model_icon
(13-05) Wall Fan - General Ventilation - Horizontal Discharge - (1,400 - 5,500 CFM)**
Model LAX1V fans are sturdily constructed, direct drive, horizontal discharge for industrial, commercial and farm applications. Suitable for general ventilation of factories, garages, warehouses, and other commercial and industrial buildings.
STANDARD FEATURES:
  • Built-in shutters that automatically open when the fan starts and gravity closes when the fan stops
  • heavy duty aluminum housing
  • Plated steel OSHA motor mount/guard
  • Single or variable speed operation
  • Aluminum fan blades on steel hub
  • Totally enclosed motors
  • Do you need a BUDGETARY estimate?

    Scroll down and select the products using the "Qty" boxes when completing the form below.
    If available, please email me...

    To make sure that you are a human being and not a robot, please also enter the security word you see on the right in the box:
    Shutter mounted axial fans (Motor Starter not included)
    Part # Qty  Description
    LAX12-1V 1/4HP 1700RPM fan
    Model LAX1V fans are sturdily constructed, direct drive, horizontal discharge for industrial,
    commercial and farm applications. Suitable for general ventilation of factories, garages,
    warehouses and other commercial and industrial buildings.
    Standard Features
    - Aluminum housing
    - Plated steel OSHA motor mount/guard
    - Single or variable speed operation
    - Aluminum fan blades on steel hub
    - Totally enclosed motors
    LAX14-1V 1/4HP 1700RPM fan
    Model LAX1V fans are sturdily constructed, direct drive, horizontal discharge for industrial,
    commercial and farm applications. Suitable for general ventilation of factories, garages,
    warehouses and other commercial and industrial buildings.
    Standard Features
    - Aluminum housing
    - Plated steel OSHA motor mount/guard
    - Single or variable speed operation
    - Aluminum fan blades on steel hub
    - Totally enclosed motors
    LAX16-1V 1/4HP 1700RPM fan
    Model LAX1V fans are sturdily constructed, direct drive, horizontal discharge for industrial,
    commercial and farm applications. Suitable for general ventilation of factories, garages,
    warehouses and other commercial and industrial buildings.
    Standard Features
    - Aluminum housing
    - Plated steel OSHA motor mount/guard
    - Single or variable speed operation
    - Aluminum fan blades on steel hub
    - Back draft dampers - Totally enclosed motors
    LAX18-1V 1/4HP 1700RPM fan
    Model LAX1V fans are sturdily constructed, direct drive, horizontal discharge for industrial,
    commercial and farm applications. Suitable for general ventilation of factories, garages,
    warehouses and other commercial and industrial buildings.
    Standard Features
    - Aluminum housing
    - Plated steel OSHA motor mount/guard
    - Single or variable speed operation
    - Aluminum fan blades on steel hub
    - Totally enclosed motors
    LAX20-1V 1/3HP 115/230 Volt 1 Phase 1700RPM fan
    Model LAX1V fans are sturdily constructed, direct drive, horizontal discharge for industrial,
    commercial and farm applications. Suitable for general ventilation of factories, garages,
    warehouses and other commercial and industrial buildings.
    Standard Features
    - Aluminum housing
    - Plated steel OSHA motor mount/guard
    - Single or variable speed operation
    - Aluminum fan blades on steel hub
    - Totally enclosed motors
    LAX24-1V 1/3HP 1700RPM fan
    Model LAX1V fans are sturdily constructed, direct drive, horizontal discharge for industrial,
    commercial and farm applications. Suitable for general ventilation of factories, garages,
    warehouses and other commercial and industrial buildings.
    Standard Features
    - Aluminum housing
    - Plated steel OSHA motor mount/guard
    - Single or variable speed operation
    - Aluminum fan blades on steel hub
    - Totally enclosed motors
    Safety Shields and Guards
    Part # Qty  Description
    LAX12-1V-FR-G Front guard for LAX12-1V fan.
    LAX14-1V-FR-G Front guard for LAX14-1V fan.
    LAX16-1V-FR-G Front guard for LAX16-1V fan.
    LAX18-1V-FR-G Front guard for LAX18-1V fan.
    LAX20-1V-FR-G Front guard for LAX20-1V fan.
    LAX24-1V-FR-G Front guard for LAX24-1V fan.
    Weather Guards and Options
    Part # Qty  Description
    LAX12-1V-GWH Galvanized weather hood for LAX-12-1V fan.
    LAX14-1V-GWH Galvanized weather hood for LAX-14-1V fan.
    LAX16-1V-GWH Galvanized weather hood for LAX-16-1V fan.
    LAX18-1V-GWH Galvanized weather hood for LAX-18-1V fan.
    LAX20-1V-GWH Galvanized weather hood for LAX-20-1V fan.
    LAX24-1V-GWH Galvanized weather hood for LAX-24-1V fan.
    Backdraft and Blow back Dampers
    Part # Qty  Description
    LAX12-1V-BD-DAMP Back Draft Damper for LAX12-1V fan.
    LAX14-1V-BD-DAMP Back Draft Damper for LAX14-1V fan.
    LAX16-1V-BD-DAMP Back Draft Damper for LAX16-1V fan.
    LAX18-1V-BD-DAMP Back Draft Damper for LAX18-1V fan.
    LAX20-1V-BD-DAMP Back Draft Damper for LAX20-1V fan.
    LAX24-1V-BD-DAMP Back Draft Damper for LAX24-1V fan.
    Carbon Monoxide and Nitrogen Dioxide Controls
    Part # Qty  Description
    AX-CMD Carbon monoxide detector for LAX series fans.
    AX-NO2 NO2 detector, 5%, 0-10 ppm, 3 wire, 4-20 mA output & adjustable relay.
    Temperature Controls
    Part # Qty  Description
    TH-RANCO-SINGLE Single stage RANCO waterproof thermostat.
    TH-RANCO-TWO Two stage RANCO waterproof thermostat.
    TH-SUNNE Single stage thermostat for heating or cooling. NEMA 4 enclosure.
    Speed and Flow Controls
    Part # Qty  Description
    SP-VFD-CTRL Speed control
  • Works with all AX series fans.
  • Pressure Controls
    Part # Qty  Description
    AX-ELP-20WS The Low Pressure Transmitter series is used to measure positive, negative or differential pressure. The piezoresistive sensor is ideal for monitoring the pressure of air or other clean inert gas. Typical HVAC applications include monitoring of filter differential pressure or VAV applications. An integrated static pressure probe provides ease of installation for duct mounting. Several accessories are available. A weatherproof polycarbonate enclosure is provided for electrical connections and ease of installation.
    AX-ELP-20WX The Low Pressure Transmitter series is used to measure positive, negative or differential pressure. The piezoresistive sensor is ideal for monitoring the pressure of air or other clean inert gas. Typical HVAC applications include monitoring of filter differential pressure or VAV applications. An integrated static pressure probe provides ease of installation for duct mounting. Several accessories are available. A weatherproof polycarbonate enclosure is provided for electrical connections and ease of installation.
    AX-ELP-5WS The Low Pressure Transmitter series is used to measure positive, negative or differential pressure. The piezoresistive sensor is ideal for monitoring the pressure of air or other clean inert gas. Typical HVAC applications include monitoring of filter differential pressure or VAV applications. An integrated static pressure probe provides ease of installation for duct mounting. Several accessories are available. A weatherproof polycarbonate enclosure is provided for electrical connections and ease of installation.
    AX-ELP-5WX The Low Pressure Transmitter series is used to measure positive, negative or differential pressure. The piezoresistive sensor is ideal for monitoring the pressure of air or other clean inert gas. Typical HVAC applications include monitoring of filter differential pressure or VAV applications. An integrated static pressure probe provides ease of installation for duct mounting. Several accessories are available. A weatherproof polycarbonate enclosure is provided for electrical connections and ease of installation.
    Controls
    Part # Qty  Description
    AX-PMRMC The PMRMC Particulate Matter Sensor uses an optical sensor based on laser scattering principles and features innovative contamination resistance technology to perform highly accurate and reliable PM measurements. The replaceable sensor measures particles of PM2.5 and PM10, with a continuousoperation lifetime of more than 8 years, The sensor will provide long-term reliability and high resolution particle size binning for the detection of environmental dust and other particles.
    D-SW Disconnect Switch.
  • Works with all LAX series fans
  • TH-CTRL Thermal control
  • Works with all LAX series fans
  • - Installation Accessories
    Part # Qty  Description
    P-CLIP-2.5 2.5 inch P Clips to hold 11.75 x 11.75 filters in hood
    P-CLIP-4.5 WIRING PIGTAIL & mounting Bracket.4.5 L
    PRF-6-01 Main part for Pre-Filter holder
    Viledon-Media Roll of Viledon Filter media 7x7