model_icon
(11-09) NOMEX - Ducted - Suitable for most Wet/Dry particulate or gas phase contaminants **
The NOMEX© filter boasts a high degree of separation… When used for oil mists the Nomex boasts a 95% efficiency on oil mists and up to 99.9% of particulates. The Nomex is also well suited to handle Gas Phase applications with the use of activated media modules. The oil mist filters are considered "life-time" that last a minimum of 5 years while the activated media needs to be changed out (Refilled) when the media becomes saturated.
CONSTRUCTION:

Filter housings are equipped with either deep pleated glass fiber medium and aluminum separators or Gas Phase filter modules. Complete unit fabricated from 16 ga. powder-coated steel sheet with filter boxes, Optional HEPA and other PRE and AFTER filters available upon request. Systems include: pre-engineered spark resistant fan, VFD rated TEFC motor*, 3 pressure gauges p, 3 inlet directions and drain pipes in 2 direction (1” outside thread). * "Washdown" and "Explosion proof" motors available as options

Do you need a BUDGETARY estimate?

Scroll down and select the products using the "Qty" boxes when completing the form below.
If available, please email me...

To make sure that you are a human being and not a robot, please also enter the security word you see on the right in the box:
Main System / Part
Part # Qty  Description
NX-1000-1 NOMEX© 1000 mechanical oilmist filter 600 CFM c/w 1.5 HP 115/1/60 motor and one (1) washable filter box. An OPTIONAL HEPA afterfilter (99.99%) not washable available. Inlet 160mm (6.5”) Ø.
NX-2000-1 NOMEX© 2000 mechanical oilmist filter 2000 M3H c/w 3 HP 208-230V/460V/3/60 motor and two (2) washable filter box. An OPTIONAL HEPA afterfilter (99.99%) not washable available. Inlet 200mm (8”) Ø.
NX-4000-1 NOMEX© 4000 mechanical oilmist filter 4000 M3/H (2400 CFM) c/w 5 HP 208-230V/460V/3/60 motor and two (2) washable filters. An OPTIONAL HEPA afterfilter (99.99%) not washable available. Inlet 315mm (12”) Ø.
NX-4000-2 NOMEX© 4000 mechanical oil mist filter 4000 M3/H (2400 CFM) c/w 5 HP 575-600V/3/60 motor and two (2) washable filters. An OPTIONAL HEPA afterfilter (99.99%) not washable available. Inlet 315mm (12”) Ø.
Filter Options (when ordering with main unit)
Part # Qty  Description
CFH-R-40 Carbon Filter Holder. Holds 40 lbs. of activated carbon.
  • activated carbon not included.
  • NX-1200-HEPA HEPA Filter Option ( 99.99%) for NOMEX© 1200. Not washable.
  • Replacement filter
  • NX-2400-4000-HEPA HEPA Filter Option ( 99.99%) for NOMEX© 2400. Not washable.
  • Replacement filter
  • NX-266 HEPA Filter Option (99.99%) for Nomex 4000 - 48m2
  • Replacement filter
  • NX-600-HEPA HEPA Filter Option ( 99.99%) for NOMEX© 600. Not washable.
  • Replacement filter
  • P-264 HEPA Filter Option (99.99%) for Nomex 1000/2000- 24 m2
  • Replacement filter
  • P-265 HEPA Filter Option (99.99%) for Nomex 4000 - 24m²
  • Replacement filter
  • Variable Frequency Drives
    Part # Qty  Description
    VFD-KIT-1HP-115-230-3 1HP 120-240V Hybrid VFD 1 Phase In, 230V 3 Phase Output 60Hz complete with:

  • VFD NEMA 4
  • 1 HP Motor
  • Wiring
  • Labor
  • Re-certification

  • PLEASE NOTE: this kit is only required when upgrading a 120V system with a VFD
  • VFD-KIT-2HP-115-230-3 2HP 120-240V Hybrid VFD 1 Phase In, 230V 3 Phase Output 60Hz complete with:

  • VFD NEMA 4
  • 2 HP Motor
  • Wiring
  • Labor
  • Re-certification

  • PLEASE NOTE: this kit is only required when upgrading a 120 or 220/1/60 V system with a VFD
  • VFD-KIT-3HP-220-230-3 3HP 240V Hybrid VFD 1 Phase In, 230V 3 Phase Output 60Hz complete with:

