Model

05-006

ALH1 - 5.3FT ² CAPTURE AREA

ALH1 - A self-contained Downdraft table that meets NFPA 651 standard for processing and finishing aluminum With a max flow rate of 800 CFM to 1,700 CFM

Function:

Features a work surface that draws contaminants away from workers' breathing zone without hindering the worker's movement.

The table offers a Direct-Drive Blower, Non-electrostatic Operation, an Ultra-Seal® Filter Mounting, Optional Casters and an Ergonomic Cabinet. The electrical also meets the standards of NFPA Division II with group-E for aluminum dust.

Available with:
  • Filter Options
  • Localized Enclosures and Shields
  • Silencer Option
  • VFD Options
  • Fan/Motor Upgrades or Options
  • Preventative Maintenance Pressure Gauges

Construction:

  • 12, 14, and 16 gauge welded steel cabinet with powder-coat finish
  • Includes removable end cap for easy access to the filter
  • Removable back panel for access to direct drive motor/blower compartment
  • Removable 5-gallon external dust drawer
  • 8” front wheels with 5” rear swivel casters
  • 12 gauge power cord
  • On-off switch for 115V units
  • 1 phase and 3 phase units are wired to a side junction box. (Motor starter not included.)
  • Different sizes are: 24''D X 32’’W (800 CFM); 24''D X 48’’W (1700)

Shipping Dimensions and Weight:

Main System Part # Height x Width x Depth Weight
ALH1-3 "H x "W x "D 0 lbs
ALH1-2 "H x "W x "D 0 lbs
ALH1-1 80"H x 55"W x 41"D 425 lbs

Key Buying Criteria:

  • Integral collection area and work surface: Draws contaminants away from workers’ breathing zone without hindering movement; easily moved to any location in the facility.
  • Direct-Drive Blower: Higher static pressure, longer filter life and greater reliability; spark resistant; no belts or pulleys to replace.
  • Non-electrostatic operation: High reliability, low maintenance.
  • Explosion Proof Fan: Safe for mounting in explosive environments (Requires optional Hazardous location Certification)
  • Low profile cabinet Easy access speeds filter changeout and maintenance.
  • Vibra-Pulse® Filter Cleaning System: Cleans filters 75% more effectively than reverse pulse systems.
  • Dust Drawer: Easily remove external dust drawer with positive lever lock.

Suitable For:

Top 5 contaminants/processes/applications:

  • Large Particle Aluminum dust (with a K factor below 100)
  • VOC Fumes
  • Composite Dust
  • Deburring Dust
  • Grinding Particles
Don't see your contaminants? Give us a call at 1-888-862-5356 or email us at sales@lev-co.com!

IMPORTANT: For your Health and Safety, make sure to talk to an application engineer before purchasing.
Part # Qty Description
ALH1-1 800 cfm portable downdraft table to collect aluminum dust:
  • 24" deep x 32" wide work surface at 36.25" height
  • 150 fpm downdraft velocity
  • 12" tall aluminum side & back shields with aluminum grate panels
  • Contains (1) ULTRACLEAN-PLUS ™ cartridge filter (150 sq.ft.) & a 1 HP Class II, Group E motor. 115/230/1/60 Hz (12/6 amps)
  • Electrical components meet NFPA requirements for Class II, Group-E. (ALUMINUM DUST). 71 dBA.
AS PER CANADIAN LAW; this unit is electrically approved by CSA/ESA field evaluation.
ALH1-2 800 cfm portable downdraft table to collect ALUMINUM DUST:
  • 24" deep x 32" wide work surface at 36.25" height
  • 150 fpm downdraft velocity, with 12" tall aluminum side & back shields with aluminum grate panels
  • Contains (1) ULTRACLEAN-PLUS ™ cartridge filter (150 sq.ft.)
  • 1 Hp Class II, Group E motor. 230/460/3/60 Hz (12/6 amps)
  • Electrical components meet NFPA requirements for Class II, Group-E. (ALUMINUM DUST). 71 dBA
AS PER CANADIAN LAW; this unit is electrically approved by CSA/ESA field evaluation.
ALH1-3 800 cfm portable downdraft table to collect aluminum dust:
  • 24" deep x 32" wide work surface at 36.25" height
  • 150 fpm downdraft velocity, with 12" tall aluminum side & back shields with aluminum grate panels
  • Contains (1) ULTRACLEAN-PLUS ™ cartridge filter. (150 sq.ft.)
  • 1 Hp Class II, Group E motor. 5753/60 Hz (12/6 amps)
  • Electrical components meet NFPA requirements for Class II, Group-E. (ALUMINUM DUST). 71 dBA.
AS PER CANADIAN LAW; this unit is electrically approved by CSA/ESA field evaluation.

Frequently bought together these options:

Part # Qty Description
ALH-1-EXAD External AD Module Filter Option for Standard ALH-1 Unit.
ALH-1-EXDOP External 95% DOP Filter Option for Standard ALH-1 Unit.
ALH-1-EXHE External 99.97% HEPA Filter Option for Standard ALH-1 Unit.
ALH-1-EXT HE/AD Kit using EXTERNAL HEPA and EXTERNAL AD options.
Part # Qty Description
ALH-1-BF3A Aluminum Enclosure, 36 High, Sides, Back & Top Option for Standard ALH-1 Unit.
Part # Qty Description
ALH-1-HP-3 1.5 Hp Hazardous Location, Class II, Grp E 208-208/460/3/60 Option for Standard ALH-1 Unit.
Part # Qty Description
ALH-1-S-EXT External Silencer Option for Standard ALH-1 Unit.
Part # Qty Description
ALH-1-PG-6 0-6" Magnahelic pressure gauge, approximately 5" (125mm)Ø size.
  • Surface mounted
Part # Qty Description
2KT6-1760-ALH1 Table extension painted blue for ALH-1, full width with solid surface, 9" (230mm) deep.
Part # Qty Description
2FR5-1001 Cartridge, AD, refillable with 1" (25mm) pre-filter pad & 1" (25mm) after-filter pad.
  • Holds 15 lbs. of charcoal
ALH-1-FIBER Fiberglass Bar Grate Option for Standard ALH-1 Unit
ALH-1-PG-5 0-5" Magnahelic pressure gauge, approximately 5" (125mm)Ø size.
  • Surface mounted
Part # Qty Description
1PN6-1749 Aluminum Grate Panels. Price per each (6 required for DTH800) DUSTPAK ALH-1, DUSTPAK ALH-2, DUSTPAK AL-6, DUSTPAK DTH-800, (9 required for DUSTPAK DTH-1700.)
2AF2-0011 2" (50mm) Polyester Frame & Pad.
2AF9-0001 Adsorber module, flat, refillable. (18" x 24" x 2½").
  • Holds 18 lbs. of charcoal
  • Charcoal sold separately
7FJ9-5003 95% @ 0.3 microns DOP Filter for PCH/DCH/DTH/ALH units.
7FJ9-9003 99.97% @ 0.3 microns HEPA Filter for PCH/DCH/DTH/ALH units - METAL FRAME.
7FJ9-9003-W 99.97% @ 0.3 microns HEPA Filter for PCH/DCH/DTH/ALH units - WOOD FRAME.
7FR0-5020 OEM Cartridge Filter ALH-1/2/6 filter used in explosive & flammable applications such as aluminum dust applications.
Get My Instant Quote
Ext.

Technical Info Requested

This site is protected by reCAPTCHA Enterprise and the Google Privacy Policy and Terms of Service apply.