model_icon
(13-01) LD Direct Drive - Self Cleaning Wheels - Inverter Duty - (1,000 - 21,000 CFM)**
Direct Drive Fans, Arr. #4 complete with punched flanged outlet, slip fit inlet, motor, motor mounting support and drain. Motors are TEFC E-Pact 230-460V/575-600V/3/60/-3500 RPM. Wheels are heavy gauge, single thickness, backward inclined, dynamically balanced to ANSI S2.19-1989 specifications for smooth operation.
NB: All Lev-Co LD fans come in a standard configuration of Clockwise rotation / Up-blast discharge. For alternate rotations and discharges, please indicate on your purchase order and approved submittal drawings CONSTRUCTION:

Solidly built with continuously welded housings and mounting holes in all support flanges. All fans are mechanically run tested prior to shipment to ensure the balance of the assembled unit.
Main System / Part
Part # Description
LD-130-1 2000 CFM@10 w.g. to 3000 CFM@5 w.g. BI Direct Drive Fan c/w slip fit inlet, flanged outlet; Class II c/w, 5 HP, 115-230V/3/60, 3600 RPM.
LD-220-2 10,000 CFM @ 18" SP AT 3500 RPM Backward Inclined Blower, ARR. #4, Class IV, Direct Drive c/w:
  • Steel Housing
  • 70% Width Type 'HD' Wheel
  • AMCA Type 'C' Spark Resistance Construction
  • Slip Fit Inlet
  • Flanged Discharge
  • Quick Open Inspection Door
  • Drain
  • 40 HP 3/60/575V 3500 RPM TEFC Motor Suitable for VFD
  • LD-120-2 1300 CFM @ 9 w.g. to 2000 CFM@5 w.g. BI Direct Drive Fan c/w slip fit inlet, flanged outlet; Class II c/w, 3 HP, 230-460V/3/60, 3600 RPM.
    LD-120-3 1300 CFM @ 9 w.g. to 2000 CFM @ 5 w.g. BI Direct Drive Fan c/w slip fit inlet, flanged outlet; Class II c/w 3 HP 575V/3/60, 3600 RPM.
    LD-130-2 2000 CFM@10 w.g. to 3000 CFM@5 w.g. BI Direct Drive Fan c/w slip fit inlet, flanged outlet; Class II c/w, 5 HP, 230-460V/3/60, 3600 RPM.
    LD-130-3 2000 CFM@10 w.g. to 3000 CFM@5 w.g. BI Direct Drive Fan c/w slip fit inlet, flanged outlet; Class II c/w, 5 HP, 575-600V/3/60, 3600 RPM.
    LD-150-2 3000 CFM@9 w.g. to 4500 CFM@5 w.g. BI Direct Drive Fan c/w slip fit inlet, flanged outlet; Class II c/w 7.5 HP, 230-460V/3/60, 3600 RPM.
    LD-150-3 3000 CFM@9 w.g. to 4500 CFM@5 w.g. BI Direct Drive Fan c/w slip fit inlet, flanged outlet; Class II c/w 7.5 HP, 575V/3/60, 3600 RPM.
    LD-160-2 4000 CFM@10 w.g. to 5000 CFM@6 w.g. BI Direct Drive Fan c/w slip fit inlet, flanged outlet; Class IV c/w 10 HP/3 PH, 230-460V/3/60, 3600 RPM.
    LD-160-3 4000 CFM@10" w.g. to 5000 CFM@6 w.g. BI Direct Drive Fan c/w slip fit inlet, flanged outlet; Class IV c/w 10 HP/3 PH, 230-460-575-600V/3/60, 3600 RPM.
    LD-180-1 5000 CFM@12" w.g. to 7000 CFM@4 w.g. BI Direct Drive Fan c/w slip fit inlet, flanged outlet; Class IV c/w 15 HP/3 HP, 230-460V/3/60, 3600 RPM.
    LD-180-2 5000 CFM@12w.g. to 7000 CFM@4 w.g. BI Direct Drive Fan c/w slip fit inlet, flanged outlet; Class IV c/w 15 HP/3 HP, 575V/3/60, 3600 RPM.
    LD-180-3 8000 CFM@9 w.g. to 9,500 CFM@6 w.g. BI Direct Drive Fan c/w slip fit inlet, flanged outlet; Class IV c/w 20 HP/ 3 HP, 230-460V/3/60, 3600 RPM.
