model_icon
(06-05) PB Back Draft Modules - Dust - Self cleaning filter system built in - 4’ X 4’ BD Hood (5,000 CFM/module)**
A free standing Dust Control Booth with 6 Clean 2® cartridge filters, dual dust drawers, slotted inlet hood, 5 HP 208-230/460/575/3/60hz motor with non-sparking AMCA Type B wheel, Vibra-Pulse® cleaning.

Product Function:

A free standing Dust Control Booth with 6 Clean 2® cartridge filters, dual dust drawers, slotted inlet hood, 5 HP 208-230/460/575/3/60hz motor with non-sparking AMCA Type B wheel, Vibra-Pulse® cleaning.

Construction:

Shipping Dimensions and Weight:

Main System Part # Length x Width x Height Weight
PB-1 67"H x 131"W x 34"D 1040 lbs
Part #
Qty 
Description
PB-1
4500 CFM free standing cartridge dust collector with 6 Clean 2® cartridge filters, dual dust drawers, slotted inlet hood, 5 HP 208-230/460/3/60hz motor with non-sparking AMCA Type B wheel, Auto - Clean Vibra-Pulse® filter cleaning system. AS PER CANADIAN LAW; this unit is electrically approved by CSA/ESA field evaluation.
PB-2
4500 CFM free standing cartridge dust collector with 6 Clean 2® cartridge filters, dual dust drawers, slotted inlet hood, 5 HP 575/3/60hz motor with non-sparking AMCA Type B wheel, Auto - Clean Vibra-Pulse® filter cleaning system. AS PER CANADIAN LAW; this unit is electrically approved by CSA/ESA field evaluation.

Frequently bought together these options:

Part #
Qty 
Description
PB-EXAD
External adsorption option: includes (4) refillable, v-bank adsorber modules, 100 lbs. capacity, and (2) 2 pleated after-filters; rated 4000 CFM. Order charcoal separately. (Adds 15 to height.)
PB-EXHE
External HEPA Option for Standard POWERBOOTH Unit
PB-SPUNPOLY
Six (6) Spunbond Polyester Cartridge Filters Option for Standard POWERBOOTH Unit
PB-WELDING
Welding/Ferrous Grinding Option for Standard POWERBOOTH Unit. Replaces standard inlet grill with non-reflective grid
Part #
Qty 
Description
VFD-KIT-1HP-115-230-3
1HP 120-240V Hybrid VFD 1 Phase In, 230V 3 Phase Output 60Hz complete with:

  • VFD NEMA 4
  • 1 HP Motor
  • Wiring
  • Labor
  • Re-certification

  • PLEASE NOTE: this kit is only required when upgrading a 120V system with a VFD
  • VFD-KIT-2HP-115-230-3
    2HP 120-240V Hybrid VFD 1 Phase In, 230V 3 Phase Output 60Hz complete with:

  • VFD NEMA 4
  • 2 HP Motor
  • Wiring
  • Labor
  • Re-certification

  • PLEASE NOTE: this kit is only required when upgrading a 120 or 220/1/60 V system with a VFD
  • VFD-KIT-3HP-220-230-3
    3HP 240V Hybrid VFD 1 Phase In, 230V 3 Phase Output 60Hz complete with:

  • VFD NEMA 4
  • 3 HP Motor
  • Wiring
  • Labor
  • Re-certification

  • PLEASE NOTE: this kit is only required when upgrading a 120V system with a VFD
  • Part #
    Qty 
    Description
    P-025-120S-120V-1PH-2.0 HP
    Energy Saver E- Man© 115V/1/60. Fan Motor control station. Rated up to 2 HP. Permits start-stop of the fan / Dustcollector from a Remote Switch/control. Remote mounted switches must be ordered separately but it is best to interlock the fan with the associate process. Comes complete with relevant Motor overload. Please specify Motor HP when ordering ______.Also includes a 50 VA 120V AC transformer for powering the dust collectors sequencer.
    P-025-120S-208/230V-3PH-7.5 HP
    Energy Saver E- Man© 208-230V/3/60. Fan Motor control station. Rated up to 7.5 HP. Permits start-stop of the fan / Dustcollector from a Remote Switch/control. Remote mounted switches must be ordered separately but it is best to interlock the fan with the associate process. Comes complete with relevant Motor overload. Please specify Motor HP when ordering ______.Also includes a 50 VA 120V AC transformer for powering the dust collectors sequencer.
    P-025-120S-240V-1PH-3HP
    Energy Saver E- Man© 240V/1/60. Fan Motor control station. Rated up to 3 HP. Permits start-stop of the fan / Dustcollector from a Remote Switch/control. Remote mounted switches must be ordered separately but it is best to interlock the fan with the associate process. Comes complete with relevant Motor overload. Please specify Motor HP when ordering ______.Also includes a 50 VA 120V AC transformer for powering the dust collectors sequencer.
    Starter-MNT
    Kit for mounting Magnetic or Manual starters for T-140
    Part #
    Qty 
    Description
    P-025-120S-575V-3PH-20HP
    Energy Saver E- Man© 575V/3/60. Fan Motor control station. Rated up to 20 HP. HP. Permits start-stop of the fan / Dustcollector from a Remote Switch/control. Remote mounted switches must be ordered separately but it is best to interlock the fan with the associate process. Comes complete with relevant Motor overload. Please specify Motor HP when ordering ______.Also includes a 50 VA 120V AC transformer for powering the dust collectors sequencer.
    Part #
    Qty 
    Description
    LEV-MC-PG-5
    Pressure Gauge - complete with Wall, Ceiling or table mounting bracket and 0-5 pressure gauge. 3/16 inside diameter tubing ordered separately.
    PG-10
    Pressure Gauge - complete with Wall, Ceiling or table mounting bracket and 0-10 pressure gauge. 3/16 inside diameter tubing ordered separately.
    Technical Info Requested
    To make sure that you are a human being and not a robot, please also enter the letters you see below: