Main System / Part |
Part # |
Qty |
Description |
DC-12 |
|
Cartridge dust collector with (12) Clean 2® filters, front load, 5 HP motor/blower with AMCA Type B spark resistant blower wheel, and auto clean Vibra-Pulse® cleaning system with ½” regulator. Motor starters not included |
Filter Options (when ordering with main unit) |
Part # |
Qty |
Description |
DC-12-EXT-AD4 |
|
External AD-4000 CFM (Includes Silencer) Option for Standard DC-12 Unit |
DC-12-EXT-HE4 |
|
External Hepa-6000 CFM (Includes Silencer) Option for Standard DC-12 Unit.(Includes S-BI silencer option.) |
DC-12-FD |
|
FiberDust Cartridge Filter Option for Standard DC-12 Unit |
DC-12-UCP |
|
ULTRACLEAN-PLUS Cartridges Option for Standard DC-12 Unit |
Fan Control Panels (when ordering main unit) |
Part # |
Qty |
Description |
P-025-120S-120V-1PH-2.0 HP |
|
Energy Saver E- Man© 115V/1/60. Fan Motor control station. Rated up to 2 HP. Permits start-stop of the fan / Dustcollector from a Remote Switch/control. Remote mounted switches must be ordered separately but it is best to interlock the fan with the associate process. Comes complete with relevant Motor overload. Please specify Motor HP when ordering ______.Also includes a 50 VA 120V AC transformer for powering the dust collectors sequencer. |
P-025-120S-208/230V-3PH-7.5 HP |
|
Energy Saver E- Man© 208-230V/3/60. Fan Motor control station. Rated up to 7.5 HP. Permits start-stop of the fan / Dustcollector from a Remote Switch/control. Remote mounted switches must be ordered separately but it is best to interlock the fan with the associate process. Comes complete with relevant Motor overload. Please specify Motor HP when ordering ______.Also includes a 50 VA 120V AC transformer for powering the dust collectors sequencer. |
P-025-120S-240V-1PH-3HP |
|
Energy Saver E- Man© 240V/1/60. Fan Motor control station. Rated up to 3 HP. Permits start-stop of the fan / Dustcollector from a Remote Switch/control. Remote mounted switches must be ordered separately but it is best to interlock the fan with the associate process. Comes complete with relevant Motor overload. Please specify Motor HP when ordering ______.Also includes a 50 VA 120V AC transformer for powering the dust collectors sequencer. |
P-025-120S-460V-3PH-20HP |
|
Energy Saver E- Man© 460V/3/60. Fan Motor control station. Rated up to 20 HP. HP. Permits start-stop of the fan / Dustcollector from a Remote Switch/control. Remote mounted switches must be ordered separately but it is best to interlock the fan with the associate process. Comes complete with relevant Motor overload. Please specify Motor HP when ordering ______.Also includes a 50 VA 120V AC transformer for powering the dust collectors sequencer. |
Starter-MNT |
|
Kit for mounting Magnetic or Manual starters for T-140 |
Sound Attenuation |
Part # |
Qty |
Description |
DC-12-S-BI |
|
5HP, 7.5HP & 10HP BI Blower Silencer Option for Standard DC-12 Unit |
Misc. Options |
Part # |
Qty |
Description |
DC-12-BLOCK OFF |
|
Block Off Components Option for Standard DC-12 Unit |
DC-12-EXP VENT |
|
Explosion Vent Door Option for Standard DC-12 Unit |
DC-12-HOPPER-20 |
|
20 Gal. Hopper Option for Standard DC-12 Unit |
DRUM-45 |
|
45 imperial gallon (55 US gallons) steel drum c/w lid. |
Misc. Options (when ordering main unit) |
Part # |
Qty |
Description |
EXP VENT-DC12 |
|
Explosion vent for DC12 Unit |
EXP VENT-DC4/6/8 |
|
Explosion vent for DC 4/6 or 8 unit |
Energy Saving Options (Automatic Dampers, Timers, VFD's...) |
Part # |
Qty |
Description |
P-025-120S-575V-3PH-20HP |
|
Energy Saver E- Man© 575V/3/60. Fan Motor control station. Rated up to 20 HP. HP. Permits start-stop of the fan / Dustcollector from a Remote Switch/control. Remote mounted switches must be ordered separately but it is best to interlock the fan with the associate process. Comes complete with relevant Motor overload. Please specify Motor HP when ordering ______.Also includes a 50 VA 120V AC transformer for powering the dust collectors sequencer. |
Preventative Maintenance Pressure Gauges, etc. (when ordering main unit) |
Part # |
Qty |
Description |
DC-12-PG-10 |
|
0-10 magna-helic pressure gauge, approximately 5 diameter size. Surface mounted. |
LEV-MC-PG-5 |
|
Pressure Gauge - complete with Wall, Ceiling or table mounting bracket and 0-5 pressure gauge. 3/16 inside diameter tubing ordered separately. |
PG-10 |
|
Pressure Gauge - complete with Wall, Ceiling or table mounting bracket and 0-10 pressure gauge. 3/16 inside diameter tubing ordered separately. |
- Installation Accessories |
Part # |
Qty |
Description |
DC-12-GATE |
|
Slide Gate Option for Standard DC-12 Unit |
DC-12-RS |
|
Rain Shield Kit Option for Standard DC-12 Unit |
Replacement filters - (Quantity discounts available upon request) |
Part # |
Qty |
Description |
7FH9-9112 |
|
99.97% HEPA Filter, wood fram |
7FR0-2020 |
|
Flame Retardant Cartridge Filter made of 80/20% Cell/Poly Blend,. Replacement Filter for DCH/PCH/DTH, TC-4, HC-4, DC-4/6/8/12/18 & DT-3000V2 filter units.
Complete with Vibra Pulse Tube
|
7FR0-2020 - PTFE |
|
Cartridge filter PTFE Polyester media for PCH/DCH/DTH units |
7FR0-2020-OEM |
|
Replacement Filter |
7FR0-2021-1 |
|
Cartridge for PCH-1, PCH-2, DCH-1, DCH-2, DC-4, DC-6, DC-8, DC-12, DTH-800, DTH-1700 and DT3000v2.0.
Base Filter |
7FR0-2027 |
|
Teflon Filter for DCH/PCH/DTH, TC-4, HC-4, DC-4/6/8/12/18 & DT-3000V2 filter units.
VIBRA-PULSE tubes included |
7FR0-5020 |
|
OEM Cartridge Filter ALH-1/2/6 filter used in explosive and flamable applications such as aluminum dust applications. |
CHARCOAL-10 |
|
10 lbs. Bag of non-recycled coconut shell-based, activated carbon.
|
CHARCOAL-15 |
|
15 lbs. Bag of non-recycled coconut shell-based activated carbon.
|
CHARCOAL-200 |
|
200 lbs. of non-recycled coconut shell-based activated charcoal
|
CHARCOAL-5 |
|
5 lbs. of non-recycled coconut shell-based activated charcoal. |
CS-350-999 |
|
CLEAR SKY SERIES Nano Fiber Filters. Flame Retardant with nano fiber technology. Replacement Filter for DCH/PCH/DTH, TC-4, HC-4, DC-4/6/8/12/18 & DT-3000V2 filter units.
Complete with Vibra Pulse Tube
|
Spare Part (Call for quantity discount) |
Part # |
Qty |
Description |
7EG3-1015 |
|
Vibra Pulse Board for DC12 Unit |