model_icon
(07-05) HC-4-Flexi **
Horizontal cartridge collector w/4 Clean-2® filter cartridges. Comes prepared to accept up to 4 Flexi© Extractor Arms (ordered separately), which allows for excellent extraction right at source. This solution is ideal when a packaged "Pre-engineered" solution is required. Suitable for most welding and light dust applications.

Product Function:

Horizontal cartridge collector w/4 Clean-2® filter cartridges. Comes prepared to accept up to 4 Flexi© Extractor Arms (ordered separately), which allows for excellent extraction right at source. This solution is ideal when a packaged "Pre-engineered" solution is required. Suitable for most welding and light dust applications.

Construction:

14 & 16 ga. steel cabinet with powder-coat finish; includes front access panel to AMCA Type B, non-sparking, blower/motor, (2) removable end caps for easy access to filters, (2) hoppers with 7.88” diameter outlets, 4-way, adjustable airfoil blade, exhaust grille and motor wired to junction box outside unit. (Motor starter not included.)

Shipping Dimensions and Weight:

Main System Part # Length x Width x Height Weight
P-146 15"H x 12"W x 65"D 56 lbs
P-145 12"H x 15"W x 54"D 52 lbs
P-144 15"H x 12"W x 54"D 50 lbs
P-143 14"H x 12"W x 37.5"D 41 lbs
P-008 12"H x 10"W x 53"D 42 lbs
P-007 12"H x 10"W x 34"D 36 lbs
Part #
Qty 
Description
HC-4-DUCTED-1
Horizontal cartridge collector w/(4) Clean 2 filter cartridges, Auto-Clean Off-Line Vibra-Pulse filter cleaning system and a 3 HP TEFC Motor 230/460/3/60 Hz. Unit comes c/w 2 duct connections.

Frequently bought together these options:

Part #
Qty 
Description
VFD-KIT-1HP-115-230-3
1HP 120-240V Hybrid VFD 1 Phase In, 230V 3 Phase Output 60Hz complete with:

  • VFD NEMA 4
  • 1 HP Motor
  • Wiring
  • Labor
  • Re-certification

  • PLEASE NOTE: this kit is only required when upgrading a 120V system with a VFD
  • VFD-KIT-2HP-115-230-3
    2HP 120-240V Hybrid VFD 1 Phase In, 230V 3 Phase Output 60Hz complete with:

  • VFD NEMA 4
  • 2 HP Motor
  • Wiring
  • Labor
  • Re-certification

  • PLEASE NOTE: this kit is only required when upgrading a 120 or 220/1/60 V system with a VFD
  • VFD-KIT-3HP-220-230-3
    3HP 240V Hybrid VFD 1 Phase In, 230V 3 Phase Output 60Hz complete with:

  • VFD NEMA 4
  • 3 HP Motor
  • Wiring
  • Labor
  • Re-certification

  • PLEASE NOTE: this kit is only required when upgrading a 120V system with a VFD
  • Part #
    Qty 
    Description
    P-025-120S-120V-1PH-2.0 HP
    Energy Saver E- Man© 115V/1/60. Fan Motor control station. Rated up to 2 HP. Permits start-stop of the fan / Dustcollector from a Remote Switch/control. Remote mounted switches must be ordered separately but it is best to interlock the fan with the associate process. Comes complete with relevant Motor overload. Please specify Motor HP when ordering ______.Also includes a 50 VA 120V AC transformer for powering the dust collectors sequencer.
    P-025-120S-208/230V-3PH-7.5 HP
    Energy Saver E- Man© 208-230V/3/60. Fan Motor control station. Rated up to 7.5 HP. Permits start-stop of the fan / Dustcollector from a Remote Switch/control. Remote mounted switches must be ordered separately but it is best to interlock the fan with the associate process. Comes complete with relevant Motor overload. Please specify Motor HP when ordering ______.Also includes a 50 VA 120V AC transformer for powering the dust collectors sequencer.
    P-025-120S-240V-1PH-3HP
    Energy Saver E- Man© 240V/1/60. Fan Motor control station. Rated up to 3 HP. Permits start-stop of the fan / Dustcollector from a Remote Switch/control. Remote mounted switches must be ordered separately but it is best to interlock the fan with the associate process. Comes complete with relevant Motor overload. Please specify Motor HP when ordering ______.Also includes a 50 VA 120V AC transformer for powering the dust collectors sequencer.
    P-025-120S-460V-3PH-20HP
    Energy Saver E- Man© 460V/3/60. Fan Motor control station. Rated up to 20 HP. HP. Permits start-stop of the fan / Dustcollector from a Remote Switch/control. Remote mounted switches must be ordered separately but it is best to interlock the fan with the associate process. Comes complete with relevant Motor overload. Please specify Motor HP when ordering ______.Also includes a 50 VA 120V AC transformer for powering the dust collectors sequencer.
    Starter-MNT
    Kit for mounting Magnetic or Manual starters for T-140
    Part #
    Qty 
    Description
    HC-4-S-EXT
    Exhaust Silencer Option for Standard HC-4 Unit
    Part #
    Qty 
    Description
    P-025-120S-575V-3PH-20HP
    Energy Saver E- Man© 575V/3/60. Fan Motor control station. Rated up to 20 HP. HP. Permits start-stop of the fan / Dustcollector from a Remote Switch/control. Remote mounted switches must be ordered separately but it is best to interlock the fan with the associate process. Comes complete with relevant Motor overload. Please specify Motor HP when ordering ______.Also includes a 50 VA 120V AC transformer for powering the dust collectors sequencer.
    Part #
    Qty 
    Description
    LEV-MC-PG-5
    Pressure Gauge - complete with Wall, Ceiling or table mounting bracket and 0-5 pressure gauge. 3/16 inside diameter tubing ordered separately.
    PG-10
    Pressure Gauge - complete with Wall, Ceiling or table mounting bracket and 0-10 pressure gauge. 3/16 inside diameter tubing ordered separately.
    REG
    Regulator Kit Option for Standard Vibra-Pulse cleaning systems
    Technical Info Requested