    LD-180-4 8000 CFM@9 w.g. to 9,500 CFM@6 w.g. BI Direct Drive Fan c/w slip fit inlet, flanged outlet; Class IV c/w 20 HP/3 PH, 575/3/60, 3600 RPM.
    LD-240-2 10,000 CFM@7.5" w.g. to 12,000 CFM@5.5 w.g. BI Direct Drive Fan c/w slip fit inlet, flanged outlet; Class IV c/w 20 HP/3 HP, 230-460V/3/60, 1750 RPM.
    LD-240-3 10,000 CFM@7.5 w.g. to 12,000 CFM@5.5 w.g. BI Direct Drive Fan c/w slip fit inlet, flanged outlet; Class IV c/w 20 HP, 575/3/60, 1750 RPM.
    LD-270-2 12,000 CFM@8" w.g. to 14,500 CFM@5.5 w.g. BI Direct Drive Fan c/w slip fit inlet, flanged outlet; Class IV c/w 25 HP/3 HP, 230/460/3/60, 1750 RPM.
    LD-270-3 12,000 CFM@8" w.g. to 14,500 CFM@5.5 w.g. BI Direct Drive Fan c/w slip fit inlet, flanged outlet; Class IV c/w 25 HP/ 3 HP, 575V/3/60, 1750 RPM.
    LD-271-2 14,000 CFM@8 w.g. to 17,000 CFM@5.5 w.g. BI Direct Drive Fan c/w slip fit inlet, flanged outlet; Class IV c/w 30 HP 230/460/3/60, 1750 RPM.
    LD-271-3 14,000 CFM@8 w.g. to 17,000 CFM@5.5 w.g. BI Direct Drive Fan c/w slip fit inlet, flanged outlet; Class IV c/w 30 HP 575V/3/60, 1750 RPM.
    Explosion Proof Option (when ordering main unit)
    Part # Description
    BI-120-2-EXP Explosion proof motor Option for BI-120 fans. Class 1 Division 2.
    LD-130-1-EXP Explosion proof motor 5 HP 575V/3/60, 3600 RPM for LD-120.
  • Class I Div. II
  • Start/Stop Switch
    Part # Description
    P-025-RELAY Relay switches for panel. This was originally called '420MPL044C' when it was added as a custom product by the sales rep.
    Fan Control Panels (when ordering main unit)
    Part # Description
    P-024-10 Fan Motor control station. Permits manual start-stop of the fan. Comes complete with motor overload protection, field assembly required. 20-25A OVERLOAD---> HP rating: 2.0@115/1/60, 3.0@230/1/60, 7.5@208/3/60, 7.5@230/3/60, 15@460/3/60, 20@575/3/60
    P-024-11 Fan Motor control station. Permits manual start-stop of the fan. Comes complete with motor overload protection, field assembly required. 25-32A OVERLOAD---> HP rating: 2.0@115/1/60, 5@230/1/60, 10@208/3/60, 10@230/3/60, 20@460/3/60, 30@575/3/60
    P-024-3 Fan Motor control station. Permits manual start-stop of the fan. Comes complete with motor overload protection and on/off control. 1-1.6A OVERLOAD ---> HP rating: 1/3@230/3/60. 3/4@460/3/60, 1.0@575/3/60
    P-024-4 Fan Motor control station. Permits manual start-stop of the fan. Comes complete with motor overload protection and on/off control. 1.6-2.5A OVERLOAD ---> HP rating: 1/2@230/3/60, 1.0@460/3/60, 1.5@575/3/60
    P-024-5 Fan Motor control station. Permits manual start-stop of the fan. Comes complete with motor overload protection and on/off control. 2.5-4A OVERLOAD---> HP rating: 3/4@230/3/60, 2.0@460/3/60, 3.0@575/3/60
    P-024-6 Fan Motor control station. Permits manual start-stop of the fan. Comes complete with motor overload protection and on/off control. 4.0-6.3A OVERLOAD---> HP rating: 0.25@115/1/60, 0.5@230/1/60, 1.5@230/3/60, 3/0@460/3/60, 5.0@575/3/60 Price update Jan 30 2010 TC
    P-024-7 Fan Motor control station. Permits manual start-stop of the fan. Comes complete with motor overload protection and on/off control. 6.3-10A OVERLOAD---> HP rating: 1/2@115/1/60, 1.5@230/1/60, 2@208/3/60, 3.0@230/3/60, 5@460/3/60, 7.5@575/3/60
    P-024-9 Fan Motor control station. Permits manual start-stop of the fan. Comes complete with motor overload protection and on/off control. 16-20A OVERLOAD---> HP rating: 1.5@115/1/60, 3@230/1/60, 5@208/3/60, 5@230/3/60, 10@460/3/60, 15@575/3/60
    Spark Resistant Option for SQBI fans
    Part # Description
    LD-120-B AMCA Type B spark resistant construction option for LD-120-1 & LD-120-2
    LD-120-C AMCA Type C spark resistant construction option for LD-120-1 & LD-120-2
    LD-130-B AMCA Type B spark resistant construction option for LD-130-1 & LD-130-2 fans.
    LD-130-C AMCA Type C spark resistant construction option for LD-130-1 & LD-130-2 fans.
    LD-150-B AMCA Type B spark resistant construction option for LD-150-1 & LD-150-2 fans.
    LD-150-C AMCA Type C spark resistant construction option for LD-150-1 & LD-150-2 fans.
    LD-160-B AMCA Type B spark resistant construction option for LD-160-1 & LD-160-2 fans.
    LD-160-C AMCA Type C spark resistant construction option for LD-160-1 & LD-160-2 fans.
    LD-180-B AMCA Type B spark resistant construction option for LD-180-1; LD-180-2; LD-180-3; LD-180-4 fans.
    LD-180-C AMCA Type C spark resistant construction option for LD-180-1; LD-180-2; LD-180-3; LD-180-4 fans.
    LD-240-B AMCA Type B spark resistant construction option for LD-240-1 & LD-240-2 fans.
    LD-240-C AMCA Type C spark resistant construction option for LD-240-1 & LD-240-2 fans.
    LD-270-B AMCA Type B spark resistant construction option for LD-270-1, LD-270-2, LD-270-3, LD-270-4 fans.
    LD-270-C AMCA Type C spark resistant construction option for LD-270-1, LD-270-2, LD-270-3, LD-270-4 fans.
    “Epoxy” Coating for SQBI fans (when ordering main unit)
    Part # Description
    LD-120-E Epoxy option for LD-120-1 & LD-120-2 fans. The epoxy paint is Sherwin Williams, heat cured, for entire fan inside and outside.
    LD-130-E Epoxi option for LD-130-1 & LD-130-2 fans. The epoxy paint is Sherwin Williams, heat cured, for entire fan inside and outside
    LD-150-E Epoxi option for LD-150-1 & LD-150-2 fans. The epoxy paint is Sherwin Williams, heat cured, for entire fan inside and outside
    LD-160-E Epoxi option for LD-160-1 & LD-160-2 fans. The epoxy paint is Sherwin Williams, heat cured, for entire fan inside and outside
    LD-180-E Epoxi option for LD-180-1; LD-180-2; LD-180-3; LD-180-4 fans. The epoxy paint is Sherwin Williams, heat cured, for entire fan inside and outside
    Manual Motor Starter
    Part # Description
    P-024-2 Fan Motor control station. Permits manual start-stop of the fan. Comes complete with motor overload protection and on/off control. 0.63-1.0A OVERLOAD---> HP rating: 1/2@460/3/60, 1/2@575/3/60
    P-024-8 Fan Motor control station. Permits manual start-stop of the fan. Comes complete with motor overload protection and on/off control. 10-16A OVERLOAD---> HP rating: 1.0@115/1/60, 2.0@230/1/60, 3.0@208/3/60, 5.0@230/3/60, 10@460/3/60, 10@575/3/60V
    Automatic Motor Starter
    Part # Description
    P-025-24S-230V-1PH-0.5HP Energy Saver E- Man© 230V/1/60. Fan Motor control station for 0.5 HP. Permits automatic start-stop of the fan from the extractor arm hood, hose reel or other device with Remote Switch. Remote mounted switches must be ordered separately (EG: LS-12 - Hood mounted Switch, MS-12 Hose reels...). Comes complete with relevant Motor overload. Also includes a 50 VA 24V AC transformer for powering devices such as halogen Lights.
    P-025-24S-460V-3PH-20HP Energy Saver E- Man© 460V/3/60. Fan Motor control station. Rated up to 20 HP. Permits automatic start-stop of the fan from the extractor arm hood, hose reel or other device with Remote Switch. Remote mounted switches must be ordered separately (EG: LS-12 - Hood mounted Switch, MS-12 Hose reels...). Comes complete with relevant Motor overload. Please specify Motor HP when ordering ______. Also includes a 50 VA 24V AC transformer for powering devices such as halogen Lights.
    P-025-24S-575V-3PH-20HP Energy Saver E- Man© 575V/3/60. Fan Motor control station. Rated up to 20 HP. Permits automatic start-stop of the fan from the extractor arm hood, hose reel or other device with Remote Switch. Remote mounted switches must be ordered separately (EG: LS-12 - Hood mounted Switch, MS-12 Hose reels...). Comes complete with relevant Motor overload. Also includes a 50 VA 24V AC transformer for powering devices such as halogen Lights.
    Fan, Light & Other Electrical Accessories
    Part # Description
    3AB8-1701 KIT, BLWR WHL RPLCMNT, PWR BTH, 5HP, PLSTC TO ALUM Aluminum blower wheel w/ bushing, a new Inlet cone and hardware
    Misc. Options
    Part # Description
    LD-130-SIL Discharge silencer for LD-130 Fans, 15 dBA noise reduction, flanged both sides
    LD-150-SIL Discharge silencer for LD-150 Fans, 15 dBA noise reduction, flanged both sides
    LD-160-SIL Discharge silencer for LD-160 Fans, 15 dBA noise reduction, flanged both sides
    LD-180-1&2-SIL Discharge silencer for LD-180 1&2 Fans, 15 dBA noise reduction, flanged both sides
    Misc. Options (when ordering main unit)
    Part # Description
    LD-120-SIL Discharge silencer for LD-120 Fans, 15 dBA noise reduction, flanged both sides
    VFD-575V-25 Variable Frequency drive for 25HP 575/3/60Hz motor
    Accessories for direct drive and belt driven fans
    Part # Description
    ACCESS-DOOR Quick open Door, optional accessory for Lev-co fans.
    BI-ACC-DOOR Quick open access/inspection door for BI fans
    DISC-MRD403P Motor Disc Rotary Encl 40A 3P N4-IP65
    BI-135-CONE-AL BI-135 Inlet cone, Alumiunm, for 75% width impeller
    BI-DRAIN Drain, optional accessory for BI Fans, 1/2" Push in connection. Installed on site, step drill bit included with kit. To be installed at the lowest point on the fan.
    BI-RIS-1 RIS isolators 2X2 with rails.
    FR-Pressure-Transmitter Differential pressure transmitter 4-20 mA output, selectable range 25'' w.c. (5kPa), panel mount, with LCD
    LD-130-DRAIN Drain, Optional accessorie for LD-130 Fans (LD-130-1 & LD-130-2)
    LD-150-DRAIN Drain, optional accessory for LD-150-1 & LD-150-2 fans.
    LD-160-DRAIN Drain, Optional accessorie for LD-160 Fans(LD-160-1 & LD-160-2).
    LD-180-DRAIN Drain, Optional accessorie for LD-180 Fans(LD-180-1 & LD-180-2, LD-180-3 & LD-180-4)
    LD-240-DRAIN Drain, Optional accessorie for LD-240 Fans(LD-240-1 & LD-240-2).
    LD-270-DRAIN Drain, Optional accessorie for LD-270 Fans(LD-270-1, LD-270-2, LD-270-3 LD-270-4).
    L-QOD-1 Quick open door option for LD-120 ---> LD-160
    L-QOD-2 Quick open door option for LD-180, LD-200, LD-220
    L-QOD-3 Quick open door option for LD-240, LD-270
    L-RIS-2 RIS isolators with rails option for LD-240, LD-270, LB-200, LB-220
    Energy Saving Options (Automatic Dampers, Timers, VFD's...)
    Part # Description
    P-025-24S-230V-3PH-7.5 HP Energy Saver E- Man© 230V/3/60. Fan Motor control station for 7.5 HP. Permits automatic start-stop of the fan from the extractor arm hood, hose reel or other device with Remote Switch. Remote mounted switches must be ordered separately (EG: LS-12 - Hood mounted Switch, MS-12 Hose reels...). Comes complete with relevant Motor overload. Also includes a 50 VA 24V AC transformer for powering devices such as halogen Lights.
    P-025-24S-575V-3PH-30HP Energy Saver E- Man© 575V/3/60. Fan Motor control station. Panel Mounted "Hand/Off/Auto" switch and Pilot light. Rated up to 30 HP. Permits automatic start-stop of the fan from the extractor arm hood, hose reel or other device with Remote Switch. Remote mounted switches must be ordered separately #EG: LS-12 - Hood mounted Switch, MS-12 Hose reels...#. Comes complete with relevant Motor overload. Please specify Motor HP when ordering ______. Also includes a 50 VA 24V AC transformer for powering devices such as halogen Lights.
    Hazardous location certifications and accessories
    Part # Description
    HAZLOC-CERT-EXISTING-EQUIP Hazardous Location Certification for equipment use in Class 1 Division 2. To include but not limited to the following:

    Hazardous location equipment Labeling

  • Approval Report
  • Certification Sticker
  • USED FOR AN EXISTING IDENTICAL UNIT THAT HAS ALREADY BEEN CERTIFIED BY LABTEST.
  • HAZLOC-CERT-NEW-EQUIPMENT Hazardous Location Certification for equipment use in Class 1 Division 2. To include but not limited to the following:

    Hazardous location equipment Labeling

  • Approval Report
  • Certification Sticker
  • Preventative Maintenance Pressure Gauges, etc. (when ordering main unit)
    Part # Description
    PG-10 Pressure Gauge - complete with Wall, Ceiling or table mounting bracket and 0-10 pressure gauge. 3/16 inside diameter tubing ordered separately.
    - Installation Accessories
    Part # Description
    Bird Screen-CAP-12 Bird screen cap, attaches to the end of a duct segment.
    Vibration Isolator Vibration Isolation for fans
    Vibration Isolator-Rubber Vibration Isolator Rubber
     
    Other Industries / Processes
    As we understand that our products may need to be re-applied during their life span (+20 years), we have listed below other applications that this product can be used For. Before re-applying any of our solutions, please contact one of our representatives to confirm the suitability of your application.

    Chemicals and Plastics Manufacturing - Resin Manufacturing
    Chemicals and Plastics Manufacturing - Rubber Manufacturing
    Chemicals and Plastics Manufacturing - Soap Manufacturing
    Construction - Concrete Demolition Hammer
    Educational Facilities - Auto Shop
    Educational Facilities - Welding Shop
    Food & Beverage Manufacturing - Canning
    Food & Beverage Manufacturing - Food Packaging Plant
    Food & Beverage Manufacturing - Fruit Production
    Food & Beverage Manufacturing - Refrigeration
    Forensics - Forensics Laboratories
    Heavy and Farm Equipment Repair - Farm Equipment Repair
    Heavy and Farm Equipment Repair - Heavy Equipment Repair
    Machine Shop - Straight Line Automatic Buffing
    Marine - Hull Building
    Mining and Quarrying - Drilling
    Mining and Quarrying - Lead Smelting
    Mining and Quarrying - Nickel Mining
    Miscellaneous Operations - Cigarette and Tobacco Smoke
    Miscellaneous Operations - Mortuary Table
    MRO - Diesel Engines Repair
    MRO - Heavy Equipment Repair
    MRO - Steel Welding
    Museums, Historical Sites, and Similar Institutions - Artifact Cleaning
    Museums, Historical Sites, and Similar Institutions - Paleontology
    National Defense - Military Vehicle Repair
    Painting - Dip Tank
    Painting - Drying Oven Ventilation
    Painting - Large Paint Booth
    Painting - Paint Mix Storage Room
    Painting - Trailer Interior Spray Painting
    Paper and Leather Manufacturing - Paper Bleaching
    Paper and Leather Manufacturing - Paper Pulping
    Process Engineering - Air Cooled Mixer and Muller
    Process Engineering - Banbury Mixer
    Process Engineering - Bucket Elevator Ventilation
    Process Engineering - Mixer And Muller Hood
    Process Engineering - Roller Mill Ventilation
    Public Transportation - Bus Maintenance and Repair
    Public Transportation - Subway Maintenance and Repair
    Public Transportation - Train Maintenance and Repair
    Refineries and Energy - Renewable Energy Manufacturing
    Robotics and Artificial Intelligence - Robot Manufacturing
    The Art's - Cleaning with Solvents and VOC's
    Vehicle Repair Garage - Cars & Small Trucks Repair
    Vehicle Repair Garage - Diesel Engines Repair
    Vehicle Repair Garage - Service Garage Ventilation Overhead
    Vehicle Repair Garage - Truck Repair
    Waste Management - Vehicle Repair Garage
    Welding Shops - Steel Welding
    Woodworking - Wood Briquetting
    Woodworking - Wood Incineration