(03-03) DCH-2 - Heavy Duty Dusts & Smoke - Self cleaning filter system built in - 600 to 1,200 CFM - 8” Ø inlet **
Cartridge dust collector with (2) Clean 2® cartridge filter (150ft² of media each), manual VIBRA-PULSE® filter cleaning system, and 8" collar on top. Includes a 10 gallon external dust drawer or tray.
Product Function
Construction
Shipping Weight
and Dimensions
Product Function:
Cartridge dust collector with (2) Clean 2® cartridge filter (150ft² of media each), manual VIBRA-PULSE® filter cleaning system, and 8" collar on top. Includes a 10 gallon external dust drawer or tray.
Construction:
12/14/16 ga. welded steel cabinet with powder-coat finish; includes removable end cap for easy access to filters, removable back panel for access to direct drive motor/blower compartment. The unit comes with the motor wired to a junction box outside of the unit (Motor starter not included unless specified as option)
Shipping Dimensions and Weight:
Main System Part #
Length x Width x Height
Weight
DCH-2-H10
66"H x 35"W x 65"D
458 lbs
DCH-2-55Gallon
48"H x 36"W x 55"D
445 lbs
DCH-2
36"H x 29"W x 49"D
370 lbs
Main System / Part
Part #
Qty
Description
DCH-2-REG
0
1
2
3
4
5
6
7
8
9
10
Regulator Option for Standard DCH-2 Unit
DCH-2
0
1
2
3
4
5
6
7
8
9
10
Cartridge collector w/2 Clean 2® cartridge filters (150 ft2 media each) manual Vibra-Pulse®. 1.5HP 115/230/1/60, 17/8.5 amps, w/switch cord on 115 volt only, & spark resistant blower. 8”collar on top & removable external dust tray.
DCH-2-H10
0
1
2
3
4
5
6
7
8
9
10
Cartridge collector w/10 gallon Hopper (w/ stand & dust can) 2 Clean 2® cartridge filters (150 ft2 media each) manual Vibra-Pulse®. 1.5HP 115/230/1/60v, 17/8.5 amps w/switch cord (115v only) & spark res. blower. 8”collar on top & ext. dust tray.
DCH-2-55Gallon
0
1
2
3
4
5
6
7
8
9
10
Cartridge collector w/2 Clean 2® cartridge filters (150 ft2 media each) manual Vibra-Pulse®. 1.5HP 115/230/1/60, 17/8.5 amps, w/switch cord on 115 volt only, & spark resistant blower. 8"collar on top & removable external dust tray. WITH 55 Gallon Hopper
Frequently bought together these options:
Fan / Motor Upgrades or Options (when ordering main unit)
Part #
Qty
Description
DCH-2-5HP
0
1
2
3
4
5
6
7
8
9
10
5 Hp TEFC motor, 208-230-460-575/3/60Hz, High Flow Option for Standard DCH-2 Unit
DCH-2-3 PHASE
0
1
2
3
4
5
6
7
8
9
10
1.5 Hp, TEFC motor 208-230-460/575/3/60 Hz, Standard Blower Option for Standard DCH-2 Unit
DCH-2-3HP-1PHASE
0
1
2
3
4
5
6
7
8
9
10
3 Hp TEFC motor,230/1/60 Hz, High Flow Option for Standard DCH-2 Unit
DCH-2-1PHASE-D
0
1
2
3
4
5
6
7
8
9
10
1.5 Hp, 1 phase, Class 1, Div. 2, Group D motor/blower for the DCH-2
DCH-2-3HP-3PH
0
1
2
3
4
5
6
7
8
9
10
3 Hp TEFC motor, 208-230-460-575/3/60 Hz, High Flow Option for Standard DCH-2 Unit
Filter Options (when ordering with main unit)
Part #
Qty
Description
DCH-2-EXAD
0
1
2
3
4
5
6
7
8
9
10
External Adsorber Module Option for Standard DCH-2 Unit
DCH-2-EXDOP
0
1
2
3
4
5
6
7
8
9
10
External 95% DOP Filter Option for Standard DCH-2 Unit. True "HEPA"
