Solutions forPortable Filtration Equipment
Portable Filtration Equipment
(02-09) Mini Flex - (12''L x 13''W x 20''H, 2xØ3 inlet @ 100 CFM) **
_Mini_Flex_-_(12''L_x_13''W_x_20''H_2xØ3_inlet_@_100_CFM)_669/(02-09)_Mini_Flex_-_(12''L_x_13''W_x_20''H_2xØ3_inlet_@_100_CFM).png)
Soldering Fume Collector with a (1) 1" Poly Filter, (1) 99.97% HEPA filter, 1" charcoal filter, a 200 Watt motor, 115/1/60Hz (0.85 amps), and Aluminum Hood and 2 - 3" x 42" long hose.
Attachments
001 - Spec Drawings:
002 - Brochures:
Solutions forSingle Station
Single Station
(03-01) DCH-1 - Heavy Duty Dusts & Smoke - Self cleaning filter system built in - 300 to 800 CFM - 6” Ø inlet **
_DCH-1_-_Heavy_Duty_Dusts_&_Smoke_-_Self_cleaning_filter_system_built_in_-_300_to_800_CFM_-_6_174/(03-01)_DCH-1_-_Heavy_Duty_Dusts_&_Smoke_-_Self_cleaning_filter_system_built_in_-_300_to_800_CFM_-_6.jpg)
Cartridge collector with (1) Clean 2® cartridge filter (150ft² of media each), manual VIBRA-PULSE® filter cleaning system, and 6" collar on top. Includes either a 5 gallon external dust drawer or 10 gallon pail and hopper.
Attachments
001 - Spec Drawings:
002 - Brochures:
003 - Case Studies:
004 - Videos:
006 - System Layouts:
017 - DWG and RVT models:
Solutions forStationary Filtration Equipment
Stationary Filtration Equipment
(03-01) DCH-1 - Heavy Duty Dusts & Smoke - Self cleaning filter system built in - 300 to 800 CFM - 6” Ø inlet **
_DCH-1_-_Heavy_Duty_Dusts_&_Smoke_-_Self_cleaning_filter_system_built_in_-_300_to_800_CFM_-_6_174/(03-01)_DCH-1_-_Heavy_Duty_Dusts_&_Smoke_-_Self_cleaning_filter_system_built_in_-_300_to_800_CFM_-_6.jpg)
Cartridge collector with (1) Clean 2® cartridge filter (150ft² of media each), manual VIBRA-PULSE® filter cleaning system, and 6" collar on top. Includes either a 5 gallon external dust drawer or 10 gallon pail and hopper.
Attachments
001 - Spec Drawings:
002 - Brochures:
003 - Case Studies:
004 - Videos:
006 - System Layouts:
017 - DWG and RVT models:
Solutions forSingle Station
Single Station
(03-03) DCH-2 - Heavy Duty Dusts & Smoke - Self cleaning filter system built in - 600 to 1,200 CFM - 8” Ø inlet **
_DCH-2_-_Heavy_Duty_Dusts_&_Smoke_-_Self_cleaning_filter_system_built_in_-_600_to_1200_CFM_-__31/(03-03)_DCH-2_-_Heavy_Duty_Dusts_&_Smoke_-_Self_cleaning_filter_system_built_in_-_600_to_1200_CFM_-_.jpg)
Cartridge dust collector with (2) Clean 2® cartridge filter (150ft² of media each), manual VIBRA-PULSE® filter cleaning system, and 8" collar on top. Includes a 10 gallon external dust drawer or tray.
Attachments
0001 - Installation Examples - How products go together:
001 - Spec Drawings:
002 - Brochures:
003 - Case Studies:
003a - Video Case Study:
004 - Videos:
006 - System Layouts:
017 - DWG and RVT models:
Solutions forStationary Filtration Equipment
Stationary Filtration Equipment
(03-03) DCH-2 - Heavy Duty Dusts & Smoke - Self cleaning filter system built in - 600 to 1,200 CFM - 8” Ø inlet **
_DCH-2_-_Heavy_Duty_Dusts_&_Smoke_-_Self_cleaning_filter_system_built_in_-_600_to_1200_CFM_-__31/(03-03)_DCH-2_-_Heavy_Duty_Dusts_&_Smoke_-_Self_cleaning_filter_system_built_in_-_600_to_1200_CFM_-_.jpg)
Cartridge dust collector with (2) Clean 2® cartridge filter (150ft² of media each), manual VIBRA-PULSE® filter cleaning system, and 8" collar on top. Includes a 10 gallon external dust drawer or tray.
Attachments
0001 - Installation Examples - How products go together:
001 - Spec Drawings:
002 - Brochures:
003 - Case Studies:
003a - Video Case Study:
004 - Videos:
006 - System Layouts:
017 - DWG and RVT models:
Solutions forWall Mounted Air Cleaners
Wall Mounted Air Cleaners
(03-05) WF - Weld Fume, Dusts & Gases - Cleanable filters - 300 to 1400 CFM - 6” Ø inlet **
_WF_-_Weld_Fume_Dusts_&_Gases_-_Cleanable_filters_-_300_to_1400_CFM_-_6”_Ø_inlet_574/(03-05)_WF_-_Weld_Fume_Dusts_&_Gases_-_Cleanable_filters_-_300_to_1400_CFM_-_6”_Ø_inlet.jpg)
Wall-mounted mechanical filter unit c/w direct mount P-Max fan. The unit comes standard with either a spun-bound polyester (washable) filter. Designed for use with extraction arms, and/or ducted applications.
Attachments
001 - Spec Drawings:
001a - Spec Drawing - Installation Examples:
002 - Brochures:
003 - Case Studies:
004 - Videos:
006 - System Layouts:
017 - DWG and RVT models:
Buyer Guides:
Solutions forSingle Station
Single Station
(03-05) WF - Weld Fume, Dusts & Gases - Cleanable filters - 300 to 1400 CFM - 6” Ø inlet **
_WF_-_Weld_Fume_Dusts_&_Gases_-_Cleanable_filters_-_300_to_1400_CFM_-_6”_Ø_inlet_574/(03-05)_WF_-_Weld_Fume_Dusts_&_Gases_-_Cleanable_filters_-_300_to_1400_CFM_-_6”_Ø_inlet.jpg)
Wall-mounted mechanical filter unit c/w direct mount P-Max fan. The unit comes standard with either a spun-bound polyester (washable) filter. Designed for use with extraction arms, and/or ducted applications.
Attachments
001 - Spec Drawings:
001a - Spec Drawing - Installation Examples:
002 - Brochures:
003 - Case Studies:
004 - Videos:
006 - System Layouts:
017 - DWG and RVT models:
Buyer Guides:
Solutions forWall Mounted Air Cleaners
Wall Mounted Air Cleaners
(03-06) WFSC - Weld Fume, Dusts & Smoke - Self cleaning filter system built in - 300 to 800 CFM - 6” Ø inlet **
_WFSC_-_Weld_Fume_Dusts_&_Smoke_-_Self_cleaning_filter_system_built_in_-_300_to_800_CFM_-_6”__575/(03-06)_WFSC_-_Weld_Fume_Dusts_&_Smoke_-_Self_cleaning_filter_system_built_in_-_300_to_800_CFM_-_6”_.jpg)
Wall-mounted mechanical filter unit. The unit comes standard c/w Vibra-Pulse cleaning system, washable filter, hopper and 5 gallon drum. Designed for use with extraction arms, and/or ducted applications.600 CFM @ 4" w.g.
Attachments
001 - Spec Drawings:
003 - Case Studies:
003a - Video Case Study:
Solutions forSingle Station
Single Station
(03-06) WFSC - Weld Fume, Dusts & Smoke - Self cleaning filter system built in - 300 to 800 CFM - 6” Ø inlet **
_WFSC_-_Weld_Fume_Dusts_&_Smoke_-_Self_cleaning_filter_system_built_in_-_300_to_800_CFM_-_6”__575/(03-06)_WFSC_-_Weld_Fume_Dusts_&_Smoke_-_Self_cleaning_filter_system_built_in_-_300_to_800_CFM_-_6”_.jpg)
Wall-mounted mechanical filter unit. The unit comes standard c/w Vibra-Pulse cleaning system, washable filter, hopper and 5 gallon drum. Designed for use with extraction arms, and/or ducted applications.600 CFM @ 4" w.g.
Attachments
001 - Spec Drawings:
003 - Case Studies:
003a - Video Case Study:
Solutions forReplacement Filters for Dust Collectors
Replacement Filters for Dust Collectors
(04-99) Replacement filters for Dust Collectors and Air Cleaners
_Replacement_filters_for_Dust_Collectors_and_Air_Cleaners_234/(04-99)_Replacement_filters_for_Dust_Collectors_and_Air_Cleaners.jpg)
Replacement filters for a wide variety of filter units. Pls see below for more information... If you don't see the filter you need, please call, we probably have it...
Solutions forDown-Draft Tables for Ducted Exhaust or Filtration
Down-Draft Tables for Ducted Exhaust or Filtration
(05-01) EZ Bench - Light dusts - Washable and/or disposable filters - 36''W X 24''D (800 CFM)**
_EZ_Bench_-_Light_dusts_-_Washable_andor_disposable_filters_-_36''W_X_24''D_(800_CFM)_596/(05-01)_EZ_Bench_-_Light_dusts_-_Washable_andor_disposable_filters_-_36''W_X_24''D_(800_CFM).jpg)
Easy Bench – A 800 CFM (500 CFM with HEPA or AD Module)downdraft table designed for the operator. Standard desk height with full leg room for maximum comfort and concentration. Simple Source Capture. Removes dust, fumes, and odors, for a cleaner, healthier work environment, and
improved productivity for close, fine hand work. Easy Filter Access. Standard panels slide in and out from the front, with easy-seal magnetic covers.
improved productivity for close, fine hand work. Easy Filter Access. Standard panels slide in and out from the front, with easy-seal magnetic covers.
Attachments
001 - Spec Drawings:
002 - Brochures:
017 - DWG and RVT models:
Solutions forDowndraft with Filtration (Integrated into Turntable)
Downdraft with Filtration (Integrated into Turntable)
(05-01) EZ Bench - Light dusts - Washable and/or disposable filters - 36''W X 24''D (800 CFM)**
_EZ_Bench_-_Light_dusts_-_Washable_andor_disposable_filters_-_36''W_X_24''D_(800_CFM)_596/(05-01)_EZ_Bench_-_Light_dusts_-_Washable_andor_disposable_filters_-_36''W_X_24''D_(800_CFM).jpg)
Easy Bench – A 800 CFM (500 CFM with HEPA or AD Module)downdraft table designed for the operator. Standard desk height with full leg room for maximum comfort and concentration. Simple Source Capture. Removes dust, fumes, and odors, for a cleaner, healthier work environment, and
improved productivity for close, fine hand work. Easy Filter Access. Standard panels slide in and out from the front, with easy-seal magnetic covers.
improved productivity for close, fine hand work. Easy Filter Access. Standard panels slide in and out from the front, with easy-seal magnetic covers.
Attachments
001 - Spec Drawings:
002 - Brochures:
017 - DWG and RVT models:
(05-02) SS-C-DT Wet Collector with Downdraft table
_SS-C-DT_Wet_Collector_with_Downdraft_table_876/(05-02)_SS-C-DT_Wet_Collector_with_Downdraft_table.jpg)
The SS-C series Downdraft Tables are self-contained workstations that come complete with water dust collection systems. Ideal for "cell manufacturing". They feature:Stainless steel construction Easy installation Adjustable work surface heights Regain air Ready to use
The workstation is available with a single work surface or with two work surfaces, one on each side
The SS-C series downdraft table allows for the dust to be immediately wetted, reducing the risk of fire in ductwork . The standard unit includes an aluminum perforated work surface, Adjustable table height and Regain Air Curtain in front to prevent dust from escaping the work zone.
Flow and electrical specification: 2500 CFM, motor 5 HP, 208-230/460/575 V/3/60
The workstation is available with a single work surface or with two work surfaces, one on each side
The SS-C series downdraft table allows for the dust to be immediately wetted, reducing the risk of fire in ductwork . The standard unit includes an aluminum perforated work surface, Adjustable table height and Regain Air Curtain in front to prevent dust from escaping the work zone.
Flow and electrical specification: 2500 CFM, motor 5 HP, 208-230/460/575 V/3/60
Solutions forDown-Draft Tables for Ducted Exhaust or Filtration
Down-Draft Tables for Ducted Exhaust or Filtration
(05-03) DTH800 - Heavy dusts & smoke - Self cleaning filter system built in - 24''D X 32’’W (800 CFM)* **
_DTH800_-_Heavy_dusts_&_smoke_-_Self_cleaning_filter_system_built_in_-_24''D_X_32’’W_(800_CFM_23/(05-03)_DTH800_-_Heavy_dusts_&_smoke_-_Self_cleaning_filter_system_built_in_-_24''D_X_32’’W_(800_CFM.jpg)
pre-engineered downdraft table complete with 1 Clean 2® 150 ft2 cartridge filter, integrated fan with TEFC direct drive class II motor and external dust tray generating 800 CFM with 150 FPM downdraft velocity. The DTH-800 draws contaminants away from workers’ breathing zone without hindering movement making these tables an ideal solutions for most welding and light dust/smoke applications.
Attachments
001 - Spec Drawings:
002 - Brochures:
003 - Case Studies:
004 - Videos:
017 - DWG and RVT models:
Buyer Guides:
Solutions forDowndraft with Filtration (Integrated into Turntable)
Downdraft with Filtration (Integrated into Turntable)
(05-03) DTH800 - Heavy dusts & smoke - Self cleaning filter system built in - 24''D X 32’’W (800 CFM)* **
_DTH800_-_Heavy_dusts_&_smoke_-_Self_cleaning_filter_system_built_in_-_24''D_X_32’’W_(800_CFM_23/(05-03)_DTH800_-_Heavy_dusts_&_smoke_-_Self_cleaning_filter_system_built_in_-_24''D_X_32’’W_(800_CFM.jpg)
pre-engineered downdraft table complete with 1 Clean 2® 150 ft2 cartridge filter, integrated fan with TEFC direct drive class II motor and external dust tray generating 800 CFM with 150 FPM downdraft velocity. The DTH-800 draws contaminants away from workers’ breathing zone without hindering movement making these tables an ideal solutions for most welding and light dust/smoke applications.
Attachments
001 - Spec Drawings:
002 - Brochures:
003 - Case Studies:
004 - Videos:
017 - DWG and RVT models:
Buyer Guides:
Solutions forDown-Draft Tables for Ducted Exhaust or Filtration
Down-Draft Tables for Ducted Exhaust or Filtration
(05-04) DTH1700 - Heavy dusts & smoke - Self cleaning filter system built in - 24''D X 48’’W (1,700 CFM)* **
_DTH1700_-_Heavy_dusts_&_smoke_-_Self_cleaning_filter_system_built_in_-_24''D_X_48’’W_(1700_C_49/(05-04)_DTH1700_-_Heavy_dusts_&_smoke_-_Self_cleaning_filter_system_built_in_-_24''D_X_48’’W_(1700_C.jpg)
The DTH-1700 is a Self-Contained pre-engineered Down Draft table comes complete with an integrated Fan and filtration system in addition to it's 24"D X 48"W work surface and 18" tall removable side & back shields generating 1400 CFM with 208 FPM downdraft velocity. The DTH-1700 draws contaminants away from workers’ breathing zone without hindering movement; large work area meets range of applications. Its use of (2) CLEAN-2 cartridge filters and the manual VIBRA-PULSE filter cleaning system makes this unit the ideal solution for most welding and light dust/smoke applications.
Attachments
001 - Spec Drawings:
002 - Brochures:
003 - Case Studies:
004 - Videos:
017 - DWG and RVT models:
Buyer Guides:
Solutions forDowndraft with Filtration (Integrated into Turntable)
Downdraft with Filtration (Integrated into Turntable)
(05-04) DTH1700 - Heavy dusts & smoke - Self cleaning filter system built in - 24''D X 48’’W (1,700 CFM)* **
_DTH1700_-_Heavy_dusts_&_smoke_-_Self_cleaning_filter_system_built_in_-_24''D_X_48’’W_(1700_C_49/(05-04)_DTH1700_-_Heavy_dusts_&_smoke_-_Self_cleaning_filter_system_built_in_-_24''D_X_48’’W_(1700_C.jpg)
The DTH-1700 is a Self-Contained pre-engineered Down Draft table comes complete with an integrated Fan and filtration system in addition to it's 24"D X 48"W work surface and 18" tall removable side & back shields generating 1400 CFM with 208 FPM downdraft velocity. The DTH-1700 draws contaminants away from workers’ breathing zone without hindering movement; large work area meets range of applications. Its use of (2) CLEAN-2 cartridge filters and the manual VIBRA-PULSE filter cleaning system makes this unit the ideal solution for most welding and light dust/smoke applications.
Attachments
001 - Spec Drawings:
002 - Brochures:
003 - Case Studies:
004 - Videos:
017 - DWG and RVT models:
Buyer Guides:
Solutions forDown-Draft Tables for Ducted Exhaust or Filtration
Down-Draft Tables for Ducted Exhaust or Filtration
(05-05) DT3000V2 - Heavy dusts & smoke - Self cleaning filter system built in - 42''D X 66’’W or 42'' X 96 (3,000-4500 CFM)**
_DT3000V2_-_Heavy_dusts_&_smoke_-_Self_cleaning_filter_system_built_in_-_42''D_X_66’’W_or_42'_373/(05-05)_DT3000V2_-_Heavy_dusts_&_smoke_-_Self_cleaning_filter_system_built_in_-_42''D_X_66’’W_or_42'.jpg)
The DT3000 is a completely self-contained pre-engineered Downdraft table. Comes complete with an integrated 3HP or 5HP energy saving blower, high efficiency cartridge filters and automatic self-cleaning system. Available in 2 standard sizes: 66" X 42" or 96 X 42" work surfaces at heights of 33".
The DT3000 draws contaminants away from workers’ breathing zone without hindering movement; and allowing the workers to work/walk around all sides of the table. The DT-3000 uses (6) CLEAN-2 ULTRA high efficiency cartridge filters (150 SQ. FT. of media each / 900 SQ. FT. total) and the VIBRA-PULSE filter cleaning system allows those filters to be cleaned in place when they become saturated. All you have to do is activated the cleaning system and empty the tray.
One of 2 powerful fan/motor combinations generate between 3000 and 4500 CFM.
This solution is ideal for most welding, Grinding and cutting applications.
The DT3000 draws contaminants away from workers’ breathing zone without hindering movement; and allowing the workers to work/walk around all sides of the table. The DT-3000 uses (6) CLEAN-2 ULTRA high efficiency cartridge filters (150 SQ. FT. of media each / 900 SQ. FT. total) and the VIBRA-PULSE filter cleaning system allows those filters to be cleaned in place when they become saturated. All you have to do is activated the cleaning system and empty the tray.
One of 2 powerful fan/motor combinations generate between 3000 and 4500 CFM.
This solution is ideal for most welding, Grinding and cutting applications.
Attachments
001 - Spec Drawings:
002 - Brochures:
003 - Case Studies:
004 - Videos:
017 - DWG and RVT models:
Buyer Guides:
Solutions forDowndraft with Filtration (Integrated into Turntable)
Downdraft with Filtration (Integrated into Turntable)
(05-05) DT3000V2 - Heavy dusts & smoke - Self cleaning filter system built in - 42''D X 66’’W or 42'' X 96 (3,000-4500 CFM)**
_DT3000V2_-_Heavy_dusts_&_smoke_-_Self_cleaning_filter_system_built_in_-_42''D_X_66’’W_or_42'_373/(05-05)_DT3000V2_-_Heavy_dusts_&_smoke_-_Self_cleaning_filter_system_built_in_-_42''D_X_66’’W_or_42'.jpg)
The DT3000 is a completely self-contained pre-engineered Downdraft table. Comes complete with an integrated 3HP or 5HP energy saving blower, high efficiency cartridge filters and automatic self-cleaning system. Available in 2 standard sizes: 66" X 42" or 96 X 42" work surfaces at heights of 33".
The DT3000 draws contaminants away from workers’ breathing zone without hindering movement; and allowing the workers to work/walk around all sides of the table. The DT-3000 uses (6) CLEAN-2 ULTRA high efficiency cartridge filters (150 SQ. FT. of media each / 900 SQ. FT. total) and the VIBRA-PULSE filter cleaning system allows those filters to be cleaned in place when they become saturated. All you have to do is activated the cleaning system and empty the tray.
One of 2 powerful fan/motor combinations generate between 3000 and 4500 CFM.
This solution is ideal for most welding, Grinding and cutting applications.
The DT3000 draws contaminants away from workers’ breathing zone without hindering movement; and allowing the workers to work/walk around all sides of the table. The DT-3000 uses (6) CLEAN-2 ULTRA high efficiency cartridge filters (150 SQ. FT. of media each / 900 SQ. FT. total) and the VIBRA-PULSE filter cleaning system allows those filters to be cleaned in place when they become saturated. All you have to do is activated the cleaning system and empty the tray.
One of 2 powerful fan/motor combinations generate between 3000 and 4500 CFM.
This solution is ideal for most welding, Grinding and cutting applications.
Attachments
001 - Spec Drawings:
002 - Brochures:
003 - Case Studies:
004 - Videos:
017 - DWG and RVT models:
Buyer Guides:
Solutions forDown-Draft Tables for Ducted Exhaust or Filtration
Down-Draft Tables for Ducted Exhaust or Filtration
(05-06) ALH1 Aluminum Dust NFPA - 24''D X 32’’W (800 CFM); 24''D X 48’’W (1,700 CFM)**
_ALH1_Aluminum_Dust_NFPA_-_24''D_X_32’’W_(800_CFM)_24''D_X_48’’W_(1700_CFM)_91/(05-06)_ALH1_Aluminum_Dust_NFPA_-_24''D_X_32’’W_(800_CFM)_24''D_X_48’’W_(1700_CFM).jpg)
Downdraft table that Meets NFPA 651 for processing and finishing aluminum when properly used and maintained.
Integral Collection Area and Work Surface Draws contaminants away from workers' breathing zone without hindering movement, open work area meets range of applicationsDirect-Drive Blower: Higher static pressure, longer filter life and greater reliability; no belts or pulleys to replace.
Non-electrostatic Operation: High reliability, low maintenance.
Ultra-Seal® Filter Mounting: Eliminates contaminant bypass of filters.
Optional Casters: 5" casters and 8" wheels for portability.
Ergonomic Cabinet: Easy access speeds filter change out and maintenance.
800 CFM (150 FPM downdraft velocity)
Electrical meets NFPA Division II, group-E for aluminum dust.
Integral Collection Area and Work Surface Draws contaminants away from workers' breathing zone without hindering movement, open work area meets range of applications
Attachments
001 - Spec Drawings:
002 - Brochures:
003 - Case Studies:
004 - Videos:
017 - DWG and RVT models:
Solutions forDowndraft with Filtration (Integrated into Turntable)
Downdraft with Filtration (Integrated into Turntable)
(05-06) ALH1 Aluminum Dust NFPA - 24''D X 32’’W (800 CFM); 24''D X 48’’W (1,700 CFM)**
_ALH1_Aluminum_Dust_NFPA_-_24''D_X_32’’W_(800_CFM)_24''D_X_48’’W_(1700_CFM)_91/(05-06)_ALH1_Aluminum_Dust_NFPA_-_24''D_X_32’’W_(800_CFM)_24''D_X_48’’W_(1700_CFM).jpg)
Downdraft table that Meets NFPA 651 for processing and finishing aluminum when properly used and maintained.
Integral Collection Area and Work Surface Draws contaminants away from workers' breathing zone without hindering movement, open work area meets range of applicationsDirect-Drive Blower: Higher static pressure, longer filter life and greater reliability; no belts or pulleys to replace.
Non-electrostatic Operation: High reliability, low maintenance.
Ultra-Seal® Filter Mounting: Eliminates contaminant bypass of filters.
Optional Casters: 5" casters and 8" wheels for portability.
Ergonomic Cabinet: Easy access speeds filter change out and maintenance.
800 CFM (150 FPM downdraft velocity)
Electrical meets NFPA Division II, group-E for aluminum dust.
Integral Collection Area and Work Surface Draws contaminants away from workers' breathing zone without hindering movement, open work area meets range of applications
Attachments
001 - Spec Drawings:
002 - Brochures:
003 - Case Studies:
004 - Videos:
017 - DWG and RVT models:
Solutions forDown-Draft Tables for Ducted Exhaust or Filtration
Down-Draft Tables for Ducted Exhaust or Filtration
(05-07) ALH2 (24''D X 48''W @ 1700 CFM)
_ALH2_(24''D_X_48''W_@_1700_CFM)_119/(05-07)_ALH2_(24''D_X_48''W_@_1700_CFM).jpg)
1400 CFM (175 FPM downdraft velocity) Downdraft table to collect aluminum dust., 24”Dx49”W, aluminum work surface, 14” side shields, removable dust tray. 3HP, 230-460/575-600/3/60HZ. Electrical meets NFPA Division II, group-E for aluminum dust.
Attachments
001 - Spec Drawings:
002 - Brochures:
003 - Case Studies:
004 - Videos:
017 - DWG and RVT models:
Solutions forDowndraft with Filtration (Integrated into Turntable)
Downdraft with Filtration (Integrated into Turntable)
(05-07) ALH2 (24''D X 48''W @ 1700 CFM)
_ALH2_(24''D_X_48''W_@_1700_CFM)_119/(05-07)_ALH2_(24''D_X_48''W_@_1700_CFM).jpg)
1400 CFM (175 FPM downdraft velocity) Downdraft table to collect aluminum dust., 24”Dx49”W, aluminum work surface, 14” side shields, removable dust tray. 3HP, 230-460/575-600/3/60HZ. Electrical meets NFPA Division II, group-E for aluminum dust.
Attachments
001 - Spec Drawings:
002 - Brochures:
003 - Case Studies:
004 - Videos:
017 - DWG and RVT models:
Solutions forDown-Draft Tables for Ducted Exhaust or Filtration
Down-Draft Tables for Ducted Exhaust or Filtration
(05-08) AL6 Aluminum Dust NFPA - 42''D X 66''W (+ 3,000 CFM)**
_AL6_Aluminum_Dust_NFPA_-_42''D_X_66''W_(+_3000_CFM)_372/(05-08)_AL6_Aluminum_Dust_NFPA_-_42''D_X_66''W_(+_3000_CFM).jpg)
3000 CFM heavy duty downdraft table to collect aluminum dust with its 42"D x 66"W work surface at a height of 33". This unit boasts 155 fpm downdraft velocity and includes 18" tall aluminum side and back shields. Self-contained pre-engineered downdraft table to allow for maximum, precise and energy efficient capture. Unit includes: Filtration efficiency of 99% @ 1 micron, front door for easy access to filters, and a preventative Pressure Gauge to be able to maintain and monitor the filters status, all backed by the ULTRACLEAN-PLUS™ cartridge filters (150 sq. ft. of media each)
Attachments
001 - Spec Drawings:
002 - Brochures:
017 - DWG and RVT models:
Solutions forDowndraft with Filtration (Integrated into Turntable)
Downdraft with Filtration (Integrated into Turntable)
(05-08) AL6 Aluminum Dust NFPA - 42''D X 66''W (+ 3,000 CFM)**
_AL6_Aluminum_Dust_NFPA_-_42''D_X_66''W_(+_3000_CFM)_372/(05-08)_AL6_Aluminum_Dust_NFPA_-_42''D_X_66''W_(+_3000_CFM).jpg)
3000 CFM heavy duty downdraft table to collect aluminum dust with its 42"D x 66"W work surface at a height of 33". This unit boasts 155 fpm downdraft velocity and includes 18" tall aluminum side and back shields. Self-contained pre-engineered downdraft table to allow for maximum, precise and energy efficient capture. Unit includes: Filtration efficiency of 99% @ 1 micron, front door for easy access to filters, and a preventative Pressure Gauge to be able to maintain and monitor the filters status, all backed by the ULTRACLEAN-PLUS™ cartridge filters (150 sq. ft. of media each)
Attachments
001 - Spec Drawings:
002 - Brochures:
017 - DWG and RVT models:
(05-09) WETREX single & dual Wet Tables - Explosive Dust - Table Qty, sizes & flow to suit
_WETREX_single_&_dual_Wet_Tables_-_Explosive_Dust_-_Table_Qty_sizes_&_flow_to_suit_131/(05-09)_WETREX_single_&_dual_Wet_Tables_-_Explosive_Dust_-_Table_Qty_sizes_&_flow_to_suit.jpg)
The WETREX Downdraft Table is a self-contained workstation with its own water dust collection system, excellent for "cell manufacturing." It features easy installation and comes ready to run. The workstation is available with a single work surface or with two work surfaces, one on each side.
The WETREX gets the dust immediately wetted, reducing the risk of fire in ductwork and meets OSHA and NFPA regulations for dust collectors located inside the building. The standard unit includes a fiberglass grated work surface, and optional Regain Air Curtain in front to prevent dust from escaping the work zone.
The WETREX gets the dust immediately wetted, reducing the risk of fire in ductwork and meets OSHA and NFPA regulations for dust collectors located inside the building. The standard unit includes a fiberglass grated work surface, and optional Regain Air Curtain in front to prevent dust from escaping the work zone.
Attachments
001 - Spec Drawings:
002 - Brochures:
003 - Case Studies:
007 - Written Specifications:
017 - DWG and RVT models:
(05-11) DT-23 General Purpose - 24''D x 36''W (flow to suit)**
_DT-23_General_Purpose_-_24''D_x_36''W_(flow_to_suit)_194/(05-11)_DT-23_General_Purpose_-_24''D_x_36''W_(flow_to_suit).jpg)
Non-Powered Down Draft table complete with integrated collection area and 2' X 3' work surface. Draws contaminants away from workers’ breathing zone without hindering movement.
Attachments
001 - Spec Drawings:
002 - Brochures:
004 - Videos:
007 - Written Specifications:
017 - DWG and RVT models:
(05-12) DT-35 (60''W x 36''D – flow to suit) **
_DT-35_(60''W_x_36''D_–_flow_to_suit)_50/(05-12)_DT-35_(60''W_x_36''D_–_flow_to_suit).jpg)
Non-Powered Down Draft table complete with integrated collection area and 3' X 5' work surface. Draws contaminants away from workers’ breathing zone without hindering movement.
Attachments
001 - Spec Drawings:
002 - Brochures:
003 - Case Studies:
004 - Videos:
017 - DWG and RVT models:
Solutions forDown-Draft Tables for Ducted Exhaust or Filtration
Down-Draft Tables for Ducted Exhaust or Filtration
(05-15) Sledgehammer Series Downdraft Tables **
_Sledgehammer_Series_Downdraft_Tables_703/(05-15)_Sledgehammer_Series_Downdraft_Tables.jpg)
The 'Sledgehammer' © series downdraft tables are designed to be a dual purpose Work station and Extraction solution.
These tables draw contaminants away from workers’ breathing zone without hindering movement. Additionally, they provide a the most durable ¼” steel plate work surface (36” X 24”) on the market. Hence the name “Sledgehammer” ©
The SLEDGEHAMMER is equipped with Jet-Pulse Cleaning that allows simple cleaning of the filter, which reduces filter costs dramatically*.
Applications Include filtering of contaminants from the following applications: welding, grinding, de-burring, plastics, composites, sampling, batching, weighing, soldering, and finishing processes
All contaminated air is filtered and returned to the facility.
Please select filter options according to your application… when proper filters are selected, all ‘’Sledgehammer’’ © series downdraft tables comply to all Local and Federal clean air requirements.
Need a larger work surface? Quite often the area at which the fume or contaminant is generated is much smaller than the work table required… In these cases, either place the “sledgehammer” © series table in the middle of 2 or more work tables or bolt multiple downdraft tables together (Contact your distributor for quantity discounts).
These tables draw contaminants away from workers’ breathing zone without hindering movement. Additionally, they provide a the most durable ¼” steel plate work surface (36” X 24”) on the market. Hence the name “Sledgehammer” ©
The SLEDGEHAMMER is equipped with Jet-Pulse Cleaning that allows simple cleaning of the filter, which reduces filter costs dramatically*.
Applications Include filtering of contaminants from the following applications: welding, grinding, de-burring, plastics, composites, sampling, batching, weighing, soldering, and finishing processes
All contaminated air is filtered and returned to the facility.
Please select filter options according to your application… when proper filters are selected, all ‘’Sledgehammer’’ © series downdraft tables comply to all Local and Federal clean air requirements.
Need a larger work surface? Quite often the area at which the fume or contaminant is generated is much smaller than the work table required… In these cases, either place the “sledgehammer” © series table in the middle of 2 or more work tables or bolt multiple downdraft tables together (Contact your distributor for quantity discounts).
Attachments
001 - Spec Drawings:
002 - Brochures:
Buyer Guides:
Solutions forDowndraft with Filtration (Integrated into Turntable)
Downdraft with Filtration (Integrated into Turntable)
(05-15) Sledgehammer Series Downdraft Tables **
_Sledgehammer_Series_Downdraft_Tables_703/(05-15)_Sledgehammer_Series_Downdraft_Tables.jpg)
The 'Sledgehammer' © series downdraft tables are designed to be a dual purpose Work station and Extraction solution.
These tables draw contaminants away from workers’ breathing zone without hindering movement. Additionally, they provide a the most durable ¼” steel plate work surface (36” X 24”) on the market. Hence the name “Sledgehammer” ©
The SLEDGEHAMMER is equipped with Jet-Pulse Cleaning that allows simple cleaning of the filter, which reduces filter costs dramatically*.
Applications Include filtering of contaminants from the following applications: welding, grinding, de-burring, plastics, composites, sampling, batching, weighing, soldering, and finishing processes
All contaminated air is filtered and returned to the facility.
Please select filter options according to your application… when proper filters are selected, all ‘’Sledgehammer’’ © series downdraft tables comply to all Local and Federal clean air requirements.
Need a larger work surface? Quite often the area at which the fume or contaminant is generated is much smaller than the work table required… In these cases, either place the “sledgehammer” © series table in the middle of 2 or more work tables or bolt multiple downdraft tables together (Contact your distributor for quantity discounts).
These tables draw contaminants away from workers’ breathing zone without hindering movement. Additionally, they provide a the most durable ¼” steel plate work surface (36” X 24”) on the market. Hence the name “Sledgehammer” ©
The SLEDGEHAMMER is equipped with Jet-Pulse Cleaning that allows simple cleaning of the filter, which reduces filter costs dramatically*.
Applications Include filtering of contaminants from the following applications: welding, grinding, de-burring, plastics, composites, sampling, batching, weighing, soldering, and finishing processes
All contaminated air is filtered and returned to the facility.
Please select filter options according to your application… when proper filters are selected, all ‘’Sledgehammer’’ © series downdraft tables comply to all Local and Federal clean air requirements.
Need a larger work surface? Quite often the area at which the fume or contaminant is generated is much smaller than the work table required… In these cases, either place the “sledgehammer” © series table in the middle of 2 or more work tables or bolt multiple downdraft tables together (Contact your distributor for quantity discounts).
Attachments
001 - Spec Drawings:
002 - Brochures:
Buyer Guides:
Solutions forDown-Draft Tables for Ducted Exhaust or Filtration
Down-Draft Tables for Ducted Exhaust or Filtration
(05-17) Polijet - Downdraft Table with cartridge filters **
_Polijet_-_Downdraft_Table_with_cartridge_filters_909/(05-17)_Polijet_-_Downdraft_Table_with_cartridge_filters.png)
Solutions forDowndraft with Filtration (Integrated into Turntable)
Downdraft with Filtration (Integrated into Turntable)
(05-17) Polijet - Downdraft Table with cartridge filters **
_Polijet_-_Downdraft_Table_with_cartridge_filters_909/(05-17)_Polijet_-_Downdraft_Table_with_cartridge_filters.png)
Solutions forCanopy/Receiving Hoods
Canopy/Receiving Hoods
(07-01) LEV Overhead Hoods - Smoke - Washable and/or disposable filters - 4’X4’ to 12’X20’ (flow to suit)**
_LEV_Overhead_Hoods_-_Smoke_-_Washable_andor_disposable_filters_-_4’X4’_to_12’X20’_(flow_to_s_613/(07-01)_LEV_Overhead_Hoods_-_Smoke_-_Washable_andor_disposable_filters_-_4’X4’_to_12’X20’_(flow_to_s.jpg)
The LEV-Hood is a pre-engineered ventilation hood that completes with filters and fan. This ''Plug & Play'' design is ready to mount as a "free-hanging" system above a welding cell or work table and will collect/filter the smoke, fumes generated from a variety of industrial processes. The cleaned air is then re-circulated to the plant delivering additional energy savings and environmental benefits.
Most Systems can be put in position with minimal mechanical installation time, typical 2 hours/2 men per hood. Electrical motor and lighting connections are also required.
This is an excellent solution when at-the-source capture of pollutants is not possible, practical or convenient. Simply put this is a nice quiet efficient and effective air filtration system.
A high efficiency, 3-stage filtration system. The first stage of filtration is a 2" baffle filter used for spark arrestance. The 2nd stage is a 40% pleated pre-filter that will trap dust and larger particles . The 3rd stage is a 95% micro-glass multi-pocket bag filter that will remove smoke and other sub-micron size particles from the air.
Most Systems can be put in position with minimal mechanical installation time, typical 2 hours/2 men per hood. Electrical motor and lighting connections are also required.
This is an excellent solution when at-the-source capture of pollutants is not possible, practical or convenient. Simply put this is a nice quiet efficient and effective air filtration system.
A high efficiency, 3-stage filtration system. The first stage of filtration is a 2" baffle filter used for spark arrestance. The 2nd stage is a 40% pleated pre-filter that will trap dust and larger particles . The 3rd stage is a 95% micro-glass multi-pocket bag filter that will remove smoke and other sub-micron size particles from the air.
Attachments
001 - Spec Drawings:
002 - Brochures:
003 - Case Studies:
017 - DWG and RVT models:
Solutions forMounted Filters with Integrated Extraction Arms & Fan
Mounted Filters with Integrated Extraction Arms & Fan
(07-02) F91 Suspended System with Extraction Arms - Smoke & Dust - 1 or 2 Arms 7'' Ø (650-1,300 CFM)* **
_F91_Suspended_System_with_Extraction_Arms_-_Smoke_&_Dust_-_1_or_2_Arms_7''_Ø_(650-1300_CFM)_61/(07-02)_F91_Suspended_System_with_Extraction_Arms_-_Smoke_&_Dust_-_1_or_2_Arms_7''_Ø_(650-1300_CFM).jpg)
Source capture, single arm unit, 2” mesh pre-filter, 95% bag main filter, single arm inlet plenum, 10’ long, E-Z ARM® overhead self-supporting pickup arm. Rated 1200 CFM. Includes Class II B.I. blower direct drive, 3 HP motor, 3ø
Attachments
001 - Spec Drawings:
002 - Brochures:
004 - Videos:
017 - DWG and RVT models:
(07-03) F122 Suspended System with Extraction Arms - Smoke & Dust - 1 or 2 Arms 7'' Ø (1,000-2,000 CFM)**
_F122_Suspended_System_with_Extraction_Arms_-_Smoke_&_Dust_-_1_or_2_Arms_7''_Ø_(1000-2000_CFM_89/(07-03)_F122_Suspended_System_with_Extraction_Arms_-_Smoke_&_Dust_-_1_or_2_Arms_7''_Ø_(1000-2000_CFM.jpg)
Source capture, dual arm unit, includes model F120- 2AL-95 unit, inlet plenum and 2 pickup arms E-Z ARM® x 10’ long self-supporting, 2000 CFM. Includes Class II B.I. blower and direct drive 3 HP motor.
Attachments
001 - Spec Drawings:
002 - Brochures:
004 - Videos:
017 - DWG and RVT models:
(07-04) HC4 Suspended System with Extraction Arms/Self cleaning filters - Smoke & Dust - 1 or 2 Arms 7'' Ø (1,000-2,000 CFM)**
_HC4_Suspended_System_with_Extraction_ArmsSelf_cleaning_filters_-_Smoke_&_Dust_-_1_or_2_Arms__88/(07-04)_HC4_Suspended_System_with_Extraction_ArmsSelf_cleaning_filters_-_Smoke_&_Dust_-_1_or_2_Arms_.jpg)
Horizontal cartridge collector w/4 Clean-2® cartridge filters (150ft² of media each). Comes complete with either DUAL inlets or (2) 10’ long E-Z Arm® high flow extractors (with damper and light in hood), AUTO-CLEAN VIBRA-PULSE® filter cleaning system, a 3 HP TEFC motor and a ½” NPT regulator. 2000 CFM
Attachments
001 - Spec Drawings:
002 - Brochures:
003 - Case Studies:
004 - Videos:
017 - DWG and RVT models:
(07-05) HC-4-Flexi **
_HC-4-Flexi_235/(07-05)_HC-4-Flexi.jpg)
Horizontal cartridge collector w/4 Clean-2® filter cartridges. Comes prepared to accept up to 4 Flexi© Extractor Arms (ordered separately), which allows for excellent extraction right at source. This solution is ideal when a packaged "Pre-engineered" solution is required. Suitable for most welding and light dust applications.
Attachments
001 - Spec Drawings:
(07-06) Extraction Rails
_Extraction_Rails_666/(07-06)_Extraction_Rails.jpg)
f
Solutions forCanopy/Receiving Hoods
Canopy/Receiving Hoods
(07-08) Canopy Hoods for CNC Machines
_Canopy_Hoods_for_CNC_Machines_900/(07-08)_Canopy_Hoods_for_CNC_Machines.png)
Canopy Hoods are a pre-engineered hood that encloses a CNC or similar machine to allow for the capture of dust and fumes.
Solutions forPortable Filtration Equipment
Portable Filtration Equipment
(08-01) Fume/Booth - Odors and Lights dusts - 2’ X 2’ Opening (230 CFM)**
_FumeBooth_-_Odors_and_Lights_dusts_-_2’_X_2’_Opening_(230_CFM)_441/(08-01)_FumeBooth_-_Odors_and_Lights_dusts_-_2’_X_2’_Opening_(230_CFM).jpg)
A ductless, portable desktop and bench top system for the removal of fumes, dust, smoke, odors and gases in a compact design.
Attachments
001 - Spec Drawings:
002 - Brochures:
003a - Video Case Study:
004 - Videos:
017 - DWG and RVT models:
Solutions forFlush Mounted (Ceiling) Air Cleaners
Flush Mounted (Ceiling) Air Cleaners
(09-10) FM600 Commercial - Dust & Odors - Washable and/or disposable filters - 2’ X 2’ T - Bar Mount (600 CFM)* **
_FM600_Commercial_-_Dust_&_Odors_-_Washable_andor_disposable_filters_-_2’_X_2’_T_-_Bar_Mount__69/(09-10)_FM600_Commercial_-_Dust_&_Odors_-_Washable_andor_disposable_filters_-_2’_X_2’_T_-_Bar_Mount_.jpg)
600 CFM Flush Mount Unit. Fits in a standard 2’ x 2’ ceiling tile opening. Includes (1) ½” aluminum mesh pre-filter, (1) 95% main filter (14ft²), (1) ½” charcoal after-filter and an ODOR/EX deodorizer.
Attachments
001 - Spec Drawings:
002 - Brochures:
017 - DWG and RVT models:
(09-11) FM1000 Commercial - Dust & Odors - Washable and/or disposable filters - 2’ X 4’ T - Bar Mount (1,000 CFM)* **
_FM1000_Commercial_-_Dust_&_Odors_-_Washable_andor_disposable_filters_-_2’_X_4’_T_-_Bar_Mount_82/(09-11)_FM1000_Commercial_-_Dust_&_Odors_-_Washable_andor_disposable_filters_-_2’_X_4’_T_-_Bar_Mount.jpg)
Flush mount 1000 CFM units, fits in 2 x 4 ceiling tile.
Attachments
001 - Spec Drawings:
002 - Brochures:
017 - DWG and RVT models:
Solutions for“On-Jig"
“On-Jig"
(12-01) Porta-Flex - Weld Fume - Washable and/or Disposable Filters - (125 & 250 CFM)
_Porta-Flex_-_Weld_Fume_-_Washable_andor_Disposable_Filters_-_(125_&_250_CFM)_507/(12-01)_Porta-Flex_-_Weld_Fume_-_Washable_andor_Disposable_Filters_-_(125_&_250_CFM).jpg)
At 28 lbs., these light weight units will go anywhere. Designed for use in confined spaces and areas where portability is a must. The one-man portable unit quickly removes harmful airborne smoke and particulate from the breathing and work zone through the 8' flexible hose and optional positioning arm and nozzles with magnetic base. The large selection of filter combinations allow these units to effectively capture and remove airborne smoke, dust, fumes, grit or other contaminants from welding and other industrial processes.
Our P-610 unit is designed for use with the smokeless welding torches and lighter duty applications for collection of dust and smoke at the source. Polluted air is drawn away and filtered through a 3-stage filtration system.
The P-612 industry benchmark air cleaning unit collects dust and smoke at the source. Polluted air is drawn away and filtered through a 3-stage filtration system. The dual powered fan system assures consistent and effective performance. The side selection of filter combinations allow the unit to be used in a variety of applications.
The P-614 is the same as the P-612 industry benchmark air cleaning unit, yet comes complete with the an "AUTO-START" control which turns on the collector when the welder strikes the arc.
All units come c/w the following standard filterVery lightweight extraction Hose 2" dia. (50mm), 8' long (2.5m) Heavy duty 14 ga. electrical cable and plug 15' (4.5M) All steel construction: Weight (28 Lbs 13kg) Compact design 650 x 250 x 450mm "Plug & Play" design: 110V/1/60Hz
Our P-610 unit is designed for use with the smokeless welding torches and lighter duty applications for collection of dust and smoke at the source. Polluted air is drawn away and filtered through a 3-stage filtration system.
The P-612 industry benchmark air cleaning unit collects dust and smoke at the source. Polluted air is drawn away and filtered through a 3-stage filtration system. The dual powered fan system assures consistent and effective performance. The side selection of filter combinations allow the unit to be used in a variety of applications.
The P-614 is the same as the P-612 industry benchmark air cleaning unit, yet comes complete with the an "AUTO-START" control which turns on the collector when the welder strikes the arc.
All units come c/w the following standard filter
Attachments
001 - Spec Drawings:
002 - Brochures:
004 - Videos:
014 - How It Goes Together:
017 - DWG and RVT models:
Buyer Guides:
(12-02) V1 - Weld Fume & Source Captured Dust - Washable and/or Disposable filters - (107 & 200 CFM)**
_V1_-_Weld_Fume_&_Source_Captured_Dust_-_Washable_andor_Disposable_filters_-_(107_&_200_CFM)_74/(12-02)_V1_-_Weld_Fume_&_Source_Captured_Dust_-_Washable_andor_Disposable_filters_-_(107_&_200_CFM).jpg)
200 CFM Portable high vacuum dust, smoke and fume collector w/high efficiency cleanable/disposable cartridge filter, 2 motor blowers, 115/1/60, 16 amps, 2/lighted on-off switch & 6’ power cord, cord wrap/handle & caster wheels.
Attachments
001 - Spec Drawings:
002 - Brochures:
004 - Videos:
017 - DWG and RVT models:
Buyer Guides:
(12-03) V2 - Weld Fume & Source Captured Dust - Self Cleaning filter system - (190 CFM) **
_V2_-_Weld_Fume_&_Source_Captured_Dust_-_Self_Cleaning_filter_system_-_(190_CFM)_48/(12-03)_V2_-_Weld_Fume_&_Source_Captured_Dust_-_Self_Cleaning_filter_system_-_(190_CFM).jpg)
Portable high vacuum cartridge collector, 2 Clean 2® filter cartridges 107 ft2 of media ea., Vibra-Pulse® cleaning system.Must order hose connector separately.
Attachments
001 - Spec Drawings:
002 - Brochures:
003 - Case Studies:
004 - Videos:
017 - DWG and RVT models:
Buyer Guides:
(12-04) V410 - Weld Fume & Source Captured Dust - Self Cleaning filter system - (300 & 500 CFM)**
_V410_-_Weld_Fume_&_Source_Captured_Dust_-_Self_Cleaning_filter_system_-_(300_&_500_CFM)_153/(12-04)_V410_-_Weld_Fume_&_Source_Captured_Dust_-_Self_Cleaning_filter_system_-_(300_&_500_CFM).jpg)
Portable high vacuum cartridge collector, (2) Clean 2® filter cartridges 150ft² each, factory pre-coated and include manual Vibra-Pulse® cleaning system. Must order hose connector separately.
Attachments
001 - Spec Drawings:
002 - Brochures:
004 - Videos:
017 - DWG and RVT models:
Buyer Guides:
Solutions forPortable Vehicle Exhaust Extraction
Portable Vehicle Exhaust Extraction
(13-04) Portable P-Max - Optional Hose, Nozzles... - (600 -1,500 CFM)
_Portable_P-Max_-_Optional_Hose_Nozzles_-_(600_-1500_CFM)_581/(13-04)_Portable_P-Max_-_Optional_Hose_Nozzles_-_(600_-1500_CFM).jpg)
P-Max© "Portable Local Exhaust" fans. Recommended for applications involving vehicle exhaust gases, welding fumes, smoke and light dust. An excellent portable solution where a fixed mounted system is not possible. These fans are designed specifically for "Medium Pressure" applications where the fan must be able to overcome the air resistance created when drawing contaminants through hoses.
Attachments
001 - Spec Drawings:
002 - Brochures:
017 - DWG and RVT models:
Solutions forExtraction Arms
Extraction Arms

(01-01) FLEXI - DUST, FUMES & GASES TO 17’ - INTERNALLY SUPPORTED - 6.5'' Ø (650 CFM) & 8'' Ø (1000 CFM)**
_FLEXI_-_DUST_FUMES_&_GASES_TO_17’_-_INTERNALLY_SUPPORTED_-_65''_Ø_(650_CFM)_&_8''_Ø_(1000_CF_829/(01-01)_FLEXI_-_DUST_FUMES_&_GASES_TO_17’_-_INTERNALLY_SUPPORTED_-_65''_Ø_(650_CFM)_&_8''_Ø_(1000_CF.jpg)
“Ready to install and use” FLEXI Extraction Arms are excellent solutions for capturing fumes and dust at source and exhausting to the atmosphere.Black steel hood Built in damper Flameproof double skin flexible hose Wall bracket "Stay in place" Extractor arm Optional components available such as: Exhaust Fan c/w motor overload, bird screen, backdraft damper, exhaust duct, wall flashing and extensions hoses and hoods are available.
Attachments
001 - Spec Drawings:
001a - Spec Drawing - Installation Examples:
- (01-01-10) How to join FLEXI+H-MAX+PXXX+PMAX+P023HMAX+PDK8+DUCT.pdf
- (01-01-11) How to join FLEXI+P-MAX-P-766+PDK-8.pdf
- (01-01-12) FLEXI+STANCHION+BMFAN+P766HD.pdf
- (01-01-13) FLEXI+STANCHION+LDFAN.pdf
- (01-01-14) How to join RELH160200+FLEXI + WFSC+PDK8SW.PDF
- (01-01-15) How to join FLEXI+DUALADAPTER+WFSC+SILENCER.pdf
- (01-01-01) How to join FLEXI+HMAX+PMAX+P766+SIL8+PDK.pdf
- (01-01-02) How to join FLEXI+PMAX+PDK8RF.pdf
- (01-01-03) How to join FLEXI+HMAX+P045+PMAX+PDK8.pdf
- (01-01-04) How to join FLEXI+HMAX+HERCULIAN+PXX+PMAX+PDK8.pdf
- (01-01-05) How to join FLEXI+HMAX+PXXX+PMAX+SIL8+PDK8.pdf
- (01-01-06) How to join FLEXI+P766XX+PMAX.pdf
- (01-01-07) How to join FLEXI+HMAX+HERCULIAN+PXX+PMAX+PDK8.SLDDRW.pdf
- (01-01-08) How to join FLEXI+HMAX+LDFAN.pdf
- (01-01-09) How to join FLEXI+HMAX+HERCULIAN+LDFAN.pdf
- (01-01-20) How to join FLEXI+HMAX+PXXX+PMAX+PDK8.pdf
002 - Brochures:
003 - Case Studies:
003a - Video Case Study:
004 - Videos:
007 - Written Specifications:
017 - DWG and RVT models:
Buyer Guides:
(01-02) E-Z ARM - Sparks & Abrasion to 14’ - Hybrid Support - 7'' Ø (900 CFM)* **
_E-Z_ARM_-_Sparks_&_Abrasion_to_14’_-_Hybrid_Support_-_7''_Ø_(900_CFM)_38/(01-02)_E-Z_ARM_-_Sparks_&_Abrasion_to_14’_-_Hybrid_Support_-_7''_Ø_(900_CFM).jpg)
The EZ-ARM High Flow Extractor is an excellent solution for most medium to high volume extraction applications. The arm comes complete with Airflow Systems' patented friction release pawl-and-sprocket design. This extraction arm engages positively when placed in its final position, yet offers no resistance when re-positioning is required. A large 13” Ø inlet hood with 360° flange handle allows simple positioning of the hood (versus single handle designs). This extractor comes in 3 lengths- 2m (7’), 3m (10’), 4m (14'), 6M (20'), 8M (26') - and 175mm (7”) diameter.
Attachments
001 - Spec Drawings:
003 - Case Studies:
006 - System Layouts:
007 - Written Specifications:
017 - DWG and RVT models:
(01-03) E-Z ARM II - Bench or Desk Top to 8’ - Hybrid Support - 4'' Ø (300 CFM)**
_E-Z_ARM_II_-_Bench_or_Desk_Top_to_8’_-_Hybrid_Support_-_4''_Ø_(300_CFM)_79/(01-03)_E-Z_ARM_II_-_Bench_or_Desk_Top_to_8’_-_Hybrid_Support_-_4''_Ø_(300_CFM).jpg)
4” Ø externally supported fume exhaust arms. Simple, effective and highly reliable devices used to remove smoke, fumes, dust and dirt away from the work area. Because the exhaust arms are easy to maneuver, they can command a large work area allowing coverage anywhere within the range of motion. This extractor comes in 2 lengths; 1.5m (5’), and 2.5m (8’). It can be extended up to 42' by adding the appropriate boom extensions. This combination allows for high-volume collection with maximum reach. A large 8” Ø inlet hood with 360° flange handle allow simple positioning of the hood (versus single handle designs).
Attachments
001 - Spec Drawings:
002 - Brochures:
004 - Videos:
017 - DWG and RVT models:
(01-04) E-Z Arm Jr. - Lab & Bench Top to 6’ - Externally Supported - 2.5'' Ø (150 CFM)**
_E-Z_Arm_Jr_-_Lab_&_Bench_Top_to_6’_-_Externally_Supported_-_25''_Ø_(150_CFM)_191/(01-04)_E-Z_Arm_Jr_-_Lab_&_Bench_Top_to_6’_-_Externally_Supported_-_25''_Ø_(150_CFM).jpg)
2.5" diameter high performance fume arm with external support joints. 3' or 5' long complete with angle cut nozzle. White tubes, hood and hose. (Does not include wall mounting bracket or motor/blower.)
Attachments
001 - Spec Drawings:
002 - Brochures:
003 - Case Studies:
004 - Videos:
006 - System Layouts:
007 - Written Specifications:
017 - DWG and RVT models:
(01-05) Pro-Flex - All Applications to 30’ - Externally Supported - Diameter & Flow to suit **
_Pro-Flex_-_All_Applications_to_30’_-_Externally_Supported_-_Diameter_&_Flow_to_suit_572/(01-05)_Pro-Flex_-_All_Applications_to_30’_-_Externally_Supported_-_Diameter_&_Flow_to_suit.jpg)
The externally supported PRO-FLEX Extraction Arm is a superior arm that comes complete with an advanced "parallelogram / counter balanced" design eliminating the need for continual adjustment of friction joints and allowing for unparalleled ease of use. The PRO-FLEX is an ideal solution for most "source-capture" applications. It is not just a stretched out extractor arm. Two ball-bearing mounted horizontal arms with disc-brakes give an excellent horizontal maneuverability. It is also specifically recommended for applications requiring an "easy to position" extractor that does not require constant adjustment.
Pro-Flex Extractor Crane is the optimal solution when you need to cover large work areas. It come in 28 different configurations:
Lengths: 3M (10') -- 4M (14') -- 5m (17’) -- 6m (20') -- 7m (23’) -- 8m (26’) -- 9 m (30’)
Diameters: 100mm (4”) -- 125mm (5”) -- 160mm (6.5”) -- 200mm (8”).
Pro-Flex Extractor Crane is the optimal solution when you need to cover large work areas. It come in 28 different configurations:
Attachments
001 - Spec Drawings:
001a - Spec Drawing - Installation Examples:
002 - Brochures:
003 - Case Studies:
006 - System Layouts:
017 - DWG and RVT models:
(01-06) Telescopic - Confined locations to 8’ - Hybrid Support - 4'' Ø (300 CFM) & 6'' Ø (600 CFM)**
_Telescopic_-_Confined_locations_to_8’_-_Hybrid_Support_-_4''_Ø_(300_CFM)_&_6''_Ø_(600_CFM)_465/(01-06)_Telescopic_-_Confined_locations_to_8’_-_Hybrid_Support_-_4''_Ø_(300_CFM)_&_6''_Ø_(600_CFM).jpg)
The Telescopic Arms are well suited for work stations located against a wall. There are no obstructions inside the hose, improving airflow through the arm and simplifying cleaning and maintenance. The Telescoping Arms are easily adjusted and have 360º rotation at the base joint. Very versatile and user friendly. Telescoping Arms are designed to connect to new or existing ductwork, boom arms, or directly to Airflow collection and filtration units and is fastener free in the air stream.
Attachments
001 - Spec Drawings:
002 - Brochures:
017 - DWG and RVT models:
(01-08) Super-Max - Stainless Steel Extraction Arms7' 10' 14’ - Externally Supported - 4'' Ø (300 CFM), 6.5'' Ø (650 CFM) & 8'' Ø (1000 CFM)**
_Super-Max_-_Stainless_Steel_Extraction_Arms7'_10'_14’_-_Externally_Supported_-_4''_Ø_(300_CF_43/(01-08)_Super-Max_-_Stainless_Steel_Extraction_Arms7'_10'_14’_-_Externally_Supported_-_4''_Ø_(300_CF.jpg)
Stainless Steel Extraction arms with wall bracket. Parallelogram design. Steel hood with combined universal- and spinning-joint. Flameproof PVC hose 120mm, 160mm, 200mm (5", 6.5”, 8") Ø* with internal steel spiral. Adapted for central or individual extraction fan.
Attachments
001 - Spec Drawings:
002 - Brochures:
003 - Case Studies:
004 - Videos:
006 - System Layouts:
017 - DWG and RVT models:
(01-09) H-MAX - Arm Extensions to 30’ - Externally Supported - 6.5'' Ø (650CFM) & 8'' Ø (1000 CFM)**
_H-MAX_-_Arm_Extensions_to_30’_-_Externally_Supported_-_65''_Ø_(650CFM)_&_8''_Ø_(1000_CFM)_567/(01-09)_H-MAX_-_Arm_Extensions_to_30’_-_Externally_Supported_-_65''_Ø_(650CFM)_&_8''_Ø_(1000_CFM).jpg)
The H-MAX Extension Boom is used to support single extraction arms in applications where you need to reach over long distances. The H-MAX Extension Boom has a ball bearing articulation in the wall bracket which enables a 180º movement.
Attachments
001 - Spec Drawings:
003 - Case Studies:
003a - Video Case Study:
006 - System Layouts:
017 - DWG and RVT models:
(01-10) HERCULIAN Arm Extensions to 44’ - Externally Supported - 6.5'' Ø (650 CFM) & 8'' Ø (1000 CFM)
_HERCULIAN_Arm_Extensions_to_44’_-_Externally_Supported_-_65''_Ø_(650_CFM)_&_8''_Ø_(1000_CFM)_446/(01-10)_HERCULIAN_Arm_Extensions_to_44’_-_Externally_Supported_-_65''_Ø_(650_CFM)_&_8''_Ø_(1000_CFM).jpg)
The HERCULIAN Articulating Extension Boom is designed to be used in applications where you need to reach over very long distances. The HERCULIAN Articulating Extension Boom can support any Pro-Flex Extraction Crane or H-MAX Articulating Extension Boom with a Flexi-I, Flexi-II or E-Z Arm at the end. The HERCULIAN Articulating Extension Boom has a ball bearing articulation in the wall bracket which enables a 180º movement.
Attachments
001 - Spec Drawings:
002 - Brochures:
006 - System Layouts:
(01-11) Accessories for Extraction Arms - Extension brackets, hoses, hood extensions…**
_Accessories_for_Extraction_Arms_-_Extension_brackets_hoses_hood_extensions…_578/(01-11)_Accessories_for_Extraction_Arms_-_Extension_brackets_hoses_hood_extensions….jpg)
Accessories for extraction arms such as:Magnetic Nozzles Hose extensions Extension Hoods Vehicle Exhaust accessories Etc. Products: Dual magnet holder bracket">Dual magnet holder bracket.
Attachments
001 - Spec Drawings:
001a - Spec Drawing - Installation Examples:
002 - Brochures:
003 - Case Studies:
004 - Videos:
Solutions forPortable Filter Units
Portable Filter Units

(02-01) Roll-Flex - Weld Fume, Dusts & Gases - 700 to 1,400 CFM - 6.5” Ø Extraction Arm* **
_Roll-Flex_-_Weld_Fume_Dusts_&_Gases_-_700_to_1400_CFM_-_65”_Ø_Extraction_Arm_826/(02-01)_Roll-Flex_-_Weld_Fume_Dusts_&_Gases_-_700_to_1400_CFM_-_65”_Ø_Extraction_Arm.jpg)
ROLL FLEX filter ideally suited for most welding fumes, grinding and non-explosive/flammable dust applications. This solution is compact, very flexible and comes complete with a 7’ or 10’ extraction arm. Best suited for the following applications:Training & Testing facilities & schools Light to Medium welding applications MRO-Maintenance repair & overhaul "Rework" applications.
Attachments
001 - Spec Drawings:
003 - Case Studies:
004 - Videos:
017 - DWG and RVT models:
Buyer Guides:
(02-02) PCH-1 - Heavy Dusts & Smoke - Self cleaning filter system built in - 800 to 1500 CFM - 7” Ø Extraction Arm* **
_PCH-1_-_Heavy_Dusts_&_Smoke_-_Self_cleaning_filter_system_built_in_-_800_to_1500_CFM_-_7”_Ø__542/(02-02)_PCH-1_-_Heavy_Dusts_&_Smoke_-_Self_cleaning_filter_system_built_in_-_800_to_1500_CFM_-_7”_Ø_.jpg)
Portable cartridge collector, ideal for medium and heavy-duty maintenance or production welding, grinding and most dust producing applications. It comes complete with 7' EZ-Arm® high flow extractor (with damper), (1) Clean2® filter cartridges (150ft² of media), manual VIBRA-PULSE® filter cleaning system, a 1.5 HP TEFC motor, backward incline blower, removable 5 gallon external dust drawer, 8” front wheels, and 5” rear swivel casters.
Attachments
001 - Spec Drawings:
002 - Brochures:
004 - Videos:
017 - DWG and RVT models:
(02-03) PCH-2 - Heavy Dusts & Smoke - Self cleaning filter system built in - 1000 to 2200 CFM - 7” Ø Extraction Arm* **
_PCH-2_-_Heavy_Dusts_&_Smoke_-_Self_cleaning_filter_system_built_in_-_1000_to_2200_CFM_-_7”_Ø_543/(02-03)_PCH-2_-_Heavy_Dusts_&_Smoke_-_Self_cleaning_filter_system_built_in_-_1000_to_2200_CFM_-_7”_Ø.jpg)
The PCH-2 is a portable cartridge collector, ideal for medium and heavy-duty welding, grinding, cutting and other heavy dust producing applications. Rolled into position with the aid of 2 - large 8” diameter front wheels and 2 - 5” diameter locking rear casters, the PCH-2 easily navigates common obstacles found on the shop floor such as air hoses, extension cords, etc. The 2 foot wide “Push” handle, doubles nicely as a “Cord Caddy” for the 12Ga, 25’, safety yellow extension cord that comes standard with all 115/1/60 models. The HEAVY DUTY extraction arm is easily placed above or next to the emission source, hovering in place, allowing the fumes to be extracted at source before they contaminate they work environment or enter the operators breathing zone. Coming standard with a 10' EZ-Arm® high flow extractor (with damper), this unit is upgradeable to 14’ or 17’, single or dual extraction arms. (2) Clean2® high efficiency filter cartridges, clean the contaminated air to an efficiency level above 99.5% while allowing for optional HEPA or gas phase filters to be installed as required. Main filters can be cleaned in place, without removal, by simply activating the VIBRA-PULSE® filter cleaning system, a simple reverse pulse cleaning mechanism that cleans the filters with compressed air from the inside out. The dust is then easily removed from a cam-lock sealed drawer. Comes standard with a 115V/1/60 1.5 HP 1000 CFM fan, the PCH-2 can also be ordered with a 1200 CFM 3HP, or 1500 CFM 5HP, 230-460/575V/3/60Hz Fan. All units come complete with EPact Baldor Super E, Premium efficiency motors and carry a complete system warranty of 3 years.
Attachments
001 - Spec Drawings:
002 - Brochures:
003 - Case Studies:
017 - DWG and RVT models:
(02-04) Mobi-Pulse 1 (700 to 1400 CFM) **
_Mobi-Pulse_1_(700_to_1400_CFM)_639/(02-04)_Mobi-Pulse_1_(700_to_1400_CFM).jpg)
The Mobi-Pulse 1 is portable cartridge collector with a capacity up to 800 CFM. This unit is ideal for medium and heavy-duty maintenance or Low to Medium production welding, grinding and most dust producing applications. The standard Unit comes complete with (1) only 10' Flexi-I Extraction arm (6" dia.) with damper, (1) only Clean2® filter cartridge (150ft² of media), manual JET PULSE filter cleaning system, a 1 HP 115V/1/60 TEFC motor, centrifugal blower, removable 5 gallon dust drawer, 5” front (fixed) & rear (swivel) casters.
Attachments
001 - Spec Drawings:
002 - Brochures:
Buyer Guides:
(02-05) Mobi-Pulse 2 (800 to 2200 CFM) **
_Mobi-Pulse_2_(800_to_2200_CFM)_640/(02-05)_Mobi-Pulse_2_(800_to_2200_CFM).jpg)
The Mobi-Pulse 2 is a 800 to 1500 CFM portable cartridge collector, ideal for medium and heavy-duty maintenance or production welding, grinding and most dust producing applications. It comes complete with 10' Flexi II Extractor Arm (8" dia.) with damper, (2) Clean2® filter cartridges (150ft² of media each), manual VIBRA-PULSE® filter cleaning system, TEFC motor, removable 10 gallon external dust drawer, 8” front wheels, and 5” rear swivel casters.
Attachments
001 - Spec Drawings:
002 - Brochures:
Buyer Guides:
(02-06) PAC91 - Flammable Gases & Volatile Organic Compounds - 800 to 1,600 CFM - 7” Ø Extraction Arm **
_PAC91_-_Flammable_Gases_&_Volatile_Organic_Compounds_-_800_to_1600_CFM_-_7”_Ø_Extraction_Arm_147/(02-06)_PAC91_-_Flammable_Gases_&_Volatile_Organic_Compounds_-_800_to_1600_CFM_-_7”_Ø_Extraction_Arm.jpg)
Portable air cleaner with extraction arm to capture dust, mist, odours and gases right at the source. The patented self-supporting, flexible pickup hose can be easily positioned in all three axes, allowing complete capture to help comply with OSHA (when properly used and maintained) and insurance regulations. Applications include: coolant mist, carbon dust, plastic smoke, grinding dust, sanding dust, welding smoke, lint, fibers, and fumes.
Attachments
001 - Spec Drawings:
002 - Brochures:
004 - Videos:
014 - How It Goes Together:
017 - DWG and RVT models:
(02-07) MiniPac - Flammable Gases & Volatile Organic Compounds - 650 to 1000 CFM - 7” Ø Extraction Arm **
_MiniPac_-_Flammable_Gases_&_Volatile_Organic_Compounds_-_650_to_1000_CFM_-_7”_Ø_Extraction_A_25/(02-07)_MiniPac_-_Flammable_Gases_&_Volatile_Organic_Compounds_-_650_to_1000_CFM_-_7”_Ø_Extraction_A.jpg)
Portable air cleaner with (1) 7’ long E-Z Arm® high flow extractor (1) 2” aluminum mesh pre-filter, (1) 95% bag filter (28ft² of media), a ¾ HP TEFC motor, 115/230/1/60Hz (9.8/4.9 amps), and 5” casters, (2) fixed and (2) swivel with brakes.
Attachments
001 - Spec Drawings:
002 - Brochures:
004 - Videos:
017 - DWG and RVT models:
(02-08) MiniVac - Multipurpose Low flow - 150 to 300 CFM - 2.5” Ø Extraction Arm **
_MiniVac_-_Multipurpose_Low_flow_-_150_to_300_CFM_-_25”_Ø_Extraction_Arm_127/(02-08)_MiniVac_-_Multipurpose_Low_flow_-_150_to_300_CFM_-_25”_Ø_Extraction_Arm.jpg)
MiniVac portable air cleaner is designed for source extraction and filtration of dust and smoke. These small air cleaners are ideal when combined with self-supported extraction arm(s) or for ducted "Source-capture" applications.
Airflow: 120 CFM - single arm 210 CFM - dual arms (105 CFM/arm) 250 CFM - three arms (80 CFM/arm) 300 CFM@ 1.5" w.g. (no arms)
Airflow:
Attachments
001 - Spec Drawings:
002 - Brochures:
003 - Case Studies:
003a - Video Case Study:
004 - Videos:
007 - Written Specifications:
017 - DWG and RVT models:
(02-09) Mini Flex - (12''L x 13''W x 20''H, 2xØ3 inlet @ 100 CFM) **
_Mini_Flex_-_(12''L_x_13''W_x_20''H_2xØ3_inlet_@_100_CFM)_669/(02-09)_Mini_Flex_-_(12''L_x_13''W_x_20''H_2xØ3_inlet_@_100_CFM).png)
Soldering Fume Collector with a (1) 1" Poly Filter, (1) 99.97% HEPA filter, 1" charcoal filter, a 200 Watt motor, 115/1/60Hz (0.85 amps), and Aluminum Hood and 2 - 3" x 42" long hose.
Attachments
001 - Spec Drawings:
002 - Brochures:
(02-12) MicroAir Systems Portable UNIT MC-1500**
_MicroAir_Systems_Portable_UNIT_MC-1500_707/(02-12)_MicroAir_Systems_Portable_UNIT_MC-1500.jpg)
When selecting a system for weld fume and smoke, there are many contributing factors to
provide equipment that meets all of your needs. Micro Air can design the system to your unique
filtration efficiencies, floor space utilization, worker mobility and portability, and budget, all
while meeting OSHA and NIOSH standards. By using our high efficiency cartridge or HEPA units,
we can eliminate the need for costly make-up air by filtering and exhausting the air back into
your facility.
provide equipment that meets all of your needs. Micro Air can design the system to your unique
filtration efficiencies, floor space utilization, worker mobility and portability, and budget, all
while meeting OSHA and NIOSH standards. By using our high efficiency cartridge or HEPA units,
we can eliminate the need for costly make-up air by filtering and exhausting the air back into
your facility.
Attachments
002 - Brochures:
(02-13) SCC Series- Trolley-mounted vacuum filter for wood dusts and shavings **
_SCC_Series-_Trolley-mounted_vacuum_filter_for_wood_dusts_and_shavings_911/(02-13)_SCC_Series-_Trolley-mounted_vacuum_filter_for_wood_dusts_and_shavings.png)
Trolley-mounted vacuum filter for wood dusts and shavings. Due to their heavy use in the industrial environment, the SCC series dust collectors are very strong and solid; this guarantees longer duration through time. Moreover, thanks to accurate design, they are reliable and user friendly. SCC series is suitable for the extraction of dusts of a various nature and dry shavings on individual or multiple sources of dust.
(02-14) Dustflex- Down flow wheeled filter for welding fumes, fine and coarse dusts as well as of small quantities of chips **
_Dustflex-_Down_flow_wheeled_filter_for_welding_fumes_fine_and_coarse_dusts_as_well_as_of_sma_922/(02-14)_Dustflex-_Down_flow_wheeled_filter_for_welding_fumes_fine_and_coarse_dusts_as_well_as_of_sma.jpg)
The Dustflex DF are filter units equipped with horizontal cartridges suitable for suction and filtration of welding fumes, fine and coarse dusts as well as of small quantities of chips.
They are composed by powder coated steel panels and prefitted with articulated arm flanged connection model UNIVERSAL NO-SMOKE 3.3 mts (Standard) or EVOLUTION NO–SMOKE 3 mts (Optional) both in Dia 6" (150 mm). They are engineered to be used inside the work premises.
The polluted air is sucked through the inlet thanks to the depression created by the suction fan positioned on the clean side.
The filter unit consists of one vertical pre-chamber, where the heaviest dusts are sorted out, falling then in a first collecting bin. The following labyrinth together with the high efficiency filtering cartridges complete the filtration of the remaining fine dusts collected in the second bin.
The high performance fan, placed just on the top of the unit, assures a high suction capacity and a low noise level, the clean air is exhausted out through a top grill.
The JETCLEAN DF thanks to the pneumatic cleaning automatic system (with compressed air) grants the perfect efficiency of the filter cartridges.
The CLEANING DF unit is equipped instead with disposable filter
cartridges.
They are composed by powder coated steel panels and prefitted with articulated arm flanged connection model UNIVERSAL NO-SMOKE 3.3 mts (Standard) or EVOLUTION NO–SMOKE 3 mts (Optional) both in Dia 6" (150 mm). They are engineered to be used inside the work premises.
The polluted air is sucked through the inlet thanks to the depression created by the suction fan positioned on the clean side.
The filter unit consists of one vertical pre-chamber, where the heaviest dusts are sorted out, falling then in a first collecting bin. The following labyrinth together with the high efficiency filtering cartridges complete the filtration of the remaining fine dusts collected in the second bin.
The high performance fan, placed just on the top of the unit, assures a high suction capacity and a low noise level, the clean air is exhausted out through a top grill.
The JETCLEAN DF thanks to the pneumatic cleaning automatic system (with compressed air) grants the perfect efficiency of the filter cartridges.
The CLEANING DF unit is equipped instead with disposable filter
cartridges.
(02-23) Roll-Flex-V - 700 to 1,400 CFM - VOC's and Odours - c/w 6.5 Extraction Arm **
_Roll-Flex-V_-_700_to_1400_CFM_-_VOC's_and_Odours_-_cw_65_Extraction_Arm_839/(02-23)_Roll-Flex-V_-_700_to_1400_CFM_-_VOC's_and_Odours_-_cw_65_Extraction_Arm.jpg)
This "V" version of the ROLL FLEX filter is ideally suited for most VOC, ODOUR, and SMALL SPRAY painting applications.
The air is pre-filtered with a washable particulate filter and then then treated by either a single or dual stage, "gas phase" adsorption media filter. This solution is compact, very flexible and comes complete with a 7’ or 10' extraction arm.
The air is pre-filtered with a washable particulate filter and then then treated by either a single or dual stage, "gas phase" adsorption media filter. This solution is compact, very flexible and comes complete with a 7’ or 10' extraction arm.
Attachments
001 - Spec Drawings:
(02-99) SE1400 Smoke Extractor **
_SE1400_Smoke_Extractor_686/(02-99)_SE1400_Smoke_Extractor.jpg)
Portable Filtration of Dust and Gases c/w 2 Stage filtration (Spark arresting Pre-filter & Washable Main filter), Fan & Super flexible Extraction Arm. Capacity of 1450 CFM ''Free-Blowing' and 700 CFM ''at the Hood''
The SE1400 smoke extractor provides both high volume extraction and a high degree of filtration - up to 99.9% efficiency. The extraction arm captures welding fume and dust at a distance of 12 - 20" (30 - 50 cm) from the source and within an area of 20" (0.5 m) diameter. The arm can be rotated through 360 degrees. The unit can also be fitted with an activated charcoal filter which removes gases from polluted air. Also available with a HEPA filter.
Available EXCLUSIVELY at all RED-D-ARC Locations in North America
The SE1400 smoke extractor provides both high volume extraction and a high degree of filtration - up to 99.9% efficiency. The extraction arm captures welding fume and dust at a distance of 12 - 20" (30 - 50 cm) from the source and within an area of 20" (0.5 m) diameter. The arm can be rotated through 360 degrees. The unit can also be fitted with an activated charcoal filter which removes gases from polluted air. Also available with a HEPA filter.
Available EXCLUSIVELY at all RED-D-ARC Locations in North America
Attachments
001 - Spec Drawings:
002 - Brochures:
(12-01) Porta-Flex - Weld Fume - Washable and/or Disposable Filters - (125 & 250 CFM)
_Porta-Flex_-_Weld_Fume_-_Washable_andor_Disposable_Filters_-_(125_&_250_CFM)_507/(12-01)_Porta-Flex_-_Weld_Fume_-_Washable_andor_Disposable_Filters_-_(125_&_250_CFM).jpg)
At 28 lbs., these light weight units will go anywhere. Designed for use in confined spaces and areas where portability is a must. The one-man portable unit quickly removes harmful airborne smoke and particulate from the breathing and work zone through the 8' flexible hose and optional positioning arm and nozzles with magnetic base. The large selection of filter combinations allow these units to effectively capture and remove airborne smoke, dust, fumes, grit or other contaminants from welding and other industrial processes.
Our P-610 unit is designed for use with the smokeless welding torches and lighter duty applications for collection of dust and smoke at the source. Polluted air is drawn away and filtered through a 3-stage filtration system.
The P-612 industry benchmark air cleaning unit collects dust and smoke at the source. Polluted air is drawn away and filtered through a 3-stage filtration system. The dual powered fan system assures consistent and effective performance. The side selection of filter combinations allow the unit to be used in a variety of applications.
The P-614 is the same as the P-612 industry benchmark air cleaning unit, yet comes complete with the an "AUTO-START" control which turns on the collector when the welder strikes the arc.
All units come c/w the following standard filterVery lightweight extraction Hose 2" dia. (50mm), 8' long (2.5m) Heavy duty 14 ga. electrical cable and plug 15' (4.5M) All steel construction: Weight (28 Lbs 13kg) Compact design 650 x 250 x 450mm "Plug & Play" design: 110V/1/60Hz
Our P-610 unit is designed for use with the smokeless welding torches and lighter duty applications for collection of dust and smoke at the source. Polluted air is drawn away and filtered through a 3-stage filtration system.
The P-612 industry benchmark air cleaning unit collects dust and smoke at the source. Polluted air is drawn away and filtered through a 3-stage filtration system. The dual powered fan system assures consistent and effective performance. The side selection of filter combinations allow the unit to be used in a variety of applications.
The P-614 is the same as the P-612 industry benchmark air cleaning unit, yet comes complete with the an "AUTO-START" control which turns on the collector when the welder strikes the arc.
All units come c/w the following standard filter
Attachments
001 - Spec Drawings:
002 - Brochures:
004 - Videos:
014 - How It Goes Together:
017 - DWG and RVT models:
Buyer Guides:
(12-02) V1 - Weld Fume & Source Captured Dust - Washable and/or Disposable filters - (107 & 200 CFM)**
_V1_-_Weld_Fume_&_Source_Captured_Dust_-_Washable_andor_Disposable_filters_-_(107_&_200_CFM)_74/(12-02)_V1_-_Weld_Fume_&_Source_Captured_Dust_-_Washable_andor_Disposable_filters_-_(107_&_200_CFM).jpg)
200 CFM Portable high vacuum dust, smoke and fume collector w/high efficiency cleanable/disposable cartridge filter, 2 motor blowers, 115/1/60, 16 amps, 2/lighted on-off switch & 6’ power cord, cord wrap/handle & caster wheels.
Attachments
001 - Spec Drawings:
002 - Brochures:
004 - Videos:
017 - DWG and RVT models:
Buyer Guides:
(12-03) V2 - Weld Fume & Source Captured Dust - Self Cleaning filter system - (190 CFM) **
_V2_-_Weld_Fume_&_Source_Captured_Dust_-_Self_Cleaning_filter_system_-_(190_CFM)_48/(12-03)_V2_-_Weld_Fume_&_Source_Captured_Dust_-_Self_Cleaning_filter_system_-_(190_CFM).jpg)
Portable high vacuum cartridge collector, 2 Clean 2® filter cartridges 107 ft2 of media ea., Vibra-Pulse® cleaning system.Must order hose connector separately.
Attachments
001 - Spec Drawings:
002 - Brochures:
003 - Case Studies:
004 - Videos:
017 - DWG and RVT models:
Buyer Guides:
(12-04) V410 - Weld Fume & Source Captured Dust - Self Cleaning filter system - (300 & 500 CFM)**
_V410_-_Weld_Fume_&_Source_Captured_Dust_-_Self_Cleaning_filter_system_-_(300_&_500_CFM)_153/(12-04)_V410_-_Weld_Fume_&_Source_Captured_Dust_-_Self_Cleaning_filter_system_-_(300_&_500_CFM).jpg)
Portable high vacuum cartridge collector, (2) Clean 2® filter cartridges 150ft² each, factory pre-coated and include manual Vibra-Pulse® cleaning system. Must order hose connector separately.
Attachments
001 - Spec Drawings:
002 - Brochures:
004 - Videos:
017 - DWG and RVT models:
Buyer Guides:
Solutions forSingle or Dual Work-Station Filter Units
Single or Dual Work-Station Filter Units

(03-01) DCH-1 - Heavy Duty Dusts & Smoke - Self cleaning filter system built in - 300 to 800 CFM - 6” Ø inlet **
_DCH-1_-_Heavy_Duty_Dusts_&_Smoke_-_Self_cleaning_filter_system_built_in_-_300_to_800_CFM_-_6_174/(03-01)_DCH-1_-_Heavy_Duty_Dusts_&_Smoke_-_Self_cleaning_filter_system_built_in_-_300_to_800_CFM_-_6.jpg)
Cartridge collector with (1) Clean 2® cartridge filter (150ft² of media each), manual VIBRA-PULSE® filter cleaning system, and 6" collar on top. Includes either a 5 gallon external dust drawer or 10 gallon pail and hopper.
Attachments
001 - Spec Drawings:
002 - Brochures:
003 - Case Studies:
004 - Videos:
006 - System Layouts:
017 - DWG and RVT models:
(03-03) DCH-2 - Heavy Duty Dusts & Smoke - Self cleaning filter system built in - 600 to 1,200 CFM - 8” Ø inlet **
_DCH-2_-_Heavy_Duty_Dusts_&_Smoke_-_Self_cleaning_filter_system_built_in_-_600_to_1200_CFM_-__31/(03-03)_DCH-2_-_Heavy_Duty_Dusts_&_Smoke_-_Self_cleaning_filter_system_built_in_-_600_to_1200_CFM_-_.jpg)
Cartridge dust collector with (2) Clean 2® cartridge filter (150ft² of media each), manual VIBRA-PULSE® filter cleaning system, and 8" collar on top. Includes a 10 gallon external dust drawer or tray.
Attachments
0001 - Installation Examples - How products go together:
001 - Spec Drawings:
002 - Brochures:
003 - Case Studies:
003a - Video Case Study:
004 - Videos:
006 - System Layouts:
017 - DWG and RVT models:
(03-05) WF - Weld Fume, Dusts & Gases - Cleanable filters - 300 to 1400 CFM - 6” Ø inlet **
_WF_-_Weld_Fume_Dusts_&_Gases_-_Cleanable_filters_-_300_to_1400_CFM_-_6”_Ø_inlet_574/(03-05)_WF_-_Weld_Fume_Dusts_&_Gases_-_Cleanable_filters_-_300_to_1400_CFM_-_6”_Ø_inlet.jpg)
Wall-mounted mechanical filter unit c/w direct mount P-Max fan. The unit comes standard with either a spun-bound polyester (washable) filter. Designed for use with extraction arms, and/or ducted applications.
Attachments
001 - Spec Drawings:
001a - Spec Drawing - Installation Examples:
002 - Brochures:
003 - Case Studies:
004 - Videos:
006 - System Layouts:
017 - DWG and RVT models:
Buyer Guides:
(03-07) SSWC - Wet Collector Explosive Dusts - Self cleaning/draining filter system built in - 1200 to 5,500 CFM**
_SSWC_-_Wet_Collector_Explosive_Dusts_-_Self_cleaningdraining_filter_system_built_in_-_1200_t_597/(03-07)_SSWC_-_Wet_Collector_Explosive_Dusts_-_Self_cleaningdraining_filter_system_built_in_-_1200_t.jpg)
The Stainless Steel Wet Dust Collection System from LEV-CO comes in a variety of models that are intended for safe, efficient collection of various dusts from sanding, grinding and deburring operations. Dust particles sink to the base of the tank and are easily racked into a disposal container using.
1. Dust suitable for wet collection includes:Quick wetting and sinking dust Materials of a combustible nature Applications where sparks may occur Applications where mixing of material and various minerals occur Other special applications.
2. Standard features No filter bags/Low maintenance Stainless steel construction Water level controller 1 Micron solid/liquid phase after filter Sound silencer Magnetic starter, prewired with main disconnect T.E.F.C. motors Small particle grids for higher efficiency Models 1200 CFM to 5500 CFM
3. Optional equipment Explosion-proof motors HEPA and Carbon filters Custom ductwork kits Single and Dual Extraction arms (6.5” to 12” diameter – 7’ to 17’ long) Portable option (Wheel kits) Custom direct mount Downdraft tables Water level controller
1. Dust suitable for wet collection includes:
2. Standard features
3. Optional equipment
Attachments
001 - Spec Drawings:
002 - Brochures:
017 - DWG and RVT models:
Solutions forCentrally Ducted Filter Units
Centrally Ducted Filter Units

(04-01) L Series Vertically oriented cartridges Dust & Fume Collectors - Self cleaning filter system built in - 1,200 to 25,000 CFM **
_L_Series_Vertically_oriented_cartridges_Dust_&_Fume_Collectors_-_Self_cleaning_filter_system_546/(04-01)_L_Series_Vertically_oriented_cartridges_Dust_&_Fume_Collectors_-_Self_cleaning_filter_system.jpg)
Our line of vertical cartridges dust collectors offer extremely efficient and economical systems due to the continuous venturi assisted reverse pulse jet cleaning system. The system allows on-line cleaning, without significant loading thus maintaining constant internal static pressure levels. This system is designed to handle 20" w.g. of external static pressure.
Attachments
001 - Spec Drawings:
002 - Brochures:
003 - Case Studies:
006 - System Layouts:
007 - Written Specifications:
017 - DWG and RVT models:
(04-02) DC-4 Horizontally oriented cartridges Fume & Dust Collector - Self cleaning filter system built in - 1,000 to 2,400 CFM **
_DC-4_Horizontally_oriented_cartridges_Fume_&_Dust_Collector_-_Self_cleaning_filter_system_bu_185/(04-02)_DC-4_Horizontally_oriented_cartridges_Fume_&_Dust_Collector_-_Self_cleaning_filter_system_bu.jpg)
Cartridge dust collector w/(4) Clean 2® filters, front load, 3 HP motor/blower with AMCA Type B spark resistant aluminum blower wheel, 4.25 ft3, 11” deep removable dust pan, and auto-clean Vibra-Pulse® cleaning system, with ½” regulator. These collectors are ideal for most dust and smoke applications and they are especially recommended for harsh applications such as Laser & Plasma cutting or "Oily" weld smoke applications.
Attachments
001 - Spec Drawings:
002 - Brochures:
004 - Videos:
006 - System Layouts:
017 - DWG and RVT models:
(04-03) DC-6 Horizontally oriented cartridges Fume & Dust Collector - Self cleaning filter system built in - 1,500 to 3,600 CFM **
_DC-6_Horizontally_oriented_cartridges_Fume_&_Dust_Collector_-_Self_cleaning_filter_system_bu_17/(04-03)_DC-6_Horizontally_oriented_cartridges_Fume_&_Dust_Collector_-_Self_cleaning_filter_system_bu.jpg)
Cartridge dust collector w/(6) Clean 2® filters, front load, 3 HP motor/blower with AMCA Type B spark resistant aluminum blower wheel, 4.25 ft3, 11” deep removable dust pan, & auto-clean Vibra-Pulse® cleaning system with ½” regulator. These collectors are ideal for most dust and smoke applications and they are especially recommended for harsh applications such as Laser & Plasma cutting or "Oily" weld smoke applications.
Attachments
001 - Spec Drawings:
002 - Brochures:
003 - Case Studies:
004 - Videos:
007 - Written Specifications:
017 - DWG and RVT models:
(04-04) DC-8 Horizontally oriented cartridges Fume & Dust Collector - Self cleaning filter system built in - 2,000 to 4,800 CFM **
_DC-8_Horizontally_oriented_cartridges_Fume_&_Dust_Collector_-_Self_cleaning_filter_system_bu_73/(04-04)_DC-8_Horizontally_oriented_cartridges_Fume_&_Dust_Collector_-_Self_cleaning_filter_system_bu.jpg)
Cartridge dust collector with (8) Clean 2® filters, front load, 5 HP motor/blower with AMCA Type B spark resistant aluminum blower wheel, and auto clean Vibra-Pulse® cleaning system with ½” regulator. Motor starters not included These collectors are ideal for most dust and smoke applications and they are especially recommended for harsh applications such as Laser & Plasma cutting or "Oily" weld smoke applications.
Attachments
001 - Spec Drawings:
002 - Brochures:
004 - Videos:
017 - DWG and RVT models:
(04-05) DC-12 Horizontally oriented cartridges Fume & Dust Collector - Self cleaning filter system built in - 3,000 to 7,200 CFM**
_DC-12_Horizontally_oriented_cartridges_Fume_&_Dust_Collector_-_Self_cleaning_filter_system_b_56/(04-05)_DC-12_Horizontally_oriented_cartridges_Fume_&_Dust_Collector_-_Self_cleaning_filter_system_b.jpg)
Cartridge dust collector with (12) Clean 2® filters, front loading, 5 HP motor/blower with AMCA Type B spark resistant blower wheel, and auto clean Vibra-Pulse® cleaning system with ½” regulator. Motor starters not included. These collectors are ideal for most dust and smoke applications and they are especially recommended for harsh applications such as Laser & Plasma cutting or "Oily" weld smoke applications.
Attachments
001 - Spec Drawings:
002 - Brochures:
004 - Videos:
017 - DWG and RVT models:
(04-06) DC-18 Horizontally oriented cartridges Fume & Dust Collector - Self cleaning filter system built in - 4,500 to 10,800 CFM **
_DC-18_Horizontally_oriented_cartridges_Fume_&_Dust_Collector_-_Self_cleaning_filter_system_b_418/(04-06)_DC-18_Horizontally_oriented_cartridges_Fume_&_Dust_Collector_-_Self_cleaning_filter_system_b.jpg)
Cartridge dust collector with (18) Clean 2® filters, 5 HP motor/blower and block-off Vibra-Pulse® filter cleaning. Motor starters/disconnects not included. These collectors are ideal for most dust and smoke applications and they are especially recommended for harsh applications such as Laser & Plasma cutting or "Oily" weld smoke applications.
This unit has been designed to be placed outside including having the top panels angled to shed water. An access panel has been added to both sides of the clean air plenum to allow for easier maintenance on the block-off components, if needed. The cabinet also has a modular design to support multiple module units (DC-36, DC-54, etc.)
This unit has been designed to be placed outside including having the top panels angled to shed water. An access panel has been added to both sides of the clean air plenum to allow for easier maintenance on the block-off components, if needed. The cabinet also has a modular design to support multiple module units (DC-36, DC-54, etc.)
Attachments
001 - Spec Drawings:
002 - Brochures:
006 - System Layouts:
017 - DWG and RVT models:
(04-07) HWF Wet Collector - Explosive Dusts - Self cleaning filter system built in - 1,000 to 15,000 CFM **
_HWF_Wet_Collector_-_Explosive_Dusts_-_Self_cleaning_filter_system_built_in_-_1000_to_15000_C_211/(04-07)_HWF_Wet_Collector_-_Explosive_Dusts_-_Self_cleaning_filter_system_built_in_-_1000_to_15000_C.jpg)
HYDROTRON Water Filter Dust Collectors purify air by a combination of centrifugal force and violent mixing of water and contaminated air. As the air stream passes the fixed baffles, particulate is separated by heavy, turbulent curtain of water created by high velocity air. The centrifugal force caused by the rapid changes in airflow direction forces the dust particles to penetrate the water droplets and become entrapped. Contaminated water is then removed from the airstream by special mist filters. Dust, as sludge, settles to the collector bottom and the water is reused.
The HYDROTRON is specifically designed for safe collection of potentially explosive and volatile materials and is effective in the capture of fine metal particles. It meets the National Fire Protection Association guidelines for processing and finishing aluminum. Since the Hydrotron also meets OSHA and NFPA regulations for dust removal located inside buildings, it can recirculate in-plant, tempered air to conserve energy.
The HYDROTRON is specifically designed for safe collection of potentially explosive and volatile materials and is effective in the capture of fine metal particles. It meets the National Fire Protection Association guidelines for processing and finishing aluminum. Since the Hydrotron also meets OSHA and NFPA regulations for dust removal located inside buildings, it can recirculate in-plant, tempered air to conserve energy.
Attachments
001 - Spec Drawings:
002 - Brochures:
003 - Case Studies:
004 - Videos:
006 - System Layouts:
007 - Written Specifications:
017 - DWG and RVT models:
(04-12) LEV-SCS Series Bag Housing Collectors **
_LEV-SCS_Series_Bag_Housing_Collectors_714/(04-12)_LEV-SCS_Series_Bag_Housing_Collectors.jpg)
The dust is drawn into the dust collector, where the velocity of the dust is reduced. The heaviest particles fall directly into the hopper, while the finest particles are drawn into the interior surface of the bags.
The air coming through the bag is now clean, and can be recirculated within the plant or discharged outside.
The air coming through the bag is now clean, and can be recirculated within the plant or discharged outside.
Attachments
001 - Spec Drawings:
002 - Brochures:
003 - Case Studies:
003a - Video Case Study:
(04-13) Hyperjet Horizontal Cartridge Filters**
_Hyperjet_Horizontal_Cartridge_Filters_910/(04-13)_Hyperjet_Horizontal_Cartridge_Filters.png)
Industrial Duty dust collector best suited for heavy-duty applications such as Plasma Cutting, Arc-Air Gouging, Welding, grinding and many other. The unit comes equipped with Spark Trap, Pre-separator, Water filter, 2 cam-lock dust drawers with wheels and filter cleaning controls.
PLEASE NOTE: motor kit is selected to your horsepower and voltage requirements and must be ordered separately.
(04-26) AN100 Spark Detection system**
_AN100_Spark_Detection_system_721/(04-26)_AN100_Spark_Detection_system.jpg)
Complete spark detection system
Attachments
001 - Spec Drawings:
002 - Brochures:
(13-13) VFD System with Manual Dampers and Pressure Transmitter - Type 2**
_VFD_System_with_Manual_Dampers_and_Pressure_Transmitter_-_Type_2_870/(13-13)_VFD_System_with_Manual_Dampers_and_Pressure_Transmitter_-_Type_2.jpg)
Lev-co’s LEVEL 2 VFD system allows for “On-Demand” flow control of an exhaust fan for industrial ventilation applications.
FUNCTION:The fan is first activated by an "Optional" switch attached to the damper, hose reel, hose drop, current sensor*, etc. When this switch closes the fan turns on. Once the damper in the 1st drop opens, a digital pressure transmitter senses the pressure in the main duct downstream of the fan and allows the VFD to actively control motor speed as a function of duct (negative) pressure. As more dampers are opened and closed the fan speed increases and decreases in order to provide the required flowrate at each drop. This permits constant, effective exhaust at a target duct pressure no matter how many dampers are open or closed. Flow "On Demand" The fan turns off when the last operator has no more demand
The following components are included in this “Level 2” VFD solution: VFD (Variable Frequency Drive)IP65 Control Panel IP65 c/w with the following components: HOA Hand/Off/Auto selector switch ”Fan on” Pilot Light Pressure Transmitter 4-20 ma Digital Pressure Gauge 1-10” WG 100’ of pneumatic tubing 1/8” MPT hose barb (for connection to duct)
FUNCTION:
The following components are included in this “Level 2” VFD solution:
Attachments
001 - Spec Drawings:
002 - Brochures:
007 - Written Specifications:
Solutions forDown Draft Tables
Down Draft Tables

(05-01) EZ Bench - Light dusts - Washable and/or disposable filters - 36''W X 24''D (800 CFM)**
_EZ_Bench_-_Light_dusts_-_Washable_andor_disposable_filters_-_36''W_X_24''D_(800_CFM)_596/(05-01)_EZ_Bench_-_Light_dusts_-_Washable_andor_disposable_filters_-_36''W_X_24''D_(800_CFM).jpg)
Easy Bench – A 800 CFM (500 CFM with HEPA or AD Module)downdraft table designed for the operator. Standard desk height with full leg room for maximum comfort and concentration. Simple Source Capture. Removes dust, fumes, and odors, for a cleaner, healthier work environment, and
improved productivity for close, fine hand work. Easy Filter Access. Standard panels slide in and out from the front, with easy-seal magnetic covers.
improved productivity for close, fine hand work. Easy Filter Access. Standard panels slide in and out from the front, with easy-seal magnetic covers.
Attachments
001 - Spec Drawings:
002 - Brochures:
017 - DWG and RVT models:
(05-03) DTH800 - Heavy dusts & smoke - Self cleaning filter system built in - 24''D X 32’’W (800 CFM)* **
_DTH800_-_Heavy_dusts_&_smoke_-_Self_cleaning_filter_system_built_in_-_24''D_X_32’’W_(800_CFM_23/(05-03)_DTH800_-_Heavy_dusts_&_smoke_-_Self_cleaning_filter_system_built_in_-_24''D_X_32’’W_(800_CFM.jpg)
pre-engineered downdraft table complete with 1 Clean 2® 150 ft2 cartridge filter, integrated fan with TEFC direct drive class II motor and external dust tray generating 800 CFM with 150 FPM downdraft velocity. The DTH-800 draws contaminants away from workers’ breathing zone without hindering movement making these tables an ideal solutions for most welding and light dust/smoke applications.
Attachments
001 - Spec Drawings:
002 - Brochures:
003 - Case Studies:
004 - Videos:
017 - DWG and RVT models:
Buyer Guides:
(05-04) DTH1700 - Heavy dusts & smoke - Self cleaning filter system built in - 24''D X 48’’W (1,700 CFM)* **
_DTH1700_-_Heavy_dusts_&_smoke_-_Self_cleaning_filter_system_built_in_-_24''D_X_48’’W_(1700_C_49/(05-04)_DTH1700_-_Heavy_dusts_&_smoke_-_Self_cleaning_filter_system_built_in_-_24''D_X_48’’W_(1700_C.jpg)
The DTH-1700 is a Self-Contained pre-engineered Down Draft table comes complete with an integrated Fan and filtration system in addition to it's 24"D X 48"W work surface and 18" tall removable side & back shields generating 1400 CFM with 208 FPM downdraft velocity. The DTH-1700 draws contaminants away from workers’ breathing zone without hindering movement; large work area meets range of applications. Its use of (2) CLEAN-2 cartridge filters and the manual VIBRA-PULSE filter cleaning system makes this unit the ideal solution for most welding and light dust/smoke applications.
Attachments
001 - Spec Drawings:
002 - Brochures:
003 - Case Studies:
004 - Videos:
017 - DWG and RVT models:
Buyer Guides:
(05-05) DT3000V2 - Heavy dusts & smoke - Self cleaning filter system built in - 42''D X 66’’W or 42'' X 96 (3,000-4500 CFM)**
_DT3000V2_-_Heavy_dusts_&_smoke_-_Self_cleaning_filter_system_built_in_-_42''D_X_66’’W_or_42'_373/(05-05)_DT3000V2_-_Heavy_dusts_&_smoke_-_Self_cleaning_filter_system_built_in_-_42''D_X_66’’W_or_42'.jpg)
The DT3000 is a completely self-contained pre-engineered Downdraft table. Comes complete with an integrated 3HP or 5HP energy saving blower, high efficiency cartridge filters and automatic self-cleaning system. Available in 2 standard sizes: 66" X 42" or 96 X 42" work surfaces at heights of 33".
The DT3000 draws contaminants away from workers’ breathing zone without hindering movement; and allowing the workers to work/walk around all sides of the table. The DT-3000 uses (6) CLEAN-2 ULTRA high efficiency cartridge filters (150 SQ. FT. of media each / 900 SQ. FT. total) and the VIBRA-PULSE filter cleaning system allows those filters to be cleaned in place when they become saturated. All you have to do is activated the cleaning system and empty the tray.
One of 2 powerful fan/motor combinations generate between 3000 and 4500 CFM.
This solution is ideal for most welding, Grinding and cutting applications.
The DT3000 draws contaminants away from workers’ breathing zone without hindering movement; and allowing the workers to work/walk around all sides of the table. The DT-3000 uses (6) CLEAN-2 ULTRA high efficiency cartridge filters (150 SQ. FT. of media each / 900 SQ. FT. total) and the VIBRA-PULSE filter cleaning system allows those filters to be cleaned in place when they become saturated. All you have to do is activated the cleaning system and empty the tray.
One of 2 powerful fan/motor combinations generate between 3000 and 4500 CFM.
This solution is ideal for most welding, Grinding and cutting applications.
Attachments
001 - Spec Drawings:
002 - Brochures:
003 - Case Studies:
004 - Videos:
017 - DWG and RVT models:
Buyer Guides:
(05-06) ALH1 Aluminum Dust NFPA - 24''D X 32’’W (800 CFM); 24''D X 48’’W (1,700 CFM)**
_ALH1_Aluminum_Dust_NFPA_-_24''D_X_32’’W_(800_CFM)_24''D_X_48’’W_(1700_CFM)_91/(05-06)_ALH1_Aluminum_Dust_NFPA_-_24''D_X_32’’W_(800_CFM)_24''D_X_48’’W_(1700_CFM).jpg)
Downdraft table that Meets NFPA 651 for processing and finishing aluminum when properly used and maintained.
Integral Collection Area and Work Surface Draws contaminants away from workers' breathing zone without hindering movement, open work area meets range of applicationsDirect-Drive Blower: Higher static pressure, longer filter life and greater reliability; no belts or pulleys to replace.
Non-electrostatic Operation: High reliability, low maintenance.
Ultra-Seal® Filter Mounting: Eliminates contaminant bypass of filters.
Optional Casters: 5" casters and 8" wheels for portability.
Ergonomic Cabinet: Easy access speeds filter change out and maintenance.
800 CFM (150 FPM downdraft velocity)
Electrical meets NFPA Division II, group-E for aluminum dust.
Integral Collection Area and Work Surface Draws contaminants away from workers' breathing zone without hindering movement, open work area meets range of applications
Attachments
001 - Spec Drawings:
002 - Brochures:
003 - Case Studies:
004 - Videos:
017 - DWG and RVT models:
(05-08) AL6 Aluminum Dust NFPA - 42''D X 66''W (+ 3,000 CFM)**
_AL6_Aluminum_Dust_NFPA_-_42''D_X_66''W_(+_3000_CFM)_372/(05-08)_AL6_Aluminum_Dust_NFPA_-_42''D_X_66''W_(+_3000_CFM).jpg)
3000 CFM heavy duty downdraft table to collect aluminum dust with its 42"D x 66"W work surface at a height of 33". This unit boasts 155 fpm downdraft velocity and includes 18" tall aluminum side and back shields. Self-contained pre-engineered downdraft table to allow for maximum, precise and energy efficient capture. Unit includes: Filtration efficiency of 99% @ 1 micron, front door for easy access to filters, and a preventative Pressure Gauge to be able to maintain and monitor the filters status, all backed by the ULTRACLEAN-PLUS™ cartridge filters (150 sq. ft. of media each)
Attachments
001 - Spec Drawings:
002 - Brochures:
017 - DWG and RVT models:
(05-11) DT-23 General Purpose - 24''D x 36''W (flow to suit)**
_DT-23_General_Purpose_-_24''D_x_36''W_(flow_to_suit)_194/(05-11)_DT-23_General_Purpose_-_24''D_x_36''W_(flow_to_suit).jpg)
Non-Powered Down Draft table complete with integrated collection area and 2' X 3' work surface. Draws contaminants away from workers’ breathing zone without hindering movement.
Attachments
001 - Spec Drawings:
002 - Brochures:
004 - Videos:
007 - Written Specifications:
017 - DWG and RVT models:
(05-12) DT-35 (60''W x 36''D – flow to suit) **
_DT-35_(60''W_x_36''D_–_flow_to_suit)_50/(05-12)_DT-35_(60''W_x_36''D_–_flow_to_suit).jpg)
Non-Powered Down Draft table complete with integrated collection area and 3' X 5' work surface. Draws contaminants away from workers’ breathing zone without hindering movement.
Attachments
001 - Spec Drawings:
002 - Brochures:
003 - Case Studies:
004 - Videos:
017 - DWG and RVT models:
(05-15) Sledgehammer Series Downdraft Tables **
_Sledgehammer_Series_Downdraft_Tables_703/(05-15)_Sledgehammer_Series_Downdraft_Tables.jpg)
The 'Sledgehammer' © series downdraft tables are designed to be a dual purpose Work station and Extraction solution.
These tables draw contaminants away from workers’ breathing zone without hindering movement. Additionally, they provide a the most durable ¼” steel plate work surface (36” X 24”) on the market. Hence the name “Sledgehammer” ©
The SLEDGEHAMMER is equipped with Jet-Pulse Cleaning that allows simple cleaning of the filter, which reduces filter costs dramatically*.
Applications Include filtering of contaminants from the following applications: welding, grinding, de-burring, plastics, composites, sampling, batching, weighing, soldering, and finishing processes
All contaminated air is filtered and returned to the facility.
Please select filter options according to your application… when proper filters are selected, all ‘’Sledgehammer’’ © series downdraft tables comply to all Local and Federal clean air requirements.
Need a larger work surface? Quite often the area at which the fume or contaminant is generated is much smaller than the work table required… In these cases, either place the “sledgehammer” © series table in the middle of 2 or more work tables or bolt multiple downdraft tables together (Contact your distributor for quantity discounts).
These tables draw contaminants away from workers’ breathing zone without hindering movement. Additionally, they provide a the most durable ¼” steel plate work surface (36” X 24”) on the market. Hence the name “Sledgehammer” ©
The SLEDGEHAMMER is equipped with Jet-Pulse Cleaning that allows simple cleaning of the filter, which reduces filter costs dramatically*.
Applications Include filtering of contaminants from the following applications: welding, grinding, de-burring, plastics, composites, sampling, batching, weighing, soldering, and finishing processes
All contaminated air is filtered and returned to the facility.
Please select filter options according to your application… when proper filters are selected, all ‘’Sledgehammer’’ © series downdraft tables comply to all Local and Federal clean air requirements.
Need a larger work surface? Quite often the area at which the fume or contaminant is generated is much smaller than the work table required… In these cases, either place the “sledgehammer” © series table in the middle of 2 or more work tables or bolt multiple downdraft tables together (Contact your distributor for quantity discounts).
Attachments
001 - Spec Drawings:
002 - Brochures:
Buyer Guides:
(06-09) Weldstation 5 (60'' X 39'' X 120'' 2000 CFM)
_Weldstation_5_(60''_X_39''_X_120''_2000_CFM)_455/(06-09)_Weldstation_5_(60''_X_39''_X_120''_2000_CFM).jpg)
The Weldstation 5 is a one piece, self contained welding work center. Measuring just 60" wide, 39" deep and 120" high, the WeldStation 5 is designed to fit into almost any space. This machine is so effective you will wonder where the welding smoke or grinding dust has gone! Available options include adjustable height worktables, side shelving, welding equipment and worker storage, and interior lighting.
The WeldStation 5 will provide an excellent solution to your welding smoke and grinding dust removal!No duct work needed Shipped complete Just position, plug and play Ergonomically designed High performance Small footprint, just 60"wide x 39" deep x 120" high Illuminates the work area with effective lighting Continuous duty, operates 24/7 Self contained - no installation required Organizes work area by incorporating the welding equipment and table or fixture Can be installed against a wall, side by side or back to back Complete electrical package including pulse cleaning system standard Options include: adjustable height work tables, Welder storage and interior lighting
The WeldStation 5 will provide an excellent solution to your welding smoke and grinding dust removal!
Attachments
001 - Spec Drawings:
002 - Brochures:
Solutions forBack & Side Draft Systems
Back & Side Draft Systems

(06-04) Panel Filter Power Booth Modules (size/flow to suit)**
_Panel_Filter_Power_Booth_Modules_(sizeflow_to_suit)_627/(06-04)_Panel_Filter_Power_Booth_Modules_(sizeflow_to_suit).jpg)
5500 CFM free standing Panel filter collector packed into a 2' x 4' footprint is a complete dust collection system, standard with (12) MERV11 24x24x6 filters (42 sq. ft. each).
It can be used as stand alone unit or as part of an expandable dust control booth.
It can be used as stand alone unit or as part of an expandable dust control booth.
(06-05) PB Back Draft Modules - Dust - Self cleaning filter system built in - 4’ X 4’ BD Hood (5,000 CFM/module)**
_PB_Back_Draft_Modules_-_Dust_-_Self_cleaning_filter_system_built_in_-_4’_X_4’_BD_Hood_(5000__116/(06-05)_PB_Back_Draft_Modules_-_Dust_-_Self_cleaning_filter_system_built_in_-_4’_X_4’_BD_Hood_(5000_.jpg)
A free standing Dust Control Booth with 6 Clean 2® cartridge filters, dual dust drawers, slotted inlet hood, 5 HP 208-230/460/575/3/60hz motor with non-sparking AMCA Type B wheel, Vibra-Pulse® cleaning.
Attachments
001 - Spec Drawings:
002 - Brochures:
003 - Case Studies:
004 - Videos:
017 - DWG and RVT models:
(06-06) Back Draft Hoods & Booths - Sizes and flowrates to suit **
_Back_Draft_Hoods_&_Booths_-_Sizes_and_flowrates_to_suit_120/(06-06)_Back_Draft_Hoods_&_Booths_-_Sizes_and_flowrates_to_suit.jpg)
Description needed.
Attachments
001 - Spec Drawings:
002 - Brochures:
006 - System Layouts:
017 - DWG and RVT models:
Solutions forUpdraft & Overhead Capture Systems
Updraft & Overhead Capture Systems

(07-01) LEV Overhead Hoods - Smoke - Washable and/or disposable filters - 4’X4’ to 12’X20’ (flow to suit)**
_LEV_Overhead_Hoods_-_Smoke_-_Washable_andor_disposable_filters_-_4’X4’_to_12’X20’_(flow_to_s_613/(07-01)_LEV_Overhead_Hoods_-_Smoke_-_Washable_andor_disposable_filters_-_4’X4’_to_12’X20’_(flow_to_s.jpg)
The LEV-Hood is a pre-engineered ventilation hood that completes with filters and fan. This ''Plug & Play'' design is ready to mount as a "free-hanging" system above a welding cell or work table and will collect/filter the smoke, fumes generated from a variety of industrial processes. The cleaned air is then re-circulated to the plant delivering additional energy savings and environmental benefits.
Most Systems can be put in position with minimal mechanical installation time, typical 2 hours/2 men per hood. Electrical motor and lighting connections are also required.
This is an excellent solution when at-the-source capture of pollutants is not possible, practical or convenient. Simply put this is a nice quiet efficient and effective air filtration system.
A high efficiency, 3-stage filtration system. The first stage of filtration is a 2" baffle filter used for spark arrestance. The 2nd stage is a 40% pleated pre-filter that will trap dust and larger particles . The 3rd stage is a 95% micro-glass multi-pocket bag filter that will remove smoke and other sub-micron size particles from the air.
Most Systems can be put in position with minimal mechanical installation time, typical 2 hours/2 men per hood. Electrical motor and lighting connections are also required.
This is an excellent solution when at-the-source capture of pollutants is not possible, practical or convenient. Simply put this is a nice quiet efficient and effective air filtration system.
A high efficiency, 3-stage filtration system. The first stage of filtration is a 2" baffle filter used for spark arrestance. The 2nd stage is a 40% pleated pre-filter that will trap dust and larger particles . The 3rd stage is a 95% micro-glass multi-pocket bag filter that will remove smoke and other sub-micron size particles from the air.
Attachments
001 - Spec Drawings:
002 - Brochures:
003 - Case Studies:
017 - DWG and RVT models:
(07-02) F91 Suspended System with Extraction Arms - Smoke & Dust - 1 or 2 Arms 7'' Ø (650-1,300 CFM)* **
_F91_Suspended_System_with_Extraction_Arms_-_Smoke_&_Dust_-_1_or_2_Arms_7''_Ø_(650-1300_CFM)_61/(07-02)_F91_Suspended_System_with_Extraction_Arms_-_Smoke_&_Dust_-_1_or_2_Arms_7''_Ø_(650-1300_CFM).jpg)
Source capture, single arm unit, 2” mesh pre-filter, 95% bag main filter, single arm inlet plenum, 10’ long, E-Z ARM® overhead self-supporting pickup arm. Rated 1200 CFM. Includes Class II B.I. blower direct drive, 3 HP motor, 3ø
Attachments
001 - Spec Drawings:
002 - Brochures:
004 - Videos:
017 - DWG and RVT models:
(07-03) F122 Suspended System with Extraction Arms - Smoke & Dust - 1 or 2 Arms 7'' Ø (1,000-2,000 CFM)**
_F122_Suspended_System_with_Extraction_Arms_-_Smoke_&_Dust_-_1_or_2_Arms_7''_Ø_(1000-2000_CFM_89/(07-03)_F122_Suspended_System_with_Extraction_Arms_-_Smoke_&_Dust_-_1_or_2_Arms_7''_Ø_(1000-2000_CFM.jpg)
Source capture, dual arm unit, includes model F120- 2AL-95 unit, inlet plenum and 2 pickup arms E-Z ARM® x 10’ long self-supporting, 2000 CFM. Includes Class II B.I. blower and direct drive 3 HP motor.
Attachments
001 - Spec Drawings:
002 - Brochures:
004 - Videos:
017 - DWG and RVT models:
(07-04) HC4 Suspended System with Extraction Arms/Self cleaning filters - Smoke & Dust - 1 or 2 Arms 7'' Ø (1,000-2,000 CFM)**
_HC4_Suspended_System_with_Extraction_ArmsSelf_cleaning_filters_-_Smoke_&_Dust_-_1_or_2_Arms__88/(07-04)_HC4_Suspended_System_with_Extraction_ArmsSelf_cleaning_filters_-_Smoke_&_Dust_-_1_or_2_Arms_.jpg)
Horizontal cartridge collector w/4 Clean-2® cartridge filters (150ft² of media each). Comes complete with either DUAL inlets or (2) 10’ long E-Z Arm® high flow extractors (with damper and light in hood), AUTO-CLEAN VIBRA-PULSE® filter cleaning system, a 3 HP TEFC motor and a ½” NPT regulator. 2000 CFM
Attachments
001 - Spec Drawings:
002 - Brochures:
003 - Case Studies:
004 - Videos:
017 - DWG and RVT models:
(07-05) HC-4-Flexi **
_HC-4-Flexi_235/(07-05)_HC-4-Flexi.jpg)
Horizontal cartridge collector w/4 Clean-2® filter cartridges. Comes prepared to accept up to 4 Flexi© Extractor Arms (ordered separately), which allows for excellent extraction right at source. This solution is ideal when a packaged "Pre-engineered" solution is required. Suitable for most welding and light dust applications.
Attachments
001 - Spec Drawings:
(07-07) MC-2500 free hanging air cleaner for use extraction arms or ducted connections**
_MC-2500_free_hanging_air_cleaner_for_use_extraction_arms_or_ducted_connections_841/(07-07)_MC-2500_free_hanging_air_cleaner_for_use_extraction_arms_or_ducted_connections.jpg)
Air cleaner with 2 or 4 connections. Extraction arms can be direct or remote mounted. Collector comes complete with filter, Fan and silencer. 2400 CFM 230-460-600V/3/60
Attachments
002 - Brochures:
Solutions forDust, Fume & Vapor Control Booths
Dust, Fume & Vapor Control Booths

(08-01) Fume/Booth - Odors and Lights dusts - 2’ X 2’ Opening (230 CFM)**
_FumeBooth_-_Odors_and_Lights_dusts_-_2’_X_2’_Opening_(230_CFM)_441/(08-01)_FumeBooth_-_Odors_and_Lights_dusts_-_2’_X_2’_Opening_(230_CFM).jpg)
A ductless, portable desktop and bench top system for the removal of fumes, dust, smoke, odors and gases in a compact design.
Attachments
001 - Spec Drawings:
002 - Brochures:
003a - Video Case Study:
004 - Videos:
017 - DWG and RVT models:
(08-02) Paintbooth - Volatile Organic Compounds & Spray Painting - 800 24''D X 32''W X 36”H (800 CFM)**
_Paintbooth_-_Volatile_Organic_Compounds_&_Spray_Painting_-_800_24''D_X_32''W_X_36”H_(800_CFM_149/(08-02)_Paintbooth_-_Volatile_Organic_Compounds_&_Spray_Painting_-_800_24''D_X_32''W_X_36”H_(800_CFM.jpg)
600 CFM Portable Paint Booth. Includes access door for filter removal, removable panel for access to direct drive motor/blower compartment, casters, acoustically lined blower cabinet and BF3 enclosure.
Attachments
001 - Spec Drawings:
002 - Brochures:
003 - Case Studies:
004 - Videos:
007 - Written Specifications:
(08-03) Panel Booth - Light dust & Volatile Organic Compounds - Booth sizes to suit & flow to suit **
_Panel_Booth_-_Light_dust_&_Volatile_Organic_Compounds_-_Booth_sizes_to_suit_&_flow_to_suit_643/(08-03)_Panel_Booth_-_Light_dust_&_Volatile_Organic_Compounds_-_Booth_sizes_to_suit_&_flow_to_suit.jpg)
LEV-CO’S PANEL BOOTH is a fully customized dust booth that allows the selection of the precise filter components to control emissions from your specific process. When selecting these components, we take into consideration the following aspects of your process:
Contaminant
Concentration
Particle Size
Dispersion Velocity
Buoyancy
Temperature
Worker Position Effect
Specific Gravity Relative to Air
Understanding that ALL PROCESSES ARE NOT CREATED EQUAL, Lev-Co’s panel booths are designed to improve worker health and safety, and production efficiency.
Standard booth construction is 10 gauge insulated galvanized panels up to 10’ high. Advanced Core Insulation – sound-absorbing mats of two (2) inch fiberglass compressed to one (1) inch. Outer Layer – this outer layer further enhances sound attenuation with five (5) mil aluminized vinyl-impregnated fiberglass cloth covering of mat.
As noted above, filter media is selected to your precise contaminant and process and is further detailed on your quote and submittals.
Maintenance is a breeze with easy to change filters being either washable, disposable, or refillable.
All systems are sold with a VFD and are thus both energy efficient and quiet.
Understanding that ALL PROCESSES ARE NOT CREATED EQUAL, Lev-Co’s panel booths are designed to improve worker health and safety, and production efficiency.
Standard booth construction is 10 gauge insulated galvanized panels up to 10’ high. Advanced Core Insulation – sound-absorbing mats of two (2) inch fiberglass compressed to one (1) inch. Outer Layer – this outer layer further enhances sound attenuation with five (5) mil aluminized vinyl-impregnated fiberglass cloth covering of mat.
As noted above, filter media is selected to your precise contaminant and process and is further detailed on your quote and submittals.
Maintenance is a breeze with easy to change filters being either washable, disposable, or refillable.
All systems are sold with a VFD and are thus both energy efficient and quiet.
Attachments
001 - Spec Drawings:
002 - Brochures:
003 - Case Studies:
017 - DWG and RVT models:
(08-07) ZINCOCAR DF - Booth for dust and smokes
_ZINCOCAR_DF_-_Booth_for_dust_and_smokes_913/(08-07)_ZINCOCAR_DF_-_Booth_for_dust_and_smokes.jpg)
Booth for dust and smokes
Suction and filtering of:WOOD SANDING DUSTS STEEL SANDING/GRINDING DUSTS WELDING FUMES DUSTS FROM INERT MATERIALS WORKING DUSTS FROM SURFACE METALLIZATION
The sanding booth ZINCOCAR DF has been studied according to modern criteria of plug & play, easy maintenance, maximum filtration efficiency and easy stand along positioning.
Designed for various applications in workshops where:
Local/source exhaust is difficult or not possible
Ductwork installation is complicated or not suitable
Air-conditioned or heated workshops to avoid energy waste in axhausting the air outdoor and the need to recycle the outside air
Environments where the source of pollutant/smoke is changing depending on process
Insufficient local exhaust performed by portable units or weak filtering capability of the existing pollution control system
Suction and filtering of:
The sanding booth ZINCOCAR DF has been studied according to modern criteria of plug & play, easy maintenance, maximum filtration efficiency and easy stand along positioning.
Designed for various applications in workshops where:
(08-08) Minispray Dry Painting Booth **
_Minispray_Dry_Painting_Booth_928/(08-08)_Minispray_Dry_Painting_Booth.png)
By means of the centrifugal fan mounted on the top of the booth, negative pressure is created, drawing air through the filters. This flow draws the particles of paint suspended in the air to the filters without any dispersion in the surrounding environment. The first stage of filtration blocks the larger particles of paint and the second, made of fiberglass, blocks the finer particles; the air purified of solid pigments is expelled by the fan. The Minispray dry painting booths are designed to ensure versatility, modularity and efficiency. They consist entirely of zinc-plated panels bolted together: the side panels and dividers are self supported. The extracting front has filter holding grooves set for housing a double filtering system. On top, is the spark proof centrifugal fan. Dimensions and Weight: 98"x42"x42" at 550lbs (casters included)
(08-09) Minidry Painting Booth* **
_Minidry_Painting_Booth_929/(08-09)_Minidry_Painting_Booth.png)
Suitable for painting small pieces, for small series or final touches. With fans fitted with a high-performance backward inclined spark proof impeller and a revolving part holder. They are supplied fitted with a paper filter.
Solutions forAmbient Air Cleaners
Ambient Air Cleaners

(09-00) 1000 Free hanging filter - (1000 CFM)* **
_1000_Free_hanging_filter_-_(1000_CFM)_29/(09-00)_1000_Free_hanging_filter_-_(1000_CFM).jpg)
1000 CFM Wall mounted Air cleaner. This unit comes complete with; 1" washable urethane foam pre-filter, 95% bag filter (39 sq. ft. of media), 1/2" charcoal filter, ODOR/EX deodorizer and wall mounting bracket/cleat.
This system is best suited for air cleaning applications involving small rooms, offices, restaurants or warehouses. When selecting this unit for industrial uses, the "Reduced Maintenance" pre-filter model is recommended.
This system is best suited for air cleaning applications involving small rooms, offices, restaurants or warehouses. When selecting this unit for industrial uses, the "Reduced Maintenance" pre-filter model is recommended.
Attachments
001 - Spec Drawings:
002 - Brochures:
(09-01) F70R - Light Airborne Dust & Smoke - Washable and/or disposable filters - Flow Through Style (2,500 CFM)* **
_F70R_-_Light_Airborne_Dust_&_Smoke_-_Washable_andor_disposable_filters_-_Flow_Through_Style__228/(09-01)_F70R_-_Light_Airborne_Dust_&_Smoke_-_Washable_andor_disposable_filters_-_Flow_Through_Style_.jpg)
2500 CFM "Free-Hanging" (also called "Packaged") reduced maintenance air cleaner complete with an integrated Blower and filter system. Ideal for "Cross-Dilution" and filtration of airborne pollutants that can't be easily captured at source. The F70-R filter unit comes standard with (1) 10ft² reduced maintenance pre-filter; (1) micro-glass multipocket bag filter 65% efficiency;(1) 3/4 HP totally enclosed, 2-speed motor 115/1/60Hz.
Attachments
001 - Spec Drawings:
002 - Brochures:
003 - Case Studies:
004 - Videos:
017 - DWG and RVT models:
(09-02) T-3000 - Light Airborne Dust & Smoke - Washable and/or disposable filters - T style (3,000 CFM) **
_T-3000_-_Light_Airborne_Dust_&_Smoke_-_Washable_andor_disposable_filters_-_T_style_(3000_CFM_603/(09-02)_T-3000_-_Light_Airborne_Dust_&_Smoke_-_Washable_andor_disposable_filters_-_T_style_(3000_CFM.jpg)
Collects dust, smoke and other airborne pollutants in factories, schools, shops, labs, assembly areas and repair shops with a high a high efficiency, 2-stage filtration system. A complete, packaged air filter unit designed as a “free hanging” system for efficient and economical air cleaning when at-the-source capture of pollutants is not possible or practical. Strategic placement of one or several units in an area will result in dramatic reduction of the bothersome smoke, dust or haze in your facility. The first stage of filtration is a 40% pleated pre-filter that will trap dust and larger particles. The second stage is a micro-glass multi-pocket bag filter that will remove smoke and other sub-micron size particles from the air.
Attachments
001 - Spec Drawings:
002 - Brochures:
003 - Case Studies:
004 - Videos:
017 - DWG and RVT models:
(09-07) AIRPOD Series: Models 1, 2 & 3 (size/flow to suit)* **
_AIRPOD_Series_Models_1_2_&_3_(sizeflow_to_suit)_659/(09-07)_AIRPOD_Series_Models_1_2_&_3_(sizeflow_to_suit).jpg)
Free-standing Ambient Collection System. AirPods consists of 1 to 3 modules that stack up to three modules high easily adapting to multiple filtration configurations. AirPod™ Air Filtration Process: Airborne dusts & gases that settle at floor level are drawn into the four-sided air intake. Contaminated air is filtered and discharged vertically above the work area. By drawing in the air near the floor, Cooled air is discharged into the warmer air near the ceiling creating an effective dilutionary & energy savings air pattern.
Construction: 12/14/16 ga. Welded zinc coated steel cabinet with powder-coat finish - Blue
Construction: 12/14/16 ga. Welded zinc coated steel cabinet with powder-coat finish - Blue
Attachments
001 - Spec Drawings:
(09-09) TC-4 - Heavy Airborne Dust & Smoke - T style with Self Cleaning filter system (4,000 CFM) **
_TC-4_-_Heavy_Airborne_Dust_&_Smoke_-_T_style_with_Self_Cleaning_filter_system_(4000_CFM)_104/(09-09)_TC-4_-_Heavy_Airborne_Dust_&_Smoke_-_T_style_with_Self_Cleaning_filter_system_(4000_CFM).jpg)
2650 CFM "SELF-CLEANING" Air cleaner. This "T" style "free-Hanging" or "Packaged" air cleaner. This solution is ideal for Heavy dust loading applications or applications involving hard to reach areas where regular maintenance of the collector would be impractical. Comes complete with (4) Clean-2® cartridge filters, (150ft² of media each), ON-DEMAND, AUTO-CLEAN VIBRA-PULSE® filter cleaning system, 3 HP TEFC motor and a ½” NPT regulator.
Attachments
001 - Spec Drawings:
002 - Brochures:
017 - DWG and RVT models:
(09-10) FM600 Commercial - Dust & Odors - Washable and/or disposable filters - 2’ X 2’ T - Bar Mount (600 CFM)* **
_FM600_Commercial_-_Dust_&_Odors_-_Washable_andor_disposable_filters_-_2’_X_2’_T_-_Bar_Mount__69/(09-10)_FM600_Commercial_-_Dust_&_Odors_-_Washable_andor_disposable_filters_-_2’_X_2’_T_-_Bar_Mount_.jpg)
600 CFM Flush Mount Unit. Fits in a standard 2’ x 2’ ceiling tile opening. Includes (1) ½” aluminum mesh pre-filter, (1) 95% main filter (14ft²), (1) ½” charcoal after-filter and an ODOR/EX deodorizer.
Attachments
001 - Spec Drawings:
002 - Brochures:
017 - DWG and RVT models:
(09-11) FM1000 Commercial - Dust & Odors - Washable and/or disposable filters - 2’ X 4’ T - Bar Mount (1,000 CFM)* **
_FM1000_Commercial_-_Dust_&_Odors_-_Washable_andor_disposable_filters_-_2’_X_4’_T_-_Bar_Mount_82/(09-11)_FM1000_Commercial_-_Dust_&_Odors_-_Washable_andor_disposable_filters_-_2’_X_4’_T_-_Bar_Mount.jpg)
Flush mount 1000 CFM units, fits in 2 x 4 ceiling tile.
Attachments
001 - Spec Drawings:
002 - Brochures:
017 - DWG and RVT models:
(09-12) T140 - Light Airborne Dust & Smoke - Washable and/or disposable filters - T style (3,600/4,500 CFM)* **
_T140_-_Light_Airborne_Dust_&_Smoke_-_Washable_andor_disposable_filters_-_T_style_(36004500_C_68/(09-12)_T140_-_Light_Airborne_Dust_&_Smoke_-_Washable_andor_disposable_filters_-_T_style_(36004500_C.jpg)
3600-4500 CFM "Free-Hanging" T-STYLE air cleaner complete with an integrated Blower and filter system. Ideal for "Cross-Dilution" and filtration of airborne pollutants that can't be easily captured at source. The T-STYLE configuration allows the contaminated air to enter from both ends of the unit and the cleaned air to exit from the center of the housing. This allows the air to be filtered by twice the media resulting in a much lower "AIR-TO-CLOTH" ratio which in turn means greater filter life, quite often 2 to 4 times the average filter life of that of a regular uni-directional "Flow-Through" filter system. The center exhaust also allows for better dilution of the contaminated air, and in the case of large plants, it has an added energy saving effect. Latent heat, high up in the plant is de-stratified when the exhaust vents are directed upwards, towards the center of the ceiling. This results in not only a much more comfortable working environment, but also has a sizable energy saving effect through a better distribution of the conditioned air throughout the building. Each "Free-Hanging" (also called "Packaged"), air cleaner comes complete with 65% eff.. filters, Direct drive blower, 208,230,460,575V/3/60 TEFC, 2 HP motor, Single speed motor. Unit comes standard in a blue baked-on powder coated finish.
Attachments
001 - Spec Drawings:
002 - Brochures:
004 - Videos:
Solutions forDucted Air Cleaners
Ducted Air Cleaners

(10-00) 1000-D Commercial ''In-Line'' Filter housing and booster fans – (1000 CFM)* **
_1000-D_Commercial_''In-Line''_Filter_housing_and_booster_fans_–_(1000_CFM)_296/(10-00)_1000-D_Commercial_''In-Line''_Filter_housing_and_booster_fans_–_(1000_CFM).jpg)
Model 1000 above ceiling air cleaner, 1000 CFM. Includes 2” polyester pre-filter, 95% main filter 39 ft2, ½” charcoal after filter and ODOR/EX deodorizer cartridge, ½ HP, 115V, 2 speed motor, 7.4 amps, includes 2 speed wall switch, one 12” outlet, (2) 8” inlets.
Attachments
001 - Spec Drawings:
(10-01) F90 - Dusts, Mists & Gases - Multiple filter configurations available / Washable and/or Disposable filters - With Fan (500-2,000 CFM)* **
_F90_-_Dusts_Mists_&_Gases_-_Multiple_filter_configurations_available_Washable_andor_Disposab_97/(10-01)_F90_-_Dusts_Mists_&_Gases_-_Multiple_filter_configurations_available_Washable_andor_Disposab.jpg)
500 - 2000 CFM Ducted Industrial Air Cleaner that comes standard with (1) 4” deep 30% pleated pre-filter, (1) 65% bag filter, 96ft² of media, and a 1.5 HP TEFC motor 208-230/460/575/3/60Hz (5/2.5 amps). Unit can be upgraded with different filter and fan packages to suit a variety of applications and contaminants.
Attachments
001 - Spec Drawings:
002 - Brochures:
017 - DWG and RVT models:
(10-02) F120 - Dusts, Mists & Gases - Multiple filter configurations available / Washable and/or Disposable filters - With Fan (1,000-2,000 CFM**)
_F120_-_Dusts_Mists_&_Gases_-_Multiple_filter_configurations_available_Washable_andor_Disposa_140/(10-02)_F120_-_Dusts_Mists_&_Gases_-_Multiple_filter_configurations_available_Washable_andor_Disposa.jpg)
1000 - 2000 CFM Ducted Industrial Air Cleaner that comes standard with (1) 4” deep 30% pleated pre-filter, (1) 65% bag filter, 120ft² of media, and a 2.0 HP TEFC motor 208-230/460/575/3/60Hz. Unit can be upgraded with different filter and fan packages to suit a variety of applications and contaminants.
Attachments
0001 - Installation Examples - How products go together:
001 - Spec Drawings:
002 - Brochures:
003 - Case Studies:
004 - Videos:
017 - DWG and RVT models:
(10-03) F240 - Dusts, Mists & Gases - Multiple filter configurations available / Washable and/or Disposable filters - With Fan (2,000-4,000 CFM)* **
_F240_-_Dusts_Mists_&_Gases_-_Multiple_filter_configurations_available_Washable_andor_Disposa_46/(10-03)_F240_-_Dusts_Mists_&_Gases_-_Multiple_filter_configurations_available_Washable_andor_Disposa.jpg)
2000 – 4000 CFM Ducted Industrial Air Cleaner that comes standard with (2) 4” deep 30% pleated pre-filter, (2) 65% bag filter, 120ft² of media ea. and a 5 HP TEFC motor 208-230/460/575/3/60Hz. Unit can be upgraded with different filter and fan packages to suit a variety of applications and contaminants.
Attachments
001 - Spec Drawings:
002 - Brochures:
003 - Case Studies:
017 - DWG and RVT models:
(10-04) F360 - Dusts, Mists & Gases - Multiple filter configurations available / Washable and/or Disposable filters - With Fan (3,000-6,000 CFM) **
_F360_-_Dusts_Mists_&_Gases_-_Multiple_filter_configurations_available_Washable_andor_Disposa_209/(10-04)_F360_-_Dusts_Mists_&_Gases_-_Multiple_filter_configurations_available_Washable_andor_Disposa.jpg)
3000 – 6000 CFM Ducted Industrial Air Cleaner that comes standard with (3) 4” deep 30% pleated pre-filter, (3) 65% bag filter, 96ft² of media each, and a 10 HP TEFC motor 208-230/460/575/3/60Hz. Unit can be upgraded with different filter and fan packages to suit a variety of applications and contaminants.
Attachments
001 - Spec Drawings:
002 - Brochures:
017 - DWG and RVT models:
(10-05) F480 - Dusts, Mists & Gases - Multiple filter configurations available / Washable and/or Disposable filters - With Fan (4,000-8,000 CFM)**
_F480_-_Dusts_Mists_&_Gases_-_Multiple_filter_configurations_available_Washable_andor_Disposa_58/(10-05)_F480_-_Dusts_Mists_&_Gases_-_Multiple_filter_configurations_available_Washable_andor_Disposa.jpg)
4000 – 8000 CFM Ducted Industrial Air Cleaner that comes standard with (4) 4” deep 30% pleated pre-filter, (4) 65% bag filter, 96ft² of media each, and a 15 HP TEFC motor 208-230/460/575/3/60Hz. Unit can be upgraded with different filter and fan packages to suit a variety of applications and contaminants.
Attachments
001 - Spec Drawings:
002 - Brochures:
017 - DWG and RVT models:
(10-06) 200 - Dusts, Mists & Gases - Multiple filter configurations available / Washable and/or Disposable filters - No Fan (1,000-2,000 CFM**)
_200_-_Dusts_Mists_&_Gases_-_Multiple_filter_configurations_available_Washable_andor_Disposab_78/(10-06)_200_-_Dusts_Mists_&_Gases_-_Multiple_filter_configurations_available_Washable_andor_Disposab.jpg)
Blower-less filtration housing designed with up to 4 stages of filtration for industrial applications. Designed to handle airflow between 1000 & 2000 CFM , (multiple units can be combined for greater CFM). Filter system comes standard with (1) 4” deep 30% pleated pre-filter, (1) 65% bag filter, 120ft² of media. System can be upgraded with different filter and fan packages to suit a variety of applications and contaminants.
Attachments
001 - Spec Drawings:
002 - Brochures:
007 - Written Specifications:
017 - DWG and RVT models:
(10-07) 202 - Dusts, Mists & Gases - Multiple filter configurations available / Washable and/or Disposable filters - No Fan (2,000-4,000 CFM)
_202_-_Dusts_Mists_&_Gases_-_Multiple_filter_configurations_available_Washable_andor_Disposab_134/(10-07)_202_-_Dusts_Mists_&_Gases_-_Multiple_filter_configurations_available_Washable_andor_Disposab.jpg)
Blower-less filtration housing designed with up to 4 stages of filtration for industrial applications. Designed to handle airflow between 2000 & 4000 CFM , (multiple units can be combined for greater CFM). Filter system comes standard with (2) 4” deep 30% pleated pre-filter, (2) 65% bag filter, 120ft² of media (per filter). System can be upgraded with different filter and fan packages to suit a variety of applications and contaminants.
Attachments
001 - Spec Drawings:
002 - Brochures:
007 - Written Specifications:
017 - DWG and RVT models:
(10-08) 203 - Dusts, Mists & Gases - Multiple filter configurations available / Washable and/or Disposable filters - No Fan (3,000-6,000 CFM) **
_203_-_Dusts_Mists_&_Gases_-_Multiple_filter_configurations_available_Washable_andor_Disposab_162/(10-08)_203_-_Dusts_Mists_&_Gases_-_Multiple_filter_configurations_available_Washable_andor_Disposab.jpg)
Blower-less filtration housing designed with up to 4 stages of filtration for industrial applications. Designed to handle airflow between 3000 & 6000 CFM , (multiple units can be combined for greater CFM). Filter system comes standard with (3) 4” deep 30% pleated pre-filter, (3) 65% bag filter, 120ft² of media (per filter). System can be upgraded with different filter and fan packages to suit a variety of applications and contaminants.
Attachments
001 - Spec Drawings:
002 - Brochures:
007 - Written Specifications:
017 - DWG and RVT models:
(10-09) MicroAir Systems MC-3000 Air Cleaner **
_MicroAir_Systems_MC-3000_Air_Cleaner_715/(10-09)_MicroAir_Systems_MC-3000_Air_Cleaner.jpg)
Ceiling/wall mounted cartridge collector for source or ambient capture. Ambient or Source Capture of:Welding Smoke and Fumes Grinding Dust Powders Other Dry Dusts
Features: Revolutionary Roto-Pulse Filter Cleaning Systems High Capacity Allows for Multiple Drops Without a Loss In CFM Modular Design Built-In Silencer Plenum Hinged Door for Easy Filter Access Motor Starter/Overload Relay Standard After Pulse Cleaning Standard
Features:
Attachments
001 - Spec Drawings:
002 - Brochures:
Solutions forMist Collectors
Mist Collectors

(11-02) MP4 - Direct machine mount - Self Draining Filters / Horizontal Profile (Wider than tall) - Max Door Opening: 7 ft ² (475 CFM)**
_MP4_-_Direct_machine_mount_-_Self_Draining_Filters_Horizontal_Profile_(Wider_than_tall)_-_Ma_179/(11-02)_MP4_-_Direct_machine_mount_-_Self_Draining_Filters_Horizontal_Profile_(Wider_than_tall)_-_Ma.jpg)
The Model MP4 is designed for single-unit metalworking applications. It produces from 475 CFM with 95% filtration efficiency. It features a 1" aluminum mesh pre-filter, a Mist-Plus main filter, and a 3/4 HP BI blower TEFC motor. It includes the new removal bottom sump with 1.5" drain, mounting angles to hang or surface mount, and a 6" bottom inlet only. For side, back or front inlet see INLET PLENUM.
Attachments
001 - Spec Drawings:
002 - Brochures:
003 - Case Studies:
004 - Videos:
006 - System Layouts:
017 - DWG and RVT models:
(11-03) MPH8 - Direct machine mount - Self Draining Filters / Horizontal Profile (Wider than tall) - Max Door Opening: 11 ft ² (800 CFM)**
_MPH8_-_Direct_machine_mount_-_Self_Draining_Filters_Horizontal_Profile_(Wider_than_tall)_-_M_464/(11-03)_MPH8_-_Direct_machine_mount_-_Self_Draining_Filters_Horizontal_Profile_(Wider_than_tall)_-_M.jpg)
The Mist-Pak® MPH8 low profile mist collector is designed to capture mist and smoke from various metalworking applications. The low profile design allows the unit to be installed directly above the machine tool in low ceiling applications. The collector produces up to 800 CFM with 95%+ filtration efficiency for single or multiple machine tool collection systems.
Attachments
001 - Spec Drawings:
002 - Brochures:
006 - System Layouts:
017 - DWG and RVT models:
(11-04) MPH10 - Direct machine mount - Self Draining Filters / Horizontal Profile (Wider than tall) - Max Door Opening: 14 ft ² (1,000 CFM)**
_MPH10_-_Direct_machine_mount_-_Self_Draining_Filters_Horizontal_Profile_(Wider_than_tall)_-__664/(11-04)_MPH10_-_Direct_machine_mount_-_Self_Draining_Filters_Horizontal_Profile_(Wider_than_tall)_-_.jpg)
The Mist-Pak® MPH10 low profile mist collector is designed to capture mist and smoke from various metalworking applications. The low profile design allows the unit to be installed directly above the machine tool in low ceiling applications. The collector produces up to 1000 CFM with 95%+ filtration efficiency for single or multiple machine tool collection systems.
Attachments
001 - Spec Drawings:
002 - Brochures:
(11-05) MP14 - Centrally Ducted - Self Draining Filters / Vertical Profile (Taller than wide) - Max Door Opening: 19 ft ² (1,400 CFM)**
_MP14_-_Centrally_Ducted_-_Self_Draining_Filters_Vertical_Profile_(Taller_than_wide)_-_Max_Do_137/(11-05)_MP14_-_Centrally_Ducted_-_Self_Draining_Filters_Vertical_Profile_(Taller_than_wide)_-_Max_Do.jpg)
The Model MP14 is designed for medium-duty metalworking applications. It produces up to 1400 CFM with 95% filtration efficiency for single or multiple machine tool collection systems. This unit includes a 2" aluminum mesh pre-filter, 3 Mist-Plus main filters. Mounting angles to hang or surface mount unit and a 10" bottom inlet only (Use INLET PLENUM option for side back or front inlets).
Attachments
001 - Spec Drawings:
002 - Brochures:
003 - Case Studies:
004 - Videos:
006 - System Layouts:
017 - DWG and RVT models:
(11-06) MP30 - Centrally Ducted - Self Draining Filters / Vertical Profile (Taller than wide) - Max Door Opening: 40 ft ² (3,000) CFM **
_MP30_-_Centrally_Ducted_-_Self_Draining_Filters_Vertical_Profile_(Taller_than_wide)_-_Max_Do_64/(11-06)_MP30_-_Centrally_Ducted_-_Self_Draining_Filters_Vertical_Profile_(Taller_than_wide)_-_Max_Do.jpg)
The Model MP30 is designed for use in medium- to heavy-duty metalworking applications. It produces up to 3000 CFM with 95% filtration efficiency.
Attachments
001 - Spec Drawings:
002 - Brochures:
004 - Videos:
006 - System Layouts:
017 - DWG and RVT models:
(11-07) MP60 - Centrally Ducted - Self Draining Filters / Vertical Profile (Taller than wide) - Max Door Opening: 80 ft ² (6,000 CFM)**
_MP60_-_Centrally_Ducted_-_Self_Draining_Filters_Vertical_Profile_(Taller_than_wide)_-_Max_Do_30/(11-07)_MP60_-_Centrally_Ducted_-_Self_Draining_Filters_Vertical_Profile_(Taller_than_wide)_-_Max_Do.jpg)
6000 CFM source capture industrial air cleaner (14’Wx14”Dx30”H). It features a 2" aluminum mesh pre-filter, eight Mist-Plus main filters, a 10 HP TEFC motor, 24" high leg stand, and a 20" dia. (max) inlet collar mounted on either side or on back or 18" dia. (max) collar on front.
Attachments
001 - Spec Drawings:
002 - Brochures:
003 - Case Studies:
003a - Video Case Study:
004 - Videos:
006 - System Layouts:
017 - DWG and RVT models:
(11-08) MP120 - Centrally Ducted - Self Draining Filters / Vertical Profile (Taller than wide) - Max Door Opening: 160 ft ² (12,000 CFM)**
_MP120_-_Centrally_Ducted_-_Self_Draining_Filters_Vertical_Profile_(Taller_than_wide)_-_Max_D_9/(11-08)_MP120_-_Centrally_Ducted_-_Self_Draining_Filters_Vertical_Profile_(Taller_than_wide)_-_Max_D.jpg)
12000 CFM @ 2" ESP source capture industrial air cleaner (14’Wx14”Dx30”H) with mesh pre-filter, 95% Mist-Plus filter, and one 12” side inlet. Handing brackets furnished. It features two 2" aluminum mesh prefilters, sixteen Mist-Plus main filters, a 20 HP TEFC motor, a 28" dia. (max) inlet collar mounted on either side, and a 24" high leg stand
Attachments
001 - Spec Drawings:
002 - Brochures:
004 - Videos:
006 - System Layouts:
017 - DWG and RVT models:
(11-09) NOMEX - Ducted - Suitable for most Wet/Dry particulate or gas phase contaminants **
_NOMEX_-_Ducted_-_Suitable_for_most_WetDry_particulate_or_gas_phase_contaminants_573/(11-09)_NOMEX_-_Ducted_-_Suitable_for_most_WetDry_particulate_or_gas_phase_contaminants.jpg)
The NOMEX© filter boasts a high degree of separation… When used for oil mists the Nomex boasts a 95% efficiency on oil mists and up to 99.9% of particulates. The Nomex is also well suited to handle Gas Phase applications with the use of activated media modules. The oil mist filters are considered "life-time" that last a minimum of 5 years while the activated media needs to be changed out (Refilled) when the media becomes saturated.
Attachments
001 - Spec Drawings:
002 - Brochures:
003 - Case Studies:
006 - System Layouts:
017 - DWG and RVT models:
(11-13)MistPac (600 CFM) **
MistPac_(600_CFM)_145/(11-13)MistPac_(600_CFM).jpg)
600 CFM Source capture industrial air cleaner. System is ideal for mixed DUST & MIST machining applications such as tool room or multipurpose machine shop applications.
Attachments
001 - Spec Drawings:
002 - Brochures:
004 - Videos:
017 - DWG and RVT models:
(11-15) 1200 VOM (1200 CFM) **
_1200_VOM_(1200_CFM)_1/(11-15)_1200_VOM_(1200_CFM).jpg)
1200 CFM source capture industrial air cleaner. It features a 2" impingement pre-filter, a 2" aluminum mesh filter, a 95% main filter (25 sq. ft of media), a one HP TEFC motor, and a 8" dia. inlet in front only.
Attachments
001 - Spec Drawings:
002 - Brochures:
003 - Case Studies:
004 - Videos:
017 - DWG and RVT models:
(11-17) 2400 VOM (2400 CFM) **
_2400_VOM_(2400_CFM)_198/(11-17)_2400_VOM_(2400_CFM).jpg)
2400 CFM source capture industrial air cleaner. It features a 2" impingement pre-filter, a 2" aluminum mesh filter, a 95% main filter (88 sq. ft of media), a 1.5 HP motor, and a 12" dia. (max) inlet on the left side.
Attachments
001 - Spec Drawings:
002 - Brochures:
003 - Case Studies:
004 - Videos:
017 - DWG and RVT models:
(11-18) OM-3510**
_OM-3510_891/(11-18)_OM-3510.png)
Oil mist laden air flows through the inlet into the bottom of the unit where it turns 90 degrees. The air goes upward through the impinger, then the mesh prefilter, and finally through the special oil mist bag. Clean air is then discharged at the top of the unit. Oil drains out the bottom of the unit.
Attachments
001 - Spec Drawings:
002 - Brochures:
Solutions forCOVID-19 Ventilation & Air Filtration
COVID-19 Ventilation & Air Filtration

