm. Order charcoal separately. (Adds 22 lbs. to ship weight).
FO200-CV-CV
0
1
2
3
4
5
6
7
8
9
10
CHEVRON® option; includes (1) 2 aluminum mesh prefilter, (1) 4 CHEVRON ® mist eliminator, (1) 95% bag filter (120 sq.ft.) and (2) drains in cabinet (3/4 FPT).
FO200-EC-CV
0
1
2
3
4
5
6
7
8
9
10
(1) Easy clean, polyester membrane, cleanable bag filter, MERV 12; replaces standard 95% throw-away filter.
FO200-HEPA-CV
0
1
2
3
4
5
6
7
8
9
10
99.97% DOP HEPA Filter Option for Standard 200 Unit
BI (Backward Inclined) Centrally Ducted Fans (Motor Starter not included)
Part #
Qty
Description
FAN-0.75-RAD3600-8
0
1
2
3
4
5
6
7
8
9
10
Fan, 600 CFM (free-blowing) air and maximum static pressure of 2.75” of Static Pressure W.G.. Motor is direct mounted for Low maintenance and ease of installation.
FAN-1.5-RAD3600-9
0
1
2
3
4
5
6
7
8
9
10
Fan, 1200 CFM (free-blowing) air and maximum static pressure of 3.20” of Static Pressure W.G.. Motor is direct mounted for Low maintenance and ease of installation.
FAN-3.0-RAD3600-11
0
1
2
3
4
5
6
7
8
9
10
Fan, 1800 CFM (free-blowing) air and maximum static pressure of 5.00” of Static Pressure W.G.. Motor is direct mounted for Low maintenance and ease of installation.
2''- Pre-Filters
Part #
Qty
Description
2AZ2-0005
0
1
2
3
4
5
6
7
8
9
10
2 inch Polyester Prefilter for F-70C/AirPod I/II/III (Pad only 4.5 sq feet)
Filter Media Options
Part #
Qty
Description
DLPF-6-24
0
1
2
3
4
5
6
7
8
9
10
Pre-filter 24" X 6" complete with mounting hardware. Replacement pads sold separately. Part No.: PP-24-6
Variable Frequency Drives
Part #
Qty
Description
VFD-KIT-1HP-115-230-3
0
1
2
3
4
5
6
7
8
9
10
1HP 120-240V Hybrid VFD 1 Phase In, 230V 3 Phase Output 60Hz complete with:
VFD NEMA 4
1 HP Motor
Wiring
Labor
Re-certification
PLEASE NOTE: this kit is only required when upgrading a 120V system with a VFD
VFD-KIT-2HP-115-230-3
0
1
2
3
4
5
6
7
8
9
10
2HP 120-240V Hybrid VFD 1 Phase In, 230V 3 Phase Output 60Hz complete with:
VFD NEMA 4
2 HP Motor
Wiring
Labor
Re-certification
PLEASE NOTE: this kit is only required when upgrading a 120 or 220/1/60 V system with a VFD
VFD-KIT-3HP-220-230-3
0
1
2
3
4
5
6
7
8
9
10
3HP 240V Hybrid VFD 1 Phase In, 230V 3 Phase Output 60Hz complete with:
VFD NEMA 4
3 HP Motor
Wiring
Labor
Re-certification
PLEASE NOTE: this kit is only required when upgrading a 120V system with a VFD
Accessories
Part #
Qty
Description
PG-20
0
1
2
3
4
5
6
7
8
9
10
0-20 Mini-Helic pressure gauge, approximately 3" diameter size. Surface mounted.
Preventative Maintenance Pressure Gauges, etc. (when ordering main unit)
Part #
Qty
Description
LEV-MC-PG-5
0
1
2
3
4
5
6
7
8
9
10
Pressure Gauge - complete with Wall, Ceiling or table mounting bracket and 0-5 pressure gauge. 3/16 inside diameter tubing ordered separately.
PG-10
0
1
2
3
4
5
6
7
8
9
10
Pressure Gauge - complete with Wall, Ceiling or table mounting bracket and 0-10 pressure gauge. 3/16 inside diameter tubing ordered separately.
PG-3
0
1
2
3
4
5
6
7
8
9
10
0-3"liquid gauge, surface mounted pressure gauge for T140
GET MY
INSTANT QUOTE
Name
Company
Email
Phone
Project
Comments
Technical Info Requested
Spec Drawing
Brochure
Case Study
Video
To make sure that you are a human being and not a robot, please also enter the letters you see below:
Enter letters above