DCH-2-EXHE - SS
0
1
2
3
4
5
6
7
8
9
10
External 99.97% HEPA Filter Option for Standard DCH-2 Unit
DCH-2-FD
0
1
2
3
4
5
6
7
8
9
10
Fiber dust Filters Option for Standard DCH-2 Unit
DCH-2-UCP
0
1
2
3
4
5
6
7
8
9
10
ULTRACLEAN-PLUS Cartridge Filters Option for Standard DCH-2 Unit
DCH-2-AD
0
1
2
3
4
5
6
7
8
9
10
Internal AD Option for Standard DCH-2 Unit
Variable Frequency Drives
Part #
Qty
Description
VFD-AC-220V-1P/3P-3HP-NEMA4X
0
1
2
3
4
5
6
7
8
9
10
3HP 240V Hybrid VFD 220V/1 Phase In, 230V/3 Phase Out 60Hz
VFD-AC-460V-3HP-NEMA4X-WHT
0
1
2
3
4
5
6
7
8
9
10
3.0 HP AC DRIVE ,460V single or 3 PH IN 3 PH OUT in NEMA 4 enclosure and simple "Dial/Potentiometer" speed control.
VFD-KIT-3HP-220-230-3
0
1
2
3
4
5
6
7
8
9
10
3HP 240V Hybrid VFD 1 Phase In, 230V 3 Phase Output 60Hz complete with:
VFD NEMA 4
3 HP Motor
Wiring
Labor
Re-certification
PLEASE NOTE: this kit is only required when upgrading a 120V system with a VFD
VFD-KIT-1HP-115-230-3
0
1
2
3
4
5
6
7
8
9
10
1HP 120-240V Hybrid VFD 1 Phase In, 230V 3 Phase Output 60Hz complete with:
VFD NEMA 4
1 HP Motor
Wiring
Labor
Re-certification
PLEASE NOTE: this kit is only required when upgrading a 120V system with a VFD
VFD-KIT-2HP-115-230-3
0
1
2
3
4
5
6
7
8
9
10
2HP 120-240V Hybrid VFD 1 Phase In, 230V 3 Phase Output 60Hz complete with:
VFD NEMA 4
2 HP Motor
Wiring
Labor
Re-certification
PLEASE NOTE: this kit is only required when upgrading a 120 or 220/1/60 V system with a VFD
Silencer Option (when ordering main unit)
Part #
Qty
Description
DCH-2-S-EXT
0
1
2
3
4
5
6
7
8
9
10
External Silencer Option for Standard DCH-2 Unit
Fan, Light & Other Electrical Accessories
Part #
Qty
Description
DCH-2-AP-1
0
1
2
3
4
5
6
7
8
9
10
Off line Auto Pulse, 1 Phase Option for Standard DCH-2 Unit
DCH-2-AP-3
0
1
2
3
4
5
6
7
8
9
10
Off line Auto Pulse, 3 Phase Option for Standard DCH-2 Unit
Accessories
Part #
Qty
Description
2KT5-2740
0
1
2
3
4
5
6
7
8
9
10
Hopper Retrofit ( for an existing DCH-2)
Preventative Maintenance Pressure Gauges, etc. (when ordering main unit)
Part #
Qty
Description
2PG5-PCH2
0
1
2
3
4
5
6
7
8
9
10
0-5" Minihelic dial pressure gauge, flush mounted. Not recommended with EXHE, EXAD OR EXDOP OPTIONS.
DCH-2-PG-10
0
1
2
3
4
5
6
7
8
9
10
0-10 magna-helic pressure gauge, approximately 5 diameter size. Remote mounted.
DCH-2-PG-10-RENTAL
0
1
2
3
4
5
6
7
8
9
10
Rental 0-10 magna-helic pressure gauge, approximately 5 diameter size. Remote mounted.
GET MY
INSTANT QUOTE
Name
Company
Email
Phone
Project
Comments
Technical Info Requested
Spec Drawing
Brochure
Case Study
Video
To make sure that you are a human being and not a robot, please also enter the letters you see below:
Enter letters above