  • VFD NEMA 4
  • 3 HP Motor
  • Wiring
  • Labor
  • Re-certification

  • PLEASE NOTE: this kit is only required when upgrading a 120V system with a VFD
  • Inlet Filter (Also commonly reffered to as a 'Pre-filter')
    Part # Qty  Description
    NX-OMA-04 Prefilter - Oil Mist Accumulator - Ø4 Dia Inlet & Outlet
    NX-OMA-05 Prefilter - Oil Mist Accumulator - Ø5 Dia Inlet & Outlet
    NX-OMA-06 Prefilter - Oil Mist Accumulator - Ø6 Dia Inlet & Outlet
    NX-OMA-07 Prefilter - Oil Mist Accumulator - Ø7 Dia Inlet & Outlet
    NX-OMA-08 Prefilter - Oil Mist Accumulator - Ø8 Dia Inlet & Outlet
    NX-OMA-09 Prefilter - Oil Mist Accumulator - Ø9 Dia Inlet & Outlet
    NX-OMA-10 Prefilter - Oil Mist Accumulator - Ø10 Dia Inlet & Outlet
    NX-OMA-11 Prefilter - Oil Mist Accumulator - Ø11 Dia Inlet & Outlet
    NX-OMA-12 Prefilter - Oil Mist Accumulator - Ø12 Dia Inlet & Outlet
    Misc. Options (when ordering main unit)
    Part # Qty  Description
    OM-134-10 Hood handle for Pro-Flex and Flexi
    Hazardous location certifications and accessories
    Part # Qty  Description
    HAZLOC-CERT Hazardous Location Certification for equipment use in Class 1 Division 2. To include but not limited to the following:

    Hazardous location equipment Labeling

  • Approval Report
  • Certification Sticker
  • Preventative Maintenance Pressure Gauges, etc. (when ordering main unit)
    Part # Qty  Description
    LEV-MC-PG-5 Pressure Gauge - complete with Wall, Ceiling or table mounting bracket and 0-5 pressure gauge. 3/16 inside diameter tubing ordered separately.
    PG-10 Pressure Gauge - complete with Wall, Ceiling or table mounting bracket and 0-10 pressure gauge. 3/16 inside diameter tubing ordered separately.
    Replacement filters - (Quantity discounts available upon request)
    Part # Qty  Description
    7FJ9-5112 95% @ 0.3 micron DOP filter c/w metal frame, 72 Deep
    7FJ9-9005 99.97% @ 0.3 micron Mini Pleat 1500 CFM MERV 17 HEPA Filter for MP-30/60/120, F-120/122/240/360/480/, 202, 203, Mistpak Pro 2/3/4, Panel Filter Booth, Dustron Panel Booth, & Air Pod
    7FP1-1412 Mid-Efficiency Filter for Pac-91, MP-30/60/120, F-120/122/240/360/480/, 202, 203, Mistpak Pro 2/3/4, Panel Filter Booth, Dustron Panel Booth, Easy Bench & Air Pod. 24"x24"x4"
    7FP1-4505-P High Efficiency Filter for Pac-91, MP-30/60/120, F-120/122/240/360/480/, 202, 203, Mistpak Pro 2/3/4, Panel Filter Booth, Dustron Panel Booth, Easy Bench & Air Pod. 24"X24X"4"
    CHARCOAL-CP40 40 lb of CP Blend of chemisorbant and activated carbon blend.

  • Target Contaminants:
  • Hydrocarbons
  • VOC's
  • Oxides of sulfur
  • Formaldehyde
  • Nitric Oxide
  • Hydrogen Sulfide
  • Lower molecular weight aldehydes and organic acids
  • NX-1200-RF-1 Stage 1-Replacement Filter for NOMEX© 1200.
    NX-1200-RF-2 Stage 2-Replacement Filter for NOMEX© 1200.
    NX-4000-RF-1 Stage 1-Replacement Filter for NOMEX© 4000.
    NX-4000-RF-2 Stage 2-Replacement Filter for MULTIFLEX & NOMEX© 4000.
    NX-600-RF Replacement Filter for Nomex 600.
    P-318 Replacement Filter-box for Nomex 1000/2000, washable, 12m2 (258 sq. ft.)
    P-319 Replacement Filter-box for Nomex 2000, washable, 16m2 (387 sq. ft.) .
    P-320 Stage 1 Replacement Filter-box for Nomex 4000, washable, 24m2+24m2 (258 sq.ft.+258 sq.ft)
    P-321 Stage 2 Replacement Filter-box for Nomex 4000, washable, 32m2 (387 sq.ft.)