Lev-co
LEV-CO
182 N Port Road, Unit 3
Port Perry, Ontario L9L 0B7
App Support: 1-888-512-7173
Office: (905) 831-7001 / (888) 862-5356
Fax: (905) 831-7443 / (866) 885-1583
E-Mail: sales@lev-co.com
Model

02-023

Image for Mobi-Flex Blue.jpg

Roll-Flex-V - 1400 CFM

The "V" version of the ROLL FLEX filter is ideal for most VOC, ODOUR, and SPRAY painting applications. This Air Purifier comes complete with a 3 stage filter that includes an activated charcoal deep bed filter.

Function:

For the Roll-Flex-V, the air is pre-filtered with a washable particulate filter and then treated by either a single or dual stage, "gas phase" adsorption media filter. This solution is compact, very flexible and comes complete with a 7’ or 10' extraction arm.

Available Options:
  • Filter Options
  • 2nd Stage (Dual Pass) Gas Phase Filters
  • Custom Adsorption Media for Filtering Non-VOC Gases
  • Extension Hoods and Nozzles Options
  • Hazardous Locations Certification
  • Replacement Hoses
  • Variable Frequency Drives

Construction:

  • Powder-coated steel sheet
  • 1.1 kW Motor
  • 120 V/1/60, 2400 m³/hr. (1400 CFM)
  • Non-sparking aluminum impeller
  • All steel construction

This version of the Roll Flex comes standard with:
  • 4 Casters (2 swivel/lockable)
  • 1 Impingement Baffle
  • 1 High Capacity Washable Pre-Filter
  • 1 Metal Refillable Carbon Filter Module for 18 lbs. of Adsorption Media
  • Easy to Use Clean-Out Dust Tray
  • an ON/OFF Starter
  • Cable & plug

Shipping Dimensions and Weight:

Main System Part # Height x Width x Depth Weight
RF-V-7 39"H x 24"W x 42"D 220 lbs
RF-V-10 39"H x 24"W x 42"D 220 lbs

Key Buying Criteria:

  • 115 Volt Power: Ability to plug into any standard circuit while maximizing total flow rate and usage around the facility. (3-Phase voltage optional)
  • Small Footprint: Saves space in production area and speedy positioning by the operator. (22" x 24")
  • Complete, Pre-Engineered Unit: Guaranteed suitability. Versatile, easy to use, no installation required.
  • Spark Proof Direct-Drive Blower: Higher static pressure, longer filter life, and greater reliability. No wear items such as pulleys or belts to replace.
  • "Secure Seal" Filter Mounting: Eliminates contaminant bypass around filters.
  • Efficient Source Capture: 99.5% filter efficiency produces cleaner air.
  • Fire/Melt-proof Metal Construction: No plastic structure. Avoids high priced replacement costs.
  • Integrated Spark Deflector: Reduces fire risk in high sparking applications.
  • Vibra-Pulse® Filter Cleaning System: Cleans filters 75% more effectively than reverse pulse systems.
  • Low Profile Cabinet: Low center of gravity for easy maneuverability and arm positioning.
  • Cleanable Main Filter: Reduces operating costs.

Suitable For:

Top 5 contaminants/processes/applications:

  • VOC's
  • Paint Fumes
  • Spray Balms
  • Odours
  • Organic Vapours
Don't see your contaminants? Give us a call at 1-888-862-5356 or email us at sales@lev-co.com!

IMPORTANT: For your Health and Safety, make sure to talk to an application engineer before purchasing.
Part # Qty Description
RF-V-10 Self-Cleaning ROLL FLEX cartridge filter; 1.1 kw (1.5hp), 120 V, 1400 CFM
  • Complete with 3m (10') Extraction Arm
AS PER CANADIAN LAW; this unit is electrically approved by CSA/ESA field evaluation.
RF-V-7 Self-Cleaning ROLL FLEX cartridge filter; 1.1 kw (1.5hp), 120 V, 1400 CFM.
  • Complete with 2m (7') Extraction Arm
AS PER CANADIAN LAW; this unit is electrically approved by CSA/ESA field evaluation

Frequently bought together these options:

Part # Qty Description
H-SP-PA-200 Light-weight spray paint hood
  • Galvanized 28ga construction
  • Cardboard paint arrester
  • Used with 8" (200mm) Extraction Arm
H-SP-PA-QC Light-weight spray paint hood
  • Galvanized 28ga construction
  • Cardboard paint arrester
  • Used with P-003 extraction Arm
  • Quick connect version with bungee attachment
Part # Qty Description
SCF-C-20 Deep Bed Absorption module for SCF filter units (RF-SCF & DC-SCF).
  • Comes complete with 20 lbs. of activated carbon
  • Other adsorption media are available
Part # Qty Description
P-018-160-2MAG 10' long 6.33" (160mm), 250° hose, hood, & (2) magnets.
P-018-200-2MAG Extension hose for welding, 10' long 8" (200mm), 250° hose, hood, & (2) magnets.
RELH-160/200 **DISCONTINUED** Extension/receiving Bell Mouth hood connects directly to the hood on all flexi series extraction arms. Conical hood extension (6" or 8" dia. inlet) 24" outside diameter,. 18G, Aluminum.
SM-200 Safety mesh for Flexi Extraction Arms & P-Max Fans.
Part # Qty Description
Roll Flex V-LAB Labour required to install carbon filter & other alterations & inspections.
Part # Qty Description
CHARCOAL-15 15 lbs. Bag of non-recycled coconut shell-based activated carbon.
CHARCOAL-40 40 lbs. of non-recycled coconut shell-based activated charcoal.
P-004-WFC-12 Combo Filter. Spun bond polyester Pre-filter and Deep Bed activated carbon (holds approx. 15 lbs.) 11.5" (290mm) deep.
P-004-WFC-12-EXT Combo Filter. Spun bond polyester Pre-filter and Deep Bed activated carbon (holds approx. 15 lbs.) 11.5" (290mm) deep.
  • WITH external pre-filter wrapped on the outside of the filter
Get My Instant Quote
Ext.

Technical Info Requested

This site is protected by reCAPTCHA Enterprise and the Google Privacy Policy and Terms of Service apply.