Solutions for
Single Station
Single Station
Single Station
Here we show solutions for extracting MIST at source with the use of a dedicated filter/fan unit. Most of our customers who purchase these solutions do so because they either re-tool regularly, prefer a system without extensive ductwork and appreciate that this equipment can upgraded if the air quality legislation changes. The solution can also be re-applied to a new applications if the current process is eliminated, removing the need to alter ductwork and ensuring a long life span of the products. Please Note: as these filters are "SELF-DRAINING" it is important that the amount of dust being captured by these systems does not exceed more than 5% of the total extracted pollutant. If the dust quantity is kept to a minimum, filter life can be expected between 1 and 5 years depending on the application and runtime.
(03-01) DCH-1 - Heavy Duty Dusts & Smoke - Self cleaning filter system built in - 300 to 800 CFM - 6” Ø inlet **
_DCH-1_-_Heavy_Duty_Dusts_&_Smoke_-_Self_cleaning_filter_system_built_in_-_300_to_800_CFM_-_6_174/(03-01)_DCH-1_-_Heavy_Duty_Dusts_&_Smoke_-_Self_cleaning_filter_system_built_in_-_300_to_800_CFM_-_6.jpg)
Cartridge collector with (1) Clean 2® cartridge filter (150ft² of media each), manual VIBRA-PULSE® filter cleaning system, and 6" collar on top. Includes either a 5 gallon external dust drawer or 10 gallon pail and hopper.
Attachments
001 - Equipment Specification and Dimension Drawings:
002 - Brochures:
003 - Client Installations - Case Studies with Photos:
004 - Product Videos:
006 - Local Exhaust and Ventilation Duct 3D Layouts:
017 - LEV CAD Blocks (Auto CAD, RVT, SLDPRT):
(03-03) DCH-2 - Heavy Duty Dusts & Smoke - Self cleaning filter system built in - 600 to 1,200 CFM - 8” Ø inlet **
_DCH-2_-_Heavy_Duty_Dusts_&_Smoke_-_Self_cleaning_filter_system_built_in_-_600_to_1200_CFM_-__31/(03-03)_DCH-2_-_Heavy_Duty_Dusts_&_Smoke_-_Self_cleaning_filter_system_built_in_-_600_to_1200_CFM_-_.jpg)
Cartridge dust collector with (2) Clean 2® cartridge filter (150ft² of media each), manual VIBRA-PULSE® filter cleaning system, and 8" collar on top. Includes a 10 gallon external dust drawer or tray.
Attachments
001 - Equipment Specification and Dimension Drawings:
001a - How to Install (How to install local exhaust system, Isometric and Exploded Views):
002 - Brochures:
003 - Client Installations - Case Studies with Photos:
003a - Client Installations - Case Studies with Video:
004 - Product Videos:
006 - Local Exhaust and Ventilation Duct 3D Layouts:
017 - LEV CAD Blocks (Auto CAD, RVT, SLDPRT):
(03-05) WF - Weld Fume, Dusts & Gases - Cleanable filters - 300 to 1400 CFM - 6” Ø inlet **
_WF_-_Weld_Fume_Dusts_&_Gases_-_Cleanable_filters_-_300_to_1400_CFM_-_6”_Ø_inlet_574/(03-05)_WF_-_Weld_Fume_Dusts_&_Gases_-_Cleanable_filters_-_300_to_1400_CFM_-_6”_Ø_inlet.jpg)
Wall-mounted mechanical filter unit c/w direct mount P-Max fan. The unit comes standard with either a spun-bound polyester (washable) filter. Designed for use with extraction arms, and/or ducted applications.
Attachments
001 - Equipment Specification and Dimension Drawings:
001a - How to Install (How to install local exhaust system, Isometric and Exploded Views):
002 - Brochures:
003 - Client Installations - Case Studies with Photos:
004 - Product Videos:
006 - Local Exhaust and Ventilation Duct 3D Layouts:
017 - LEV CAD Blocks (Auto CAD, RVT, SLDPRT):
Buyer Guides:
(03-06) WFSC - Weld Fume, Dusts & Smoke - Self cleaning filter system built in - 300 to 800 CFM - 6” Ø inlet **
_WFSC_-_Weld_Fume_Dusts_&_Smoke_-_Self_cleaning_filter_system_built_in_-_300_to_800_CFM_-_6”__575/(03-06)_WFSC_-_Weld_Fume_Dusts_&_Smoke_-_Self_cleaning_filter_system_built_in_-_300_to_800_CFM_-_6”_.jpg)
Wall-mounted mechanical filter unit. The unit comes standard c/w Vibra-Pulse cleaning system, washable filter, hopper and 5 gallon drum. Designed for use with extraction arms, and/or ducted applications.600 CFM @ 4" w.g.
Attachments
001 - Equipment Specification and Dimension Drawings:
003 - Client Installations - Case Studies with Photos:
003a - Client Installations - Case Studies with Video:
(03-061) CF-ECO Welding Fume and Dust Filter. Self Cleaning system - 1400 CFM “Free-Blowing” Ø8'' Inlet **
_CF-ECO_Welding_Fume_and_Dust_Filter_Self_Cleaning_system_-_1400_CFM_“Free-Blowing”_Ø8''_Inl_704/(03-061)_CF-ECO_Welding_Fume_and_Dust_Filter_Self_Cleaning_system_-_1400_CFM_“Free-Blowing”_Ø8''_Inl.jpg)
CF-Eco is made for welding and soldering fume and lighter dust. It is equipped with self-cleaning cartridge filter and built in fan with an aluminium impeller.
Filtration: With up to 99,9% filter efficiency the CF-ECO. Cartridge Filters will clean the premises of welding fumes and light grinding dust. The cleaned air is recirculated into the premises, with no heat loss at all.
Filtration: With up to 99,9% filter efficiency the CF-ECO. Cartridge Filters will clean the premises of welding fumes and light grinding dust. The cleaned air is recirculated into the premises, with no heat loss at all.
Attachments
001 - Equipment Specification and Dimension Drawings:
002 - Brochures:
004 - Product Videos: