(11-15) 1200 VOM (1200 CFM) **
1200 CFM source capture industrial air cleaner. It features a 2" impingement pre-filter, a 2" aluminum mesh filter, a 95% main filter (25 sq. ft of media), a one HP TEFC motor, and a 8" dia. inlet in front only.
Product Function
Construction
Shipping Weight
and Dimensions
Product Function:
1200 CFM source capture industrial air cleaner. It features a 2" impingement pre-filter, a 2" aluminum mesh filter, a 95% main filter (25 sq. ft of media), a one HP TEFC motor, and a 8" dia. inlet in front only.
Construction:
16 ga. welded steel cabinet with powder-coat finish. Includes Ultra-Seal™ filter mounting system, side access door to filters and motor/blower compartment, wall mount/rod hanging brackets for installation, a 3” deep welded oil sump with 1.5” FPT drain, direct drive blower, on-off switch and 6’ power cord for 115V units; 230/1 phase and 3 phase units are wired to a side junction box. Motor starter not included.
UNIT: 16”W x 44”H x 24”D
SHIP: 19”W x 51”H x 30”D
Shipping Dimensions and Weight:
Main System Part #
Length x Width x Height
Weight
1200 VOM
30"H x 19"W x 51"D
270 lbs
1200 - DRY
51"H x 19"W x 30"D
270 lbs
Main System / Part
Part #
Qty
Description
1200 - DRY
0
1
2
3
4
5
6
7
8
9
10
1200 cfm dry source capture industrial air cleaner with (1) 2 polyester prefilter, (1) 2 aluminum mesh prefilter, (1) 95% main filter (25 sq.ft. of media), 1 HP TEFC motor, 115/230/1/60Hz and a 8 INLET ON FRONT ONLY. (NO SIDE OR BACK INLET). 72 dBA.
1200 VOM
0
1
2
3
4
5
6
7
8
9
10
1200 CFM source capture industrial air cleaner with 2 impingement prefilter, 2 aluminum mesh filter, 12 deep main cartridge filter, 95%, and one 8 inlet in front and 1.5 drain.
Frequently bought together these options:
Filter Options (when ordering with main unit)
Part #
Qty
Description
1200 VOM-(DRY)
0
1
2
3
4
5
6
7
8
9
10
Dry source option - 2" polyester prefilter, 12" deep main cartridge filter, 95%
1200 VOM-2C
0
1
2
3
4
5
6
7
8
9
10
2 charcoal after filter disposable with 4 lbs. charcoal.
1200 VOM-95DOP
0
1
2
3
4
5
6
7
8
9
10
Internal 95% DOP option: (1) 95% box filter (16 sq.ft.) and (1) 95% DOP filter in place of standard 95% main filter, 800 cfm. (Adds 15 lbs. to ship weight).
1200 VOM-AD
0
1
2
3
4
5
6
7
8
9
10
Internal adsorption option: (1) 95% box filter (16 sq.ft.), (1) refillable, v-bank absorber module (12 lbs. capacity), and (1) polyester after-filter in place of standard 95% filter, 800 cfm. (Adds 20 lbs. to ship weight).
1200 VOM-CV
0
1
2
3
4
5
6
7
8
9
10
Chevron option: 2 mesh prefilter followed by a 4 Chevron mist eliminator. Replaces standard impingement prefilter.
1200 VOM-EXAD
0
1
2
3
4
5
6
7
8
9
10
External adsorber module, 25 lbs. charcoal, 37.5 KMN04 not included 700 CFM, top discharge. (Adds 13 to height and 28 lbs. to ship weight.)
1200 VOM-EXDOP
0
1
2
3
4
5
6
7
8
9
10
External DOP filter 95% 700 CFM, top discharge. (Adds 13 to height and 38 lbs. to ship weight.)
1200 VOM-EXHE
0
1
2
3
4
5
6
7
8
9
10
External HEPA, 99.97%, 700 cfm, with top discharge. (Adds 13 to height and 40 lbs. to ship weight). For PG-6 use 2PG6-HEPA.
1200 VOM-HEPA
0
1
2
3
4
5
6
7
8
9
10
Internal 99.97% HEPA option: (1) 95% box filter (16 sq.ft.) and (1) 99.97% HEPA filter in place of standard 95% main filter, 800 cfm. (Adds 20 lbs. to ship weight).
Extraction Arms
Part #
Qty
Description
1200 VOM-6P05
0
1
2
3
4
5
6
7
8
9
10
5' long x 6 dia. positioner with mounting plate. (Add 30 lbs. to ship weight).
1200 VOM-6P08
0
1
2
3
4
5
6
7
8
9
10
8' long x 6 dia. positioner with mounting plate. (Add 35 lbs. to ship weight).
Variable Frequency Drives
Part #
Qty
Description
VFD-KIT-1HP-115-230-3
0
1
2
3
4
5
6
7
8
9
10
1HP 120-240V Hybrid VFD 1 Phase In, 230V 3 Phase Output 60Hz complete with:
VFD NEMA 4
1 HP Motor
Wiring
Labor
Re-certification
PLEASE NOTE: this kit is only required when upgrading a 120V system with a VFD
VFD-KIT-2HP-115-230-3
0
1
2
3
4
5
6
7
8
9
10
2HP 120-240V Hybrid VFD 1 Phase In, 230V 3 Phase Output 60Hz complete with:
VFD NEMA 4
2 HP Motor
Wiring
Labor
Re-certification
PLEASE NOTE: this kit is only required when upgrading a 120 or 220/1/60 V system with a VFD
VFD-KIT-3HP-220-230-3
0
1
2
3
4
5
6
7
8
9
10
3HP 240V Hybrid VFD 1 Phase In, 230V 3 Phase Output 60Hz complete with:
VFD NEMA 4
3 HP Motor
Wiring
Labor
Re-certification
PLEASE NOTE: this kit is only required when upgrading a 120V system with a VFD
Sound Attenuation
Part #
Qty
Description
1200 VOM-S-EXT
0
1
2
3
4
5
6
7
8
9
10
Silencer. (Adds 12 to height & 20 lbs. to ship weight).
Preventative Maintenance Pressure Gauges, etc. (when ordering main unit)
Part #
Qty
Description
LEV-MC-PG-5
0
1
2
3
4
5
6
7
8
9
10
Pressure Gauge - complete with Wall, Ceiling or table mounting bracket and 0-5 pressure gauge. 3/16 inside diameter tubing ordered separately.
PG-10
0
1
2
3
4
5
6
7
8
9
10
Pressure Gauge - complete with Wall, Ceiling or table mounting bracket and 0-10 pressure gauge. 3/16 inside diameter tubing ordered separately.
GET MY
INSTANT QUOTE
Name
Company
Email
Phone
Project
Comments
Technical Info Requested
Spec Drawing
Brochure
Case Study
Video
To make sure that you are a human being and not a robot, please also enter the letters you see below:
Enter letters above