(12-02) MSF120-CV - Dusts, Mists & Gases - Multiple Filter Configurations Available / Washable and/or Disposable Filters - With Fan (1,000-2,000 CFM)
_MSF120-CV_-_Dusts_Mists_&_Gases_-_Multiple_Filter_Configurations_Available_Washable_andor_Di_942/(12-02)_MSF120-CV_-_Dusts_Mists_&_Gases_-_Multiple_Filter_Configurations_Available_Washable_andor_Di.jpg)
1000 - 2000 CFM Ducted Industrial Air Cleaner that comes standard with (1) 4” deep 30% pleated pre-filter, (1) 65% bag filter, 120ft² of media, and a 2.0 HP TEFC motor 208-230/460/575/3/60Hz. Unit can be upgraded with different filter and fan packages to suit a variety of applications and contaminants.
(12-03) MSF240-CV - Dusts, Mists & Gases - Multiple Filter Configurations Available / Washable and/or Disposable Filters - with Fan (2,000-4,000 CFM)
_MSF240-CV_-_Dusts_Mists_&_Gases_-_Multiple_Filter_Configurations_Available_Washable_andor_Di_943/(12-03)_MSF240-CV_-_Dusts_Mists_&_Gases_-_Multiple_Filter_Configurations_Available_Washable_andor_Di.jpg)
2000 – 4000 CFM Ducted Industrial Air Cleaner that comes standard with (2) 4” deep 30% pleated pre-filter, (2) 65% bag filter, 120ft² of media ea. and a 5 HP TEFC motor 208-230/460/575/3/60Hz. Unit can be upgraded with different filter and fan packages to suit a variety of applications and contaminants.
(12-04) MSF360-CV - Dusts, Mists & Gases - Multiple Filter Configurations Available / Washable and/or Disposable Filters - With Fan (3,000-6,000 CFM)
_MSF360-CV_-_Dusts_Mists_&_Gases_-_Multiple_Filter_Configurations_Available_Washable_andor_Di_944/(12-04)_MSF360-CV_-_Dusts_Mists_&_Gases_-_Multiple_Filter_Configurations_Available_Washable_andor_Di.jpg)
3000 – 6000 CFM Ducted Industrial Air Cleaner that comes standard with (3) 4” deep 30% pleated pre-filter, (3) 65% bag filter, 96ft² of media each, and a 10 HP TEFC motor 208-230/460/575/3/60Hz. Unit can be upgraded with different filter and fan packages to suit a variety of applications and contaminants.
(12-05) MS200-CV - Dusts, Mists & Gases - Multiple Filter Configurations Available / Washable and/or Disposable Filters - No Fan (1,000-2,000 CFM)
_MS200-CV_-_Dusts_Mists_&_Gases_-_Multiple_Filter_Configurations_Available_Washable_andor_Dis_946/(12-05)_MS200-CV_-_Dusts_Mists_&_Gases_-_Multiple_Filter_Configurations_Available_Washable_andor_Dis.jpg)
Blower-less filtration housing designed with up to 4 stages of filtration for industrial applications. Designed to handle airflow between 1000 & 2000 CFM , (multiple units can be combined for greater CFM). Filter system comes standard with (1) 4” deep 30% pleated pre-filter, (1) 65% bag filter, 120ft² of media. System can be upgraded with different filter and fan packages to suit a variety of applications and contaminants.
(12-06) MS202-CV - Dusts, Mists & Gases - Multiple Filter Configurations Available / Washable and/or Disposable Filters - No Fan (2,000-4,000 CFM)
_MS202-CV_-_Dusts_Mists_&_Gases_-_Multiple_Filter_Configurations_Available_Washable_andor_Dis_947/(12-06)_MS202-CV_-_Dusts_Mists_&_Gases_-_Multiple_Filter_Configurations_Available_Washable_andor_Dis.jpg)
Blower-less filtration housing designed with up to 4 stages of filtration for industrial applications. Designed to handle airflow between 2000 & 4000 CFM , (multiple units can be combined for greater CFM). Filter system comes standard with (2) 4” deep 30% pleated pre-filter, (2) 65% bag filter, 120ft² of media (per filter). System can be upgraded with different filter and fan packages to suit a variety of applications and contaminants.
(12-07) MS203-CV - Dusts, Mists & Gases - Multiple Filter Configurations Available / Washable and/or Disposable Filters - No Fan (3,000-6,000 CFM)
_MS203-CV_-_Dusts_Mists_&_Gases_-_Multiple_Filter_Configurations_Available_Washable_andor_Dis_948/(12-07)_MS203-CV_-_Dusts_Mists_&_Gases_-_Multiple_Filter_Configurations_Available_Washable_andor_Dis.jpg)
Blower-less filtration housing designed with up to 4 stages of filtration for industrial applications. Designed to handle airflow between 3000 & 6000 CFM , (multiple units can be combined for greater CFM). Filter system comes standard with (3) 4” deep 30% pleated pre-filter, (3) 65% bag filter, 120ft² of media (per filter). System can be upgraded with different filter and fan packages to suit a variety of applications and contaminants.
(12-09) BI Direct Drive - Self Cleaning Wheels - Inverter Duty - (1,000 - 21,000 CFM)
_BI_Direct_Drive_-_Self_Cleaning_Wheels_-_Inverter_Duty_-_(1000_-_21000_CFM)_950/(12-09)_BI_Direct_Drive_-_Self_Cleaning_Wheels_-_Inverter_Duty_-_(1000_-_21000_CFM).jpg)
Direct Drive Fans, Arr. #4 c/w punched flanged outlet and motor. Motors are TEFC E-Pact 230-460V/575-600V/3/60/-3500 RPM. Wheels are heavy gauge, single thickness, self-cleaning wheels, dynamically balanced to ANSI S2.19-1989 specifications for smooth operation. Inlet and supporting bracket accessories are also available.
NB: All Lev-Co BI fans come in a standard configuration of Clockwise rotation / Up-blast discharge. Alternate discharges can be adjusted by the installing contractor.
NB: All Lev-Co BI fans come in a standard configuration of Clockwise rotation / Up-blast discharge. Alternate discharges can be adjusted by the installing contractor.
Solutions forExhaust Fans
Exhaust Fans

(13-01) LD Direct Drive - Self Cleaning Wheels - Inverter Duty - (1,000 - 21,000 CFM)**
_LD_Direct_Drive_-_Self_Cleaning_Wheels_-_Inverter_Duty_-_(1000_-_21000_CFM)_232/(13-01)_LD_Direct_Drive_-_Self_Cleaning_Wheels_-_Inverter_Duty_-_(1000_-_21000_CFM).jpg)
Direct Drive Fans, Arr. #4 c/w punched flanged outlet, slip fit inlet, motor, motor mounting support and drain. Motors are TEFC E-Pact 230-460V/575-600V/3/60/-3500 RPM. Wheels are heavy gauge, single thickness, backward inclined, dynamically balanced to ANSI S2.19-1989 specifications for smooth operation.
NB: All Lev-Co LD fans come in a standard configuration of Clockwise rotation / Up-blast discharge. For alternate rotations and discharges, please indicate on your purchase order and approved submittal drawings
NB: All Lev-Co LD fans come in a standard configuration of Clockwise rotation / Up-blast discharge. For alternate rotations and discharges, please indicate on your purchase order and approved submittal drawings
Attachments
001 - Spec Drawings:
002 - Brochures:
003 - Case Studies:
006 - System Layouts:
007 - Written Specifications:
017 - DWG and RVT models:
(13-02) BI Belt Driven Fans (1000 – 21,000 CFM)
_BI_Belt_Driven_Fans_(1000_–_21000_CFM)_560/(13-02)_BI_Belt_Driven_Fans_(1000_–_21000_CFM).jpg)
Belt Driven Fans c/w punched flanged outlet, slip fit inlet, OSHA belt guard, v-drive, motor, motor mounting support. Motors are TEFC E-Pact 230-460V/575-600V/3/60/-3500 RPM. Wheels are heavy gauge, single thickness, backward inclined, dynamically balanced to ANSI S2.19-1989 specifications for smooth operation.
Attachments
(13-03) P-Max - Direct Mount to Arms, Hose Reels... - (200 - 2,300 CFM)**
_P-Max_-_Direct_Mount_to_Arms_Hose_Reels_-_(200_-_2300_CFM)_51/(13-03)_P-Max_-_Direct_Mount_to_Arms_Hose_Reels_-_(200_-_2300_CFM).jpg)
P-Max© "Local Exhaust" fans are recommended for applications involving fume, smoke and light dust. Suitable for direct mounting to a mounting bracket, most extraction arms, filter units, hose reels and simple hose drops.
NB: All Lev-Co P-max fans come in a standard configuration of clockwise rotation/top horizontal discharge. For alternate discharges, please indicate on your purchase order and approved submittal drawings. Alternate rotation is not available.
NB: All Lev-Co P-max fans come in a standard configuration of clockwise rotation/top horizontal discharge. For alternate discharges, please indicate on your purchase order and approved submittal drawings. Alternate rotation is not available.
Attachments
001 - Spec Drawings:
001a - Spec Drawing - Installation Examples:
002 - Brochures:
006 - System Layouts:
007 - Written Specifications:
017 - DWG and RVT models:
(13-04) Portable P-Max - Optional Hose, Nozzles... - (600 -1,500 CFM)
_Portable_P-Max_-_Optional_Hose_Nozzles_-_(600_-1500_CFM)_581/(13-04)_Portable_P-Max_-_Optional_Hose_Nozzles_-_(600_-1500_CFM).jpg)
P-Max© "Portable Local Exhaust" fans. Recommended for applications involving vehicle exhaust gases, welding fumes, smoke and light dust. An excellent portable solution where a fixed mounted system is not possible. These fans are designed specifically for "Medium Pressure" applications where the fan must be able to overcome the air resistance created when drawing contaminants through hoses.
Attachments
001 - Spec Drawings:
002 - Brochures:
017 - DWG and RVT models:
(13-05) Wall Fan - General Ventilation - Horizontal Discharge - (1,400 - 5,500 CFM)**
_Wall_Fan_-_General_Ventilation_-_Horizontal_Discharge_-_(1400_-_5500_CFM)_609/(13-05)_Wall_Fan_-_General_Ventilation_-_Horizontal_Discharge_-_(1400_-_5500_CFM).jpg)
Model LAX1V fans are sturdily constructed, direct drive, horizontal discharge for industrial, commercial and farm applications. Suitable for general ventilation of factories, garages, warehouses, and other commercial and industrial buildings.
STANDARD FEATURES: Built-in shutters that automatically open when the fan starts and gravity closes when the fan stops
heavy duty aluminum housing
Plated steel OSHA motor mount/guard
Single or variable speed operation
Aluminum fan blades on steel hub
Totally enclosed motors
STANDARD FEATURES:
Attachments
001 - Spec Drawings:
002 - Brochures:
003 - Case Studies:
006 - System Layouts:
017 - DWG and RVT models:
(13-07) Non Tempered (Neither heated or cooled) Make-Up Air - Low Cost Make Up Air - (5,000 - 30,000 CFM)
_Non_Tempered_(Neither_heated_or_cooled)_Make-Up_Air_-_Low_Cost_Make_Up_Air_-_(5000_-_30000_C_516/(13-07)_Non_Tempered_(Neither_heated_or_cooled)_Make-Up_Air_-_Low_Cost_Make_Up_Air_-_(5000_-_30000_C.jpg)
LEV-CO’s Non-Tempered Air Make-Up Systems replaces exhausted air more efficiently and with more comfort than conventional Air Make-Up air systems. Ideal for production facilities that generate heat, for example welding shops where welding processes generate up to 450,000 BTU per hour per welder.
Non-Tempered units are grouped into 2 different types:100% Outdoor Air: These units draw outside air and consist of a simple Axial fan, motorized inlet damper, Insulated cabinet and flow straightener. Modulating units – 0-100% Outdoor air: these units draw a variable amount of outside air from outside and when the internal temperature drops below the customer’s set point (EG: 70 degrees F) the THERMOSTAT controlled modulating air-mixing system allows air to be drawn from OUTSIDE or INSIDE in order to maintain desired indoor temperature. This solution is most often selected when the production level cannot be guaranteed or additional heat sources are not available.
Both solutions are aided by custom engineered flame retardant fabric distribution ducting, where we able to take advantage of the STRATIFIED heat in ceiling, creating the equivalent of lowering a conventional thermostat by ½ degree F per foot of ceiling height or provide MAKE-UP without additional heat.
This is accomplished by discharging the air in HIGH velocity air jets as close to the ceiling as possible. The result of the mixing is that the fresh air is heated to room temperature very quickly before it reaches the lower occupied area. This is extremely effective in welding shops where each welder can generate as much as 450,000 BTU per hour in heat.
This “De-Stratifying” air distribution method has the added benefit of diluting and cooling any “Fugitive emissions/smoke” in the ceiling space and allows this air to be drawn down to floor level where it can be filtered and or exhausted by local exhaust ventilation systems.
When no fresh air is needed, the system can be shut down and the outside air dampers will close automatically or the system can be run on one hundred percent (100%) re-circulated air.
Conversely, if cooling air is required, “Bi-Flex” ducting can be selected (Optional). Bi-Flex ducting allows the air to continue to be exhausted into the ceiling space in the winter months AND then be re-directed downwards to the workers in summer months. This method leaves the bulk of the hot air in the ceiling space and places high velocity cooling air towards the worker. (The velocity shall not be high enough to disturb welding gases/processes).
Non-Tempered units are grouped into 2 different types:
Both solutions are aided by custom engineered flame retardant fabric distribution ducting, where we able to take advantage of the STRATIFIED heat in ceiling, creating the equivalent of lowering a conventional thermostat by ½ degree F per foot of ceiling height or provide MAKE-UP without additional heat.
This is accomplished by discharging the air in HIGH velocity air jets as close to the ceiling as possible. The result of the mixing is that the fresh air is heated to room temperature very quickly before it reaches the lower occupied area. This is extremely effective in welding shops where each welder can generate as much as 450,000 BTU per hour in heat.
This “De-Stratifying” air distribution method has the added benefit of diluting and cooling any “Fugitive emissions/smoke” in the ceiling space and allows this air to be drawn down to floor level where it can be filtered and or exhausted by local exhaust ventilation systems.
When no fresh air is needed, the system can be shut down and the outside air dampers will close automatically or the system can be run on one hundred percent (100%) re-circulated air.
Conversely, if cooling air is required, “Bi-Flex” ducting can be selected (Optional). Bi-Flex ducting allows the air to continue to be exhausted into the ceiling space in the winter months AND then be re-directed downwards to the workers in summer months. This method leaves the bulk of the hot air in the ceiling space and places high velocity cooling air towards the worker. (The velocity shall not be high enough to disturb welding gases/processes).
Attachments
001 - Spec Drawings:
002 - Brochures:
003 - Case Studies:
006 - System Layouts:
017 - DWG and RVT models:
(13-08) Roof Fan - General Ventilation - Vertical Discharge - (2,800 - 7,000 CFM)
_Roof_Fan_-_General_Ventilation_-_Vertical_Discharge_-_(2800_-_7000_CFM)_644/(13-08)_Roof_Fan_-_General_Ventilation_-_Vertical_Discharge_-_(2800_-_7000_CFM).jpg)
Roof mounted, belt driven exhaust fan for ducted or non-ducted applications
Attachments
001 - Spec Drawings:
002 - Brochures:
006 - System Layouts:
017 - DWG and RVT models:
(13-10) DFRC-ES Series Inline Duct Fans
_DFRC-ES_Series_Inline_Duct_Fans_930/(13-10)_DFRC-ES_Series_Inline_Duct_Fans.jpg)
High efficient inline duct fans are ideal for residential and commercial ventilation applications such as range hoods, bath fans & dryers.Available in 4”, 5”, 6”, 8”, 10” and 12” diameters. Quiet and efficient backward curved impeller Powerful, efficient external rotor motor Speed controllable with Canarm MC series controls High flow against high static pressure Remove noise from main living area by mounting remotely Quick and easy installation.
(13-11) Accessories for Variable flow control system
Accessories for Variable controls systems can be complex. You will find all of the items you will need on this list to put one of these systems together yourself. For help putting together one of these systems please give us a call.
(13-12) VFD System with Manual Dampers and Speed Potentiometer - Type 1
_VFD_System_with_Manual_Dampers_and_Speed_Potentiometer_-_Type_1_871/(13-12)_VFD_System_with_Manual_Dampers_and_Speed_Potentiometer_-_Type_1.jpg)
Lev-co’s LEVEL 1 VFD system allows for simple VFD speed control, acceleration and deceleration and sound level management for all of Lev-co's exhaust and filtration solutions.
FUNCTION:The fan is activated by a small local control panel. Acceleration and deceleration settings can be programmed into the VFD in order to eliminated "Peak" demand charges and feedback from the motor. As required, the flow rate can be increased and decreased according to the demand required by the application. Additionally, great reductions in sound level can be achieved by adjust the flow The following components are included in this “Level 1” VFD solution: VFD (Variable Frequency Drive)IP55, Simple potentiometer speed control plus on/off switch and fan running indicator
FUNCTION:
Attachments
001 - Spec Drawings:
002 - Brochures:
007 - Written Specifications:
(13-13) VFD System with Manual Dampers and Pressure Transmitter - Type 2**
_VFD_System_with_Manual_Dampers_and_Pressure_Transmitter_-_Type_2_870/(13-13)_VFD_System_with_Manual_Dampers_and_Pressure_Transmitter_-_Type_2.jpg)
Lev-co’s LEVEL 2 VFD system allows for “On-Demand” flow control of an exhaust fan for industrial ventilation applications.
FUNCTION:The fan is first activated by an "Optional" switch attached to the damper, hose reel, hose drop, current sensor*, etc. When this switch closes the fan turns on. Once the damper in the 1st drop opens, a digital pressure transmitter senses the pressure in the main duct downstream of the fan and allows the VFD to actively control motor speed as a function of duct (negative) pressure. As more dampers are opened and closed the fan speed increases and decreases in order to provide the required flowrate at each drop. This permits constant, effective exhaust at a target duct pressure no matter how many dampers are open or closed. Flow "On Demand" The fan turns off when the last operator has no more demand
The following components are included in this “Level 2” VFD solution: VFD (Variable Frequency Drive)IP65 Control Panel IP65 c/w with the following components: HOA Hand/Off/Auto selector switch ”Fan on” Pilot Light Pressure Transmitter 4-20 ma Digital Pressure Gauge 1-10” WG 100’ of pneumatic tubing 1/8” MPT hose barb (for connection to duct)
FUNCTION:
The following components are included in this “Level 2” VFD solution:
Attachments
001 - Spec Drawings:
002 - Brochures:
007 - Written Specifications:
(13-14) VFD System with Powered Dampers and Pressure Transmitter - Type 3
_VFD_System_with_Powered_Dampers_and_Pressure_Transmitter_-_Type_3_872/(13-14)_VFD_System_with_Powered_Dampers_and_Pressure_Transmitter_-_Type_3.jpg)
Lev-co’s LEVEL 3 VFD system allows for “On-Demand” flow control of an exhaust fan for industrial ventilation applications.
FUNCTION:The fan is first activated by an "Optional" switch attached to the hose reel or hose drop. When this switch closes the fan turns on and opens the first motorized damper. Once the damper in the 1st drop opens, a digital pressure transmitter senses the pressure in the main duct downstream of the fan and allows the VFD to actively control motor speed as a function of duct (negative) pressure. As more dampers are opened and closed the fan speed increases and decreases in order to provide the required flowrate at each drop. This permits constant, effective exhaust at a target duct pressure no matter how many dampers are open or closed. Flow "On Demand" As each hose reel or hose drop returns to its stored position, the damper on each drop closes. The fan turns off when the last operator returns the hose to its stored/recoiled position
The following components are included in this “Level 3” VFD solution: VFD (Variable Frequency Drive) IP55 Control Panel IP55 c/w with the following components HOA Manual/Off/Auto selector switch Step-Down transformer used to supply 24 volt dampers ”Fan on” Pilot Light Pressure Transmitter 4-20 ma Pressure Gauge 1-10” WG 100’ of pneumatic tubing 1/8” MPT hose barb (for connection to duct)
FUNCTION:
The following components are included in this “Level 3” VFD solution:
Attachments
001 - Spec Drawings:
002 - Brochures:
007 - Written Specifications:
(13-75) Dust Collector Control Panel - Type 2 VFD System with shaker
_Dust_Collector_Control_Panel_-_Type_2_VFD_System_with_shaker_878/(13-75)_Dust_Collector_Control_Panel_-_Type_2_VFD_System_with_shaker.jpg)
Type 2 VFD exhaust system with shaker motor filter cleaning. Provides standard type 2 system performance (see 13-13) plus timed off-line filter cleaning with manual override. Indicators provided for fan running and filter cleaning in operation. Many standard and custom options available. Available with Invertek or ABB VFDs.
Attachments
001 - Spec Drawings:
002 - Brochures:
Solutions forVehicle Exhaust - Cars & Trucks
Vehicle Exhaust - Cars & Trucks

(14-01) Touchless -Vehicle Exhaust Extraction Arms- up to 43 feet long-600 to 1500 CFM**
_Touchless_-Vehicle_Exhaust_Extraction_Arms-_up_to_43_feet_long-600_to_1500_CFM_834/(14-01)_Touchless_-Vehicle_Exhaust_Extraction_Arms-_up_to_43_feet_long-600_to_1500_CFM.jpg)
“Ready to install and use” FLEXI Extraction Arms for vehicle exhaust and other applications. Suitable for exhaust gases applications up to 1000 degrees F. Excellent solutions for capturing and exhausting a variety of fumes, dust at source and exhausting to atmosphere. MELT PROOF - all steel construction Built in damper 1000 degree Flameproof triple-ply flexible hose Wall bracket "Stay in place" Extractor arm Optional components available such as: Exhaust Fan c/w motor overload, bird screen, backdraft damper, Exhaust duct, wall flashing and extensions hoses and hoods are available.
Attachments
001 - Spec Drawings:
001a - Spec Drawing - Installation Examples:
017 - DWG and RVT models:
(14-02) Vehicle Exhaust (Car, truck, motorcycle, Heavy equip.) Single Extractor w/ pulley kit - 4''/5”/6”/8” dia. (300/475/700/1,200 CFM)**
_Vehicle_Exhaust_(Car_truck_motorcycle_Heavy_equip)_Single_Extractor_w_pulley_kit_-_4''5”6”8”_555/(14-02)_Vehicle_Exhaust_(Car_truck_motorcycle_Heavy_equip)_Single_Extractor_w_pulley_kit_-_4''5”6”8”.jpg)
Vehicle exhaust single extractor system c/w rope, pulley kit and saddle. Available in both Low Temp. as well as High Temp Hose.Low Temp. Hose: suitable for temps. up to 250º F High Temp. Hose: suitable for temps. up to 600º F.
Attachments
001 - Spec Drawings:
001a - Spec Drawing - Installation Examples:
002 - Brochures:
017 - DWG and RVT models:
(14-03) Vehicle Exhaust (Car, truck, Heavy equip., etc.) Single Extractor w/ balancer - Hose dia.& flow rates to suit application**
_Vehicle_Exhaust_(Car_truck_Heavy_equip_etc)_Single_Extractor_w_balancer_-_Hose_dia&_flow_rat_557/(14-03)_Vehicle_Exhaust_(Car_truck_Heavy_equip_etc)_Single_Extractor_w_balancer_-_Hose_dia&_flow_rat.jpg)
Vehicle exhaust single extractor system c/w hose, balancer and saddle. Available in both Low Temp. as well as High Temp Hose.
Low Temp. Hose: suitable for temperatures up to 350º F.
High Temp. Hose: suitable for temperatures up to 850º F.
Ultra High Temp Hoses: suitable for temperatures from 750 to 2500º F.
Attachments
0001 - Installation Examples - How products go together:
001 - Spec Drawings:
001a - Spec Drawing - Installation Examples:
002 - Brochures:
003 - Case Studies:
003a - Video Case Study:
006 - System Layouts:
014 - How It Goes Together:
(14-04) Vehicle Exhaust (Car, truck, motorcycle, Heavy equip.) Hose Reel - Spring Recoil - 4''/5”/6”/8” dia. (300/475/700/1,200/2000 CFM)**
_Vehicle_Exhaust_(Car_truck_motorcycle_Heavy_equip)_Hose_Reel_-_Spring_Recoil_-_4''5”6”8”_dia_533/(14-04)_Vehicle_Exhaust_(Car_truck_motorcycle_Heavy_equip)_Hose_Reel_-_Spring_Recoil_-_4''5”6”8”_dia.jpg)
The spring recoil hose reels are designed for removing exhaust gas emitted by exhaust pipes of every type of vehicle (cars, trucks, tractors, armored vehicles and means of public transport). They are perfect for bus depots, garages or service stations. They may be mounted under a roof as well as in a wall, supporting column or at the end of an extension boom.
The hose is lowered manually against spring tension. The reel is equipped with a locking catch, which locks the reel at the required position. A further pulling of the hose releases the locking catch and then the hose reels automatically. Available in both Low Temp. as well as High Temp Hoses.
The hose is lowered manually against spring tension. The reel is equipped with a locking catch, which locks the reel at the required position. A further pulling of the hose releases the locking catch and then the hose reels automatically. Available in both Low Temp. as well as High Temp Hoses.
Attachments
001 - Spec Drawings:
001a - Spec Drawing - Installation Examples:
002 - Brochures:
003 - Case Studies:
003a - Video Case Study:
004 - Videos:
006 - System Layouts:
014 - How It Goes Together:
017 - DWG and RVT models:
(14-05) Vehicle Exhaust (Car, truck, motorcycle, Heavy equip.) Hose Reel - Motorized - 4''/5”/6”/8”/10''/12''/14" dia. (300/475/700/1,200/2000/2900/4300CFM)**
_Vehicle_Exhaust_(Car_truck_motorcycle_Heavy_equip)_Hose_Reel_-_Motorized_-_4''5”6”8”10''12''_148/(14-05)_Vehicle_Exhaust_(Car_truck_motorcycle_Heavy_equip)_Hose_Reel_-_Motorized_-_4''5”6”8”10''12''.jpg)
The electric - driven hose reels are for removing exhaust gas emitted by exhaust pipes of every type of vehicle (cars, trucks, tractors, armored vehicles). They are perfect for bus depots, garages, service stations and repair shops. One universal hose reel allows the attaching of hoses of different diameters, lengths, and temperature ratings. The Lev-co hose reel stands out due to its unique high temperature 2500 degree bearings mounted within is side plates, duct connection and supporting frame. The motor is a sealed IP 66 electric motor with back up coil and recoil handle that allows the reel to be operated when no power is available. The reel may be mounted under a roof, within a ceiling structure as well as in a wall or at the end of an extension boom. Available in both Low Temp. as well as High Temp Hose.
Low Temp. Hose: suitable for temperatures up to 250º F
High Temp. Hose: suitable for temperatures of 850º F
Ultra High temp: suitable for temperatures up to 2500 º F
NB: This reel is also an excellent solution for heavy welding, gouging, plasma and flame cutting.
NB: This reel is also an excellent solution for heavy welding, gouging, plasma and flame cutting.
Attachments
001 - Spec Drawings:
001a - Spec Drawing - Installation Examples:
002 - Brochures:
017 - DWG and RVT models:
(14-07) Vehicle Exhaust (Car, truck, motorcycle, Heavy equip.) Articulating Crane for Hoses - 4'' to 24'' dia. (300 to 18,000 CFM)
_Vehicle_Exhaust_(Car_truck_motorcycle_Heavy_equip)_Articulating_Crane_for_Hoses_-_4''_to_24'_558/(14-07)_Vehicle_Exhaust_(Car_truck_motorcycle_Heavy_equip)_Articulating_Crane_for_Hoses_-_4''_to_24'.jpg)
The VE Articulating Crane Drops allows you to position the Hose Drop on any side of the vehicle and to fold the extraction system against the wall and out of the way. The Articulating Crane will reach as far as 10m (33.5') into the service bay and pass over the top of heavy equipment with ease.
Low Temp. Hose: suitable for temperatures up to 250º F
High Temp. Hose: suitable for temperatures of 600º F
Ultra High temperatures available up to 1200º F
"Dyno" hoses for temperatures up to 2500º F
Attachments
001 - Spec Drawings:
001a - Spec Drawing - Installation Examples:
002 - Brochures:
007 - Written Specifications:
017 - DWG and RVT models:
(14-09) In-Groud In-Floor vehicle exhaust ventilation
_In-Groud_In-Floor_vehicle_exhaust_ventilation_671/(14-09)_In-Groud_In-Floor_vehicle_exhaust_ventilation.jpg)
“In-Ground” AKA “In-Floor” systems are systems that use a duct located below the floor, often embedded in concrete.
Considered “old school” by some, IN-GROUND systems will always have a place when selecting a vehicle exhaust solution.
The systems are broken down into 2 groups.Under Floor: Hose is stored in the floor and pulled out as required. On Floor: Hose is stored on a wall bracket and a “trap door” in the floor is opened and the hose is connected to the exposed inlet.
Considered “old school” by some, IN-GROUND systems will always have a place when selecting a vehicle exhaust solution.
The systems are broken down into 2 groups.
(14-11) Vehicle Exhaust Accessories (Car, truck, Heavy equip.) Hoses, Nozzles, Hose clamps, couplers, WYE’s. etc…
_Vehicle_Exhaust_Accessories_(Car_truck_Heavy_equip)_Hoses_Nozzles_Hose_clamps_couplers_WYE’s_534/(14-11)_Vehicle_Exhaust_Accessories_(Car_truck_Heavy_equip)_Hoses_Nozzles_Hose_clamps_couplers_WYE’s.jpg)
Vehicle Exhaust Accessories such as:Hoses
Tailpipe Nozzles
Hose Clamps
Overhead Stack Nozzles
Dual Tailpipe 'Y' Fittings and assemblies
Etc.
Attachments
001 - Spec Drawings:
002 - Brochures:
003a - Video Case Study:
007 - Written Specifications:
014 - How It Goes Together:
017 - DWG and RVT models:
Solutions forPortable Vehicle Exhaust
Portable Vehicle Exhaust

