model_icon
(03-01) DCH-1 - Heavy Duty Dusts & Smoke - Self cleaning filter system built in - 300 to 800 CFM - 6” Ø inlet **
Cartridge collector with (1) Clean 2® cartridge filter (150ft² of media each), manual VIBRA-PULSE® filter cleaning system, and 6" collar on top. Includes either a 5 gallon external dust drawer or 10 gallon pail and hopper.

Product Function:

Cartridge collector with (1) Clean 2® cartridge filter (150ft² of media each), manual VIBRA-PULSE® filter cleaning system, and 6" collar on top. Includes either a 5 gallon external dust drawer or 10 gallon pail and hopper.

Construction:

12/14/16 ga. welded steel cabinet with powder-coat finish; includes removable end cap for easy access to filters, removable back panel for access to direct drive motor/blower compartment. For 115/1/60 the unit comes with 25’ of 12 ga. power cord and on-off switch. For 3 phase option (230/460/575) the unit comes with the motor wired to a junction box outside of the unit (Motor starter not included.)

Shipping Dimensions and Weight:

Main System Part # Length x Width x Height Weight
DCH-1-H10 66"H x 35"W x 43"D 350 lbs
DCH-1 41"H x 35"W x 43"D 300 lbs
Part #
Qty 
Description
DCH-1
Cartridge collector with 1 Clean 2® cartridge filter with 150 ft2 media, manual Vibra-Pulse® cleaning system 1HP 115/230/1/60 TEFC motor at 12/6 amps, 6” collar on top. Includes removable external dust tray.
  • AS PER CANADIAN LAW; this unit is electrically approved by CSA/ESA field evaluation.
  • DCH-1-H10
    Cartridge collector with (1) CLEAN-2 cartridge filter (150 sq. ft. of media), manual VIBRA-PULSE filter cleaning system, a 1 HP TEFC motor, 115/230/1/60Hz (12/6 amps), 6" dia. inlet collar on top, hopper with stand, and 10 gallon dust container.
  • AS PER CANADIAN LAW; this unit is electrically approved by CSA/ESA field evaluation.
  • Frequently bought together these options:

    Part #
    Qty 
    Description
    DCH-1-3 PHASE
    1.5 Hp, TEFC motor 575/3/60 Option for Standard DCH-1 Unit
    DCH-1-HP-1.5-1
    1.5 Hp TEFC motor, 115/208-.230/1/60Hz, (15/7.9-7.5 amps) high pressure, spark resistant, backward incline blower. 900 cfm. 74 dBA...
    DCH-1-HP-3
    1.5 Hp TEFC motor,208-230/460/575/3/60 Hz, High Pressure Option for Standard DCH-1 Unit
    Part #
    Qty 
    Description
    DCH-1-AD
    Internal AD Option for Standard DCH-1 Unit. Order Charcoal separately.
    DCH-1-EXAD
    External Adsorber Module Option for Standard DCH-1 Unit. Order Charcoal separately.
    DCH-1-EXDOP
    External 95% DOP Filter Option for Standard DCH-1 Unit
    DCH-1-EXHE
    External 99.97% HEPA Filter Option for Standard DCH-1 Unit
    DCH-1-FD
    Fiber dust Filters Option for Standard DCH-1 Unit
    DCH-1-UCP
    ULTRACLEAN-PLUS Cartridge Filters Option for Standard DCH-1 Unit
    Part #
    Qty 
    Description
    VFD-AC-220V-1P/3P-3HP-NEMA4X
    3HP 240V Hybrid VFD 220V/1 Phase In, 230V/3 Phase Out 60Hz
    VFD-AC-230V-3P/3P-2HP-NEMA4X-WHT
    2.0 HP AC DRIVE ,230V single or 3 PH IN 3 PH OUT in NEMA 4 enclosure and simple "Dial/Potentiometer" speed control.
    VFD-AC-230V-3P/3P-3HP-NEMA4X-WHT
    3.0 HP AC DRIVE ,230V single or 3 PH IN 3 PH OUT in NEMA 4 enclosure and simple "Dial/Potentiometer" speed control.
    VFD-AC-460V-3HP-NEMA4X-WHT
    3.0 HP AC DRIVE ,460V single or 3 PH IN 3 PH OUT in NEMA 4 enclosure and simple "Dial/Potentiometer" speed control.
    VFD-KIT-1HP-115-230-3
    1HP 120-240V Hybrid VFD 1 Phase In, 230V 3 Phase Output 60Hz complete with:

  • VFD NEMA 4
  • 1 HP Motor
  • Wiring
  • Labor
  • Re-certification

  • PLEASE NOTE: this kit is only required when upgrading a 120V system with a VFD
  • VFD-KIT-2HP-115-230-3
    2HP 120-240V Hybrid VFD 1 Phase In, 230V 3 Phase Output 60Hz complete with:

  • VFD NEMA 4
  • 2 HP Motor
  • Wiring
  • Labor
  • Re-certification

  • PLEASE NOTE: this kit is only required when upgrading a 120 or 220/1/60 V system with a VFD
  • VFD-KIT-3HP-220-230-3
    3HP 240V Hybrid VFD 1 Phase In, 230V 3 Phase Output 60Hz complete with:

  • VFD NEMA 4
  • 3 HP Motor
  • Wiring
  • Labor
  • Re-certification

  • PLEASE NOTE: this kit is only required when upgrading a 120V system with a VFD
  • Part #
    Qty 
    Description
    DCH-1-S-EXT
    External Silencer Option for Standard DCH-1 Unit
    Part #
    Qty 
    Description
    DCH-1-AP-1
    Off line Auto Pulse, 1 Phase Option for Standard DCH-1 Unit
    DCH-1-AP-3
    Off line Auto Pulse, 3 Phase Option for Standard DCH-1 Unit
    Part #
    Qty 
    Description
    DCH-1-PG-10
    0-10" magna-helic pressure gauge, approximately 5" diameter size. Surface mounted.
    Technical Info Requested
    To make sure that you are a human being and not a robot, please also enter the letters you see below: