model_icon
(11-025) MPH-5 (500 CFM) **
500 cfm source capture mist collector with (3) MIST-PLUS ™ II main filter with (1) MERV14 pleated synthetic, washable filter. (17.5" x 18.5" x 3.75"). ½ HP 115/1/60 Hz (7.2/3.6 amps) 71 dB, with rubber vibration isolator, or 208-230/460/3/60 Hz (2.6-2/1 amps), with a 8" COLLAR ON BOTTOM.

Product Function:

500 cfm source capture mist collector with (3) MIST-PLUS ™ II main filter with (1) MERV14 pleated synthetic, washable filter. (17.5" x 18.5" x 3.75"). ½ HP 115/1/60 Hz (7.2/3.6 amps) 71 dB, with rubber vibration isolator, or 208-230/460/3/60 Hz (2.6-2/1 amps), with a 8" COLLAR ON BOTTOM.

Construction:

16 ga. Welded steel cabinet with powder-coat finish. Includes a top filter access door, Ultra-Seal ® filter mounting system. An acoustically lined blower cabinet with access panel. Painted Gray with a 8" inlet collar on the bottom. 1 phase units with 6' power cord and lighted rocker switch. 3 phase units wired to a junction box; circuit and motor overload protection by others.

Shipping Dimensions and Weight:

Main System Part # Length x Width x Height Weight
MPH5 34"H x 30"W x 56"D 237 lbs
Part #
Qty 
Description
MPH5
500 cfm source capture mist collector with (3) MIST-PLUS II main filter. ½ Hp 115/1/60 Hz (7.2/3.6 amps) 71 dBA, with rubber vibration isolator.
  • Grey Colour
  • Inlet underneath the unit
  • 115V motor AS PER CANADIAN LAW; this unit is electrically approved by CSA/ESA field evaluation.
  • Frequently bought together these options:

    Part #
    Qty 
    Description
    2AF8-4550
    MIST-PLUS ™II filter, metal frames. for MPH5
    7FJ9-9004
    HEPA, 99.97% filter for MP-14, PR01, MPH5, MPH10.
    7FP1-4502
    Filter pleated. Synthetic, Washable. MERV 15 efficiency.
    Part #
    Qty 
    Description
    VFD-KIT-1HP-115-230-3
    1HP 120-240V Hybrid VFD 1 Phase In, 230V 3 Phase Output 60Hz complete with:

  • VFD NEMA 4
  • 1 HP Motor
  • Wiring
  • Labor
  • Re-certification

  • PLEASE NOTE: this kit is only required when upgrading a 120V system with a VFD
  • VFD-KIT-2HP-115-230-3
    2HP 120-240V Hybrid VFD 1 Phase In, 230V 3 Phase Output 60Hz complete with:

  • VFD NEMA 4
  • 2 HP Motor
  • Wiring
  • Labor
  • Re-certification

  • PLEASE NOTE: this kit is only required when upgrading a 120 or 220/1/60 V system with a VFD
  • VFD-KIT-3HP-220-230-3
    3HP 240V Hybrid VFD 1 Phase In, 230V 3 Phase Output 60Hz complete with:

  • VFD NEMA 4
  • 3 HP Motor
  • Wiring
  • Labor
  • Re-certification

  • PLEASE NOTE: this kit is only required when upgrading a 120V system with a VFD
  • Part #
    Qty 
    Description
    LEV-MC-PG-5
    Pressure Gauge - complete with Wall, Ceiling or table mounting bracket and 0-5 pressure gauge. 3/16 inside diameter tubing ordered separately.
    PG-10
    Pressure Gauge - complete with Wall, Ceiling or table mounting bracket and 0-10 pressure gauge. 3/16 inside diameter tubing ordered separately.
    Technical Info Requested