(14-08) Portable VES Fan (500-1500 CFM)
_Portable_VES_Fan_(500-1500_CFM)_670/(14-08)_Portable_VES_Fan_(500-1500_CFM).jpg)
For exhaust removal applications where stationary systems may not reach, the Airflow Systems V.E.S. Portable Removal System provides convenient exhaust removal for relief from the annoyance of vehicle exhaust. If not removed, vehicle exhaust can contribute to worker illness, increase facility maintenance expense, and harm the sensitive electronics of diagnostic and service equipment.
Lightweight and easy to handle, the V.E.S. Portable Removal System is a practical solution for providing exhaust removal in areas where conventional systems cannot reach.
Product Overview:Removes exhaust gases rather than just re-circulating it within the facility. One-person operation is made easy with standard wheels and support stand. Powerful 225-1000 CFM collection fan in a portable package. Operates with standard 115V power for use anywhere within a service bay.
Lightweight and easy to handle, the V.E.S. Portable Removal System is a practical solution for providing exhaust removal in areas where conventional systems cannot reach.
Product Overview:
Attachments
001 - Spec Drawings:
002 - Brochures:
Solutions forIndustrial Hose & Duct Work
Industrial Hose & Duct Work

(16-01) GPH General Duty Hose - Dust, Fume, Smoke (275°F)
_GPH_General_Duty_Hose_-_Dust_Fume_Smoke_(275°F)_694/(16-01)_GPH_General_Duty_Hose_-_Dust_Fume_Smoke_(275°F).jpg)
GPH - Lightweight TPR coated polyester fabric w/wire reinforcement. Excellent general purpose hose, somewhat more durable than TPR film hoses. Very good for low temp vehicle exhaust applications. Temp range of 60F - 275F. Price per foot. (10' Length Minimum)
Attachments
017 - DWG and RVT models:
(16-02) OM-AB-260 - Oil Mists and Abrasive dusts (260°F)
_OM-AB-260_-_Oil_Mists_and_Abrasive_dusts_(260°F)_297/(16-02)_OM-AB-260_-_Oil_Mists_and_Abrasive_dusts_(260°F).jpg)
Ideally suited for conveying oil mist from machining processes and many applications where a flexible, chemical and abrasion resistant hose is required. Wire reinforced, very flexible and clear. Minimum 5 times wear life improvement over PVC and TPR.
Attachments
001 - Spec Drawings:
007 - Written Specifications:
017 - DWG and RVT models:
(16-03) LT-300 Vehicle Exhaust Hose - Vehicle Emissions (300°F) GPH
_LT-300_Vehicle_Exhaust_Hose_-_Vehicle_Emissions_(300°F)_GPH_365/(16-03)_LT-300_Vehicle_Exhaust_Hose_-_Vehicle_Emissions_(300°F)_GPH.jpg)
This hose is well suited for low temp vehicle exhaust gases, medium duty dust collection and a variety of fume applications where external abrasion resistance is required (e.g.: dragging the hose across the floor.) Santoprene coated polyester fabric w/wire reinforcement. Spring steel wire w/ external wear strip. Temp range of – 60 F to 300 F.
Attachments
001 - Spec Drawings:
017 - DWG and RVT models:
(16-04) HRHT-850 Vehicle Exhaust - Vehicle Emissions Hose reels (850°F)
_HRHT-850_Vehicle_Exhaust_-_Vehicle_Emissions_Hose_reels_(850°F)_434/(16-04)_HRHT-850_Vehicle_Exhaust_-_Vehicle_Emissions_Hose_reels_(850°F).jpg)
Pyroflex© hose has been specifically designed for demanding high temperature “Process Ventilation” applications such a diesel exhaust and many other high temperature applications.
This hose has the following features:long Life -> Abrasion resistant both externally and internally High temperature resistance -> 850 degrees F under normal use and intermittently up to 2000 degrees F low pressure drop -> with very smooth internal bore Light weight -> easy to use and place into position fatigue resistant -> ideal for constant flexing applications such as hose reels and retraction systems.
This hose has the following features:
Attachments
001 - Spec Drawings:
007 - Written Specifications:
017 - DWG and RVT models:
(16-05) LWHT-600 Vehicle Exhaust Hose - Vehicle Emissions Light Weight (600°F) SFH1
_LWHT-600_Vehicle_Exhaust_Hose_-_Vehicle_Emissions_Light_Weight_(600°F)_SFH1_564/(16-05)_LWHT-600_Vehicle_Exhaust_Hose_-_Vehicle_Emissions_Light_Weight_(600°F)_SFH1.jpg)
Silicone Fiberglass duct suitable for high temperature 600°F vehicle exhaust control.
1 ply Silicone/Fiberglass Hose
2 plies for added service life. A popular style for stationary high temperature exhaust control applications. *Not for use with garage hose reels
1 ply Silicone/Fiberglass Hose
2 plies for added service life. A popular style for stationary high temperature exhaust control applications. *Not for use with garage hose reels
Attachments
001 - Spec Drawings:
002 - Brochures:
017 - DWG and RVT models:
(16-06) MWHT-600 Vehicle Exhaust Hose - Vehicle Emissions Medium Weight (600°F) SFH2
_MWHT-600_Vehicle_Exhaust_Hose_-_Vehicle_Emissions_Medium_Weight_(600°F)_SFH2_334/(16-06)_MWHT-600_Vehicle_Exhaust_Hose_-_Vehicle_Emissions_Medium_Weight_(600°F)_SFH2.jpg)
Material hose wall: two-layers, inner and outer layer special-coated high temperature fabric external helix: galvanized steel processesHot air Suction plants Vehicle Exhaust
Attachments
001 - Spec Drawings:
002 - Brochures:
007 - Written Specifications:
017 - DWG and RVT models:
(16-07) HWHT-600 Vehicle Exhaust Hose - Vehicle Emissions High Weight (600°F)
_HWHT-600_Vehicle_Exhaust_Hose_-_Vehicle_Emissions_High_Weight_(600°F)_676/(16-07)_HWHT-600_Vehicle_Exhaust_Hose_-_Vehicle_Emissions_High_Weight_(600°F).jpg)
Material hose wall: two-layers, inner and outer layer special-coated high temperature KEVLAR fabric external helix: galvanized steel
Processes:Hot air Suction plants Vehicle Exhaust
Processes:
Attachments
001 - Spec Drawings:
002 - Brochures:
017 - DWG and RVT models:
(16-08) HWHT-750 Hose Vehicle Exhaust Hose - Vehicle Emissions High Weight (750°F)
_HWHT-750_Hose_Vehicle_Exhaust_Hose_-_Vehicle_Emissions_High_Weight_(750°F)_336/(16-08)_HWHT-750_Hose_Vehicle_Exhaust_Hose_-_Vehicle_Emissions_High_Weight_(750°F).jpg)
MD-Master-Clip HT 750 Material hose wall: special-coated high temperature fabric, asbestos free, reinforced by woven in stainless steel wire external helix: galvanized steel processesHot air Suction plants Furnace
Attachments
001 - Spec Drawings:
002 - Brochures:
017 - DWG and RVT models:
(16-09) HWHT-1000 Vehicle Exhaust Hose - Vehicle Emissions High Weight (1000°F)
_HWHT-1000_Vehicle_Exhaust_Hose_-_Vehicle_Emissions_High_Weight_(1000°F)_337/(16-09)_HWHT-1000_Vehicle_Exhaust_Hose_-_Vehicle_Emissions_High_Weight_(1000°F).jpg)
MD-Master-Clip HT 1000 High temperature Silicon coated glass fabric asbestos free reinforced in galvanized or stainless steel wire. Excellent high temp resistance hose high flexibility can handle up to 1000 degrees. Temp range – 5° F to 1000° F. Suitable for vehicle exhaust systems; high temperature diesel exhaust. Material hose wall: special-coated high temperature fabric, asbestos free, reinforced by woven in stainless steel wire external helix: galvanized steel
Attachments
001 - Spec Drawings:
002 - Brochures:
017 - DWG and RVT models:
(16-10) - MD-Master-Clip HT 1200 (Vehicle Exhaust - 1200°F)
_-_MD-Master-Clip_HT_1200_(Vehicle_Exhaust_-_1200°F)_338/(16-10)_-_MD-Master-Clip_HT_1200_(Vehicle_Exhaust_-_1200°F).jpg)
2-layer special coated high temp fabric reinforced in stainless steel wire is the best and most widely used 1200° F range flexible hose on the market. This hose is perfect for dynos and high performance engines. Temp range – 75F to 1200°F. Price per ft. (10' Length Minimum) Material Hose Wall: two layer
Attachments
001 - Spec Drawings:
002 - Brochures:
007 - Written Specifications:
017 - DWG and RVT models:
(16-11) - MD-Master-Clip HT 1500 (Vehicle Exhaust - 1500°F)
_-_MD-Master-Clip_HT_1500_(Vehicle_Exhaust_-_1500°F)_657/(16-11)_-_MD-Master-Clip_HT_1500_(Vehicle_Exhaust_-_1500°F).jpg)
2-layer special coated high temp fabric reinforced in stainless steel wire is the best and most widely used 1500° F range flexible hose on the market. This hose is perfect for dynos and high performance engines. Temp range – 75F to 1500°F.
Price per ft. (10' Length Minimum) Material Hose Wall: two layer
Price per ft. (10' Length Minimum) Material Hose Wall: two layer
Attachments
017 - DWG and RVT models:
(16-12) - MD-Master-Clip HT 2010 (Vehicle Exhaust - 2010°F)
_-_MD-Master-Clip_HT_2010_(Vehicle_Exhaust_-_2010°F)_339/(16-12)_-_MD-Master-Clip_HT_2010_(Vehicle_Exhaust_-_2010°F).jpg)
3-layer special coated high temp fabric reinforced w/inside layer of stainless steel mesh makes this a very strong and flexible hose, excellent for high performance and massive engines- buses, trucks, jets. Price per ft. (10' Length Minimum) Material hose wall: three-layer
Attachments
001 - Spec Drawings:
002 - Brochures:
007 - Written Specifications:
017 - DWG and RVT models:
(16-20) ECH-260 - Electrically Conductive Hoses - Explosive Dusts and Vapours (260°F)
_ECH-260_-_Electrically_Conductive_Hoses_-_Explosive_Dusts_and_Vapours_(260°F)_309/(16-20)_ECH-260_-_Electrically_Conductive_Hoses_-_Explosive_Dusts_and_Vapours_(260°F).jpg)
MD-Master-Pur L-EC Material hose wall: Electrically Conductive POLYURETHANE spiral: PU-coated spring steel wire
Applications:Dangerous areas, where electrical conductivity is demanded Special hose for industrial vacuum cleaners Suction and transport of paper fibers and wood chips Transport of granules Suction and transport of abrasive materials, gaseous and liquid media Extraction of coarse-grained particles with high flow volume Oil-spray extraction Protection hose against mechanical damage
Properties: Surface resistance RO<=104 Ohm Electrically conductive Abrasion-resistant Very flexible, lightweight Small bend radius Resistant to oil and fuels, gas-tight Free of plasticisers and halogens Good chemical resistance UV- and ozone-resistant Improved pressure and vacuum characteristics High tensile and burst strength Optimum flow characteristics
Applications:
Properties:
Attachments
001 - Spec Drawings:
002 - Brochures:
007 - Written Specifications:
017 - DWG and RVT models:
(16-21) IEH-2000-HT
_IEH-2000-HT_838/(16-21)_IEH-2000-HT.jpg)
Standard 25ft length (Custom lengths available on request). Flame/water resistant, extremely flexible, 3 Ply construction, no glues or adhesives. Ideal for vehicle exhaust and high temperature fume extraction
Attachments
017 - DWG and RVT models:
(16-21) Quick Lock
_Quick_Lock_651/(16-21)_Quick_Lock.jpg)
Modular ducting systems
Attachments
001 - Spec Drawings:
002 - Brochures:
014 - How It Goes Together:
(16-25) Hose Accessories
_Hose_Accessories_548/(16-25)_Hose_Accessories.jpg)
Hose Accessories
(16-26) - Self-Supporting Fume & Dust Extraction Hose - 200°F
_-_Self-Supporting_Fume_&_Dust_Extraction_Hose_-_200°F_451/(16-26)_-_Self-Supporting_Fume_&_Dust_Extraction_Hose_-_200°F.jpg)
Fume Extractor: hose used for spot extraction of fume/dust removal. White in colour.
Priced per foot.
Priced per foot.
Attachments
001 - Spec Drawings:
017 - DWG and RVT models:
Solutions forDirect capture with hoses and nozzles
Direct capture with hoses and nozzles
(14-02) Vehicle Exhaust (Car, truck, motorcycle, Heavy equip.) Single Extractor w/ pulley kit - 4''/5”/6”/8” dia. (300/475/700/1,200 CFM)**
_Vehicle_Exhaust_(Car_truck_motorcycle_Heavy_equip)_Single_Extractor_w_pulley_kit_-_4''5”6”8”_555/(14-02)_Vehicle_Exhaust_(Car_truck_motorcycle_Heavy_equip)_Single_Extractor_w_pulley_kit_-_4''5”6”8”.jpg)
Vehicle exhaust single extractor system c/w rope, pulley kit and saddle. Available in both Low Temp. as well as High Temp Hose.Low Temp. Hose: suitable for temps. up to 250º F High Temp. Hose: suitable for temps. up to 600º F.
Attachments
001 - Spec Drawings:
001a - Spec Drawing - Installation Examples:
002 - Brochures:
017 - DWG and RVT models:
(14-03) Vehicle Exhaust (Car, truck, Heavy equip., etc.) Single Extractor w/ balancer - Hose dia.& flow rates to suit application**
_Vehicle_Exhaust_(Car_truck_Heavy_equip_etc)_Single_Extractor_w_balancer_-_Hose_dia&_flow_rat_557/(14-03)_Vehicle_Exhaust_(Car_truck_Heavy_equip_etc)_Single_Extractor_w_balancer_-_Hose_dia&_flow_rat.jpg)
Vehicle exhaust single extractor system c/w hose, balancer and saddle. Available in both Low Temp. as well as High Temp Hose.
Low Temp. Hose: suitable for temperatures up to 350º F.
High Temp. Hose: suitable for temperatures up to 850º F.
Ultra High Temp Hoses: suitable for temperatures from 750 to 2500º F.
Attachments
0001 - Installation Examples - How products go together:
001 - Spec Drawings:
001a - Spec Drawing - Installation Examples:
002 - Brochures:
003 - Case Studies:
003a - Video Case Study:
006 - System Layouts:
014 - How It Goes Together:
(14-04) Vehicle Exhaust (Car, truck, motorcycle, Heavy equip.) Hose Reel - Spring Recoil - 4''/5”/6”/8” dia. (300/475/700/1,200/2000 CFM)**
_Vehicle_Exhaust_(Car_truck_motorcycle_Heavy_equip)_Hose_Reel_-_Spring_Recoil_-_4''5”6”8”_dia_533/(14-04)_Vehicle_Exhaust_(Car_truck_motorcycle_Heavy_equip)_Hose_Reel_-_Spring_Recoil_-_4''5”6”8”_dia.jpg)
The spring recoil hose reels are designed for removing exhaust gas emitted by exhaust pipes of every type of vehicle (cars, trucks, tractors, armored vehicles and means of public transport). They are perfect for bus depots, garages or service stations. They may be mounted under a roof as well as in a wall, supporting column or at the end of an extension boom.
The hose is lowered manually against spring tension. The reel is equipped with a locking catch, which locks the reel at the required position. A further pulling of the hose releases the locking catch and then the hose reels automatically. Available in both Low Temp. as well as High Temp Hoses.
The hose is lowered manually against spring tension. The reel is equipped with a locking catch, which locks the reel at the required position. A further pulling of the hose releases the locking catch and then the hose reels automatically. Available in both Low Temp. as well as High Temp Hoses.
Attachments
001 - Spec Drawings:
001a - Spec Drawing - Installation Examples:
002 - Brochures:
003 - Case Studies:
003a - Video Case Study:
004 - Videos:
006 - System Layouts:
014 - How It Goes Together:
017 - DWG and RVT models:
(14-05) Vehicle Exhaust (Car, truck, motorcycle, Heavy equip.) Hose Reel - Motorized - 4''/5”/6”/8”/10''/12''/14" dia. (300/475/700/1,200/2000/2900/4300CFM)**
_Vehicle_Exhaust_(Car_truck_motorcycle_Heavy_equip)_Hose_Reel_-_Motorized_-_4''5”6”8”10''12''_148/(14-05)_Vehicle_Exhaust_(Car_truck_motorcycle_Heavy_equip)_Hose_Reel_-_Motorized_-_4''5”6”8”10''12''.jpg)
The electric - driven hose reels are for removing exhaust gas emitted by exhaust pipes of every type of vehicle (cars, trucks, tractors, armored vehicles). They are perfect for bus depots, garages, service stations and repair shops. One universal hose reel allows the attaching of hoses of different diameters, lengths, and temperature ratings. The Lev-co hose reel stands out due to its unique high temperature 2500 degree bearings mounted within is side plates, duct connection and supporting frame. The motor is a sealed IP 66 electric motor with back up coil and recoil handle that allows the reel to be operated when no power is available. The reel may be mounted under a roof, within a ceiling structure as well as in a wall or at the end of an extension boom. Available in both Low Temp. as well as High Temp Hose.
Low Temp. Hose: suitable for temperatures up to 250º F
High Temp. Hose: suitable for temperatures of 850º F
Ultra High temp: suitable for temperatures up to 2500 º F
NB: This reel is also an excellent solution for heavy welding, gouging, plasma and flame cutting.
NB: This reel is also an excellent solution for heavy welding, gouging, plasma and flame cutting.
Attachments
001 - Spec Drawings:
001a - Spec Drawing - Installation Examples:
002 - Brochures:
017 - DWG and RVT models:
(14-06) Vehicle Exhaust (Car, truck, motorcycle, Heavy equip.) Extension Booms - (Up to 24” Ø and 24,000 CFM)
_Vehicle_Exhaust_(Car_truck_motorcycle_Heavy_equip)_Extension_Booms_-_(Up_to_24”_Ø_and_24000__447/(14-06)_Vehicle_Exhaust_(Car_truck_motorcycle_Heavy_equip)_Extension_Booms_-_(Up_to_24”_Ø_and_24000_.jpg)
The Extension Boom allows to install the hose reel or hose drop the end of a 2m (6.5'), 3m (10') or 4m (13') extension boom. This allows positioning the hose drop on any side of the vehicle, and also allows the extraction system to be folded against the wall and out of the way.
Attachments
001 - Spec Drawings:
- (14-06-01) VE Extension Boom for HR - SD.pdf
- (14-06-02) VE Extension Boom for HR+Hose Reel+P-Max Fan .pdf
- (14-06-03) VE Extension Boom for HR +Hose Reel.pdf
- (14-06-04) VE Extension Boom for Hose Drops SD.pdf
- (14-06-05) VE Extension Boom for Hose Drops+ Hose Drop.pdf
- (14-06-06) VE Extension Crane + Hose Drop+P-MAx Fan.pdf
002 - Brochures:
003 - Case Studies:
003a - Video Case Study:
(14-07) Vehicle Exhaust (Car, truck, motorcycle, Heavy equip.) Articulating Crane for Hoses - 4'' to 24'' dia. (300 to 18,000 CFM)
_Vehicle_Exhaust_(Car_truck_motorcycle_Heavy_equip)_Articulating_Crane_for_Hoses_-_4''_to_24'_558/(14-07)_Vehicle_Exhaust_(Car_truck_motorcycle_Heavy_equip)_Articulating_Crane_for_Hoses_-_4''_to_24'.jpg)
The VE Articulating Crane Drops allows you to position the Hose Drop on any side of the vehicle and to fold the extraction system against the wall and out of the way. The Articulating Crane will reach as far as 10m (33.5') into the service bay and pass over the top of heavy equipment with ease.
Low Temp. Hose: suitable for temperatures up to 250º F
High Temp. Hose: suitable for temperatures of 600º F
Ultra High temperatures available up to 1200º F
"Dyno" hoses for temperatures up to 2500º F
Attachments
001 - Spec Drawings:
001a - Spec Drawing - Installation Examples:
002 - Brochures:
007 - Written Specifications:
017 - DWG and RVT models:
(14-08) Portable VES Fan (500-1500 CFM)
_Portable_VES_Fan_(500-1500_CFM)_670/(14-08)_Portable_VES_Fan_(500-1500_CFM).jpg)
For exhaust removal applications where stationary systems may not reach, the Airflow Systems V.E.S. Portable Removal System provides convenient exhaust removal for relief from the annoyance of vehicle exhaust. If not removed, vehicle exhaust can contribute to worker illness, increase facility maintenance expense, and harm the sensitive electronics of diagnostic and service equipment.
Lightweight and easy to handle, the V.E.S. Portable Removal System is a practical solution for providing exhaust removal in areas where conventional systems cannot reach.
Product Overview:Removes exhaust gases rather than just re-circulating it within the facility. One-person operation is made easy with standard wheels and support stand. Powerful 225-1000 CFM collection fan in a portable package. Operates with standard 115V power for use anywhere within a service bay.
Lightweight and easy to handle, the V.E.S. Portable Removal System is a practical solution for providing exhaust removal in areas where conventional systems cannot reach.
Product Overview:
Attachments
001 - Spec Drawings:
002 - Brochures:
(14-09) In-Groud In-Floor vehicle exhaust ventilation
_In-Groud_In-Floor_vehicle_exhaust_ventilation_671/(14-09)_In-Groud_In-Floor_vehicle_exhaust_ventilation.jpg)
“In-Ground” AKA “In-Floor” systems are systems that use a duct located below the floor, often embedded in concrete.
Considered “old school” by some, IN-GROUND systems will always have a place when selecting a vehicle exhaust solution.
The systems are broken down into 2 groups.Under Floor: Hose is stored in the floor and pulled out as required. On Floor: Hose is stored on a wall bracket and a “trap door” in the floor is opened and the hose is connected to the exposed inlet.
Considered “old school” by some, IN-GROUND systems will always have a place when selecting a vehicle exhaust solution.
The systems are broken down into 2 groups.
(14-10) Vehicle Exhaust Rails
_Vehicle_Exhaust_Rails_672/(14-10)_Vehicle_Exhaust_Rails.jpg)
Our rail systems serve mobilize source capture devices and transport of contaminated fumes safely away from the working environment. These rails can be used for a variety of applications. Additionally, they can simple Hose drops with balancers (As shown in the image to the right) or more ergonomic by adding a hose reel and more 'user friendly' by adding an extractor arm. The working range of the systems is determined by the length of the rails and capture devices. Future expansion is a breeze, by simply adding extra rail, trolleys and or capture devices.
(14-11) Vehicle Exhaust Accessories (Car, truck, Heavy equip.) Hoses, Nozzles, Hose clamps, couplers, WYE’s. etc…
_Vehicle_Exhaust_Accessories_(Car_truck_Heavy_equip)_Hoses_Nozzles_Hose_clamps_couplers_WYE’s_534/(14-11)_Vehicle_Exhaust_Accessories_(Car_truck_Heavy_equip)_Hoses_Nozzles_Hose_clamps_couplers_WYE’s.jpg)
Vehicle Exhaust Accessories such as:Hoses
Tailpipe Nozzles
Hose Clamps
Overhead Stack Nozzles
Dual Tailpipe 'Y' Fittings and assemblies
Etc.
Attachments
001 - Spec Drawings:
002 - Brochures:
003a - Video Case Study:
007 - Written Specifications:
014 - How It Goes Together:
017 - DWG and